Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAdmitted-Finance INDUSTRIAL ESTATE DIGIANA JAMMU | L1 | Admitted-Finance | |
| 2 | L2₹4.7 L+₹497 (0.11%)Admitted-Finance BHAGWATI NAGAR JAMMU | L2 | Admitted-Finance | |
| 3 | L3₹4.8 L+₹13,000 (2.80%)Admitted-Finance 37 B PHASE 3 INDUSTRIAL ESTATE GANGYAL JAMMU | L3 | Admitted-Finance | |
| 4 | L4₹5 L+₹35,100 (7.55%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹6.0 L+₹1.3 L (28.4%)Admitted-Finance 183 ONKARESHWAR COLONY KADAM VIHAR MATHURA MATHURA UTTAR PRADESH 281006 | MATHURA | UTTAR PRADESH | 281006 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Jay Pee and Sons L4 | M/S V.N ENGG WORKS L1 | M/S K S ENGG WORKS L3 | PERFECT ELECTRICAL WORKS L2 | M/S BHARAT ENGINEERING COMPANY L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing, Lowering, Installation, Testing and Commissioning of Submersible Pumpset at Tubewell mentioned above having capacity of (15,000 GPH) x (40m Head) coupled with 3 phase 380 Volts + 10%, 50 Hz ± 3% AC supply, copper wound squirrel cage induction submersible motor of20 H.P. along with 10 No. 100mm dia flanged column pipes assembly and other allied materials/equipments required during lowering of submersible pumpset. The job also includes P/L of 30 mtr-35 mm sq. 3.5 core aluminum armored cable for connection of control panel to electric transformer and 90 mtr-10 mm sq 3 core submersible cable for connection of panel to the submersible pumpset. The job also includes P/F of 100 mm dia90 degree flanged M.S. bend. The job also includes P/F of 3mtr 100 mm dia flanged G.I. delivery pipe along with Sluice and Non ReturnValve. The job also includes providing and fitting of 200 Amp, 415 Volt main switch with HRC Fuse of reputed make. The job includes cost of material, labour, carriage, tools and tackles (Complete Job in all respects). Electro-mechanical accessories used should be of genuine/reputed make conforming to latest IS code. | 1 | Job | 2,50,000 ₹2,50,000 | 2,39,900 ₹2,39,900 | 2,35,000 ₹2,35,000 | 2,30,999 ₹2,30,999 Lowest | 3,62,500 ₹3,62,500 |
| 2.00 | Design, fabrication, installation, testing and commissioning of ElectricControl Panel with built in fault analyzer suitable for running 20 H.P.Submersible Pumpset. The panel should be dust and vermin proof fabricated out of 14/16 SWG CR sheet and provision for fixing it on the wall or the ground with the help of anchoring bolts should be made. The Panel should be sturdy enough for vibration free operation and should be equipped with suitable locking / sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel is to be given two coats of anti-rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: -
1. The panel should be fitted with 100 Amps MCCB and a set of RYB indicators at incoming side.
2. Star delta starter: - The panel should be fitted with 01 No. star delta starter comprising of 01 No. 40 Amps. contactor for main supply,01 No. 40 Amps. contactor for delta supply and 01 No. Air break40 Amps.contactor for star operation, 01 No. timer for changing over the supply of motor from star to delta, 02 No.s push buttons for start and stop operation of motor. 01 No. MCB 10 Amps. for the protection of internal control wiring. A neat and clean internal control wiring should be made with flexible, copper cables to complete the star delta circuit of outgoing supply.
3. Protection device: - The panel is fitted with protection devices like relay, CT/PT, timer, fault analyzer with capacity to protect motor by isolating the power supply of motor de-energizing the starter/ panel from electro-mechanical faults which may otherwise damage the motor windings like single phasing, under voltage, over voltage, unbalanced voltage, reverse phasing, over current / over load, unbalanced current / load, short circuiting.
The panel shall also be provided with ammeter and voltmeter of appropriate capacity. All the equipments used i.e. contactors, relays, MCCB etc. used should be of standard make. | 1 | Job | 70,000 ₹70,000 | 75,000 ₹75,000 | 65,000 ₹65,000 | 82,399 ₹82,399 | 58,900 ₹58,900 Lowest |
| 3.00 | Providing, installation, testing and commissioning of 63 kVA copper wound, oil cooled, manually operated voltage stabilizer with input voltage range (160 V to 400 V) and output voltage range (400V ± 10%) and frequency 50 Hz ± 3% for irrigation Tubewell. The stabilizer should be mounted on unidirectional wheels. The stabilizer assembly should comprise of core made of silicon steel wound with copper coil conductor of appropriate quality confirming to BIS with di-electric oil of proper value for cooling stabilizer assembly. The job also includes P/F 01 No. changeover/by-pass switch of 100 Amps for by-passing the voltage regulation mechanism andto run the system on main incoming supply in case there is a problem in voltage stabilizer. The job also includes P/F of 01 No. 100 Amp M.C.C.B. on output side & other required fittings. The job also includes providing and laying of 16 mm sq. multi strand single core copper cable as per site requirement for making connection of Voltage Stabilizer to Electric Control Panel after thimbling the cable ends. The job includes cost of material, labour, carriage, tools and tackles. | 1 | Job | 1,80,000 ₹1,80,000 | 1,50,000 ₹1,50,000 Lowest | 1,77,900 ₹1,77,900 | 1,51,999 ₹1,51,999 | 1,75,600 ₹1,75,600 |
Tender Value
₹6.0 L
EMD Value
₹12,040
Closing Date
7 Oct 2025, 2:00 pmClosed
XEN Tube WEll Irrigation DIv Jammu
XEN Tube WEll Irrigation DIv Jammu
Providing Fitting Replacement of existing machinery with New Submersible Pumpset 15000 GPH X 40 m Head 20 HP induction motor Voltage Stabilizer 63 kVA and Electric Control Panel 20 HP 3 Phase Star Delta at Tube well Bulla chak B1
2025_IFC_289428_3
eNit no. 16of 2025-26
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
45 days
Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
XEN Tube WEll Irrigation DIv Jammu
₹12,040
Yes
23 Oct 2025
24 Sept 2025
8 Oct 2025
24 Sept 2025
7 Oct 2025
24 Sept 2025
Amount
Providing, Lowering, Installation, Testing and Commissioning of Submersible Pumpset at Tubewell mentioned above having capacity of (15,000 GPH) x (40m Head) coupled with 3 phase 380 Volts + 10%, 50 Hz ± 3% AC supply, copper wound squirrel cage induction submersible motor of20 H.P. along with 10 No. 100mm dia flanged column pipes assembly and other allied materials/equipments required during lowering of submersible pumpset. The job also includes P/L of 30 mtr-35 mm sq. 3.5 core aluminum armored cable for connection of control panel to electric transformer and 90 mtr-10 mm sq 3 core submersible cable for connection of panel to the submersible pumpset. The job also includes P/F of 100 mm dia90 degree flanged M.S. bend. The job also includes P/F of 3mtr 100 mm dia flanged G.I. delivery pipe along with Sluice and Non ReturnValve. The job also includes providing and fitting of 200 Amp, 415 Volt main switch with HRC Fuse of reputed make. The job includes cost of material, labour, carriage, tools and tackles (Complete Job in all respects). Electro-mechanical accessories used should be of genuine/reputed make conforming to latest IS code.
Design, fabrication, installation, testing and commissioning of ElectricControl Panel with built in fault analyzer suitable for running 20 H.P.Submersible Pumpset. The panel should be dust and vermin proof fabricated out of 14/16 SWG CR sheet and provision for fixing it on the wall or the ground with the help of anchoring bolts should be made. The Panel should be sturdy enough for vibration free operation and should be equipped with suitable locking / sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel is to be given two coats of anti-rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: - 1. The panel should be fitted with 100 Amps MCCB and a set of RYB indicators at incoming side. 2. Star delta starter: - The panel should be fitted with 01 No. star delta starter comprising of 01 No. 40 Amps. contactor for main supply,01 No. 40 Amps. contactor for delta supply and 01 No. Air break40 Amps.contactor for star operation, 01 No. timer for changing over the supply of motor from star to delta, 02 No.s push buttons for start and stop operation of motor. 01 No. MCB 10 Amps. for the protection of internal control wiring. A neat and clean internal control wiring should be made with flexible, copper cables to complete the star delta circuit of outgoing supply. 3. Protection device: - The panel is fitted with protection devices like relay, CT/PT, timer, fault analyzer with capacity to protect motor by isolating the power supply of motor de-energizing the starter/ panel from electro-mechanical faults which may otherwise damage the motor windings like single phasing, under voltage, over voltage, unbalanced voltage, reverse phasing, over current / over load, unbalanced current / load, short circuiting. The panel shall also be provided with ammeter and voltmeter of appropriate capacity. All the equipments used i.e. contactors, relays, MCCB etc. used should be of standard make.
Providing, installation, testing and commissioning of 63 kVA copper wound, oil cooled, manually operated voltage stabilizer with input voltage range (160 V to 400 V) and output voltage range (400V ± 10%) and frequency 50 Hz ± 3% for irrigation Tubewell. The stabilizer should be mounted on unidirectional wheels. The stabilizer assembly should comprise of core made of silicon steel wound with copper coil conductor of appropriate quality confirming to BIS with di-electric oil of proper value for cooling stabilizer assembly. The job also includes P/F 01 No. changeover/by-pass switch of 100 Amps for by-passing the voltage regulation mechanism andto run the system on main incoming supply in case there is a problem in voltage stabilizer. The job also includes P/F of 01 No. 100 Amp M.C.C.B. on output side & other required fittings. The job also includes providing and laying of 16 mm sq. multi strand single core copper cable as per site requirement for making connection of Voltage Stabilizer to Electric Control Panel after thimbling the cable ends. The job includes cost of material, labour, carriage, tools and tackles.
PERFECT ELECTRICAL WORKS (BID ID -2576078)
M/S K S ENGG WORKS (BID ID -2577935)
Jay Pee and Sons (BID ID -2571090)
M/S BHARAT ENGINEERING COMPANY (BID ID -2570678)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .