Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 CrAccepted-AOC AH 73 2 5TH STREET 7TH MAIN ROAD SHANTHI COLONY ANNA NAGAR CHENNAI 600 040 | CHENNAI | TAMIL NADU | 600040 | ₹11.3 Cr | L1 | Accepted-AOC The lowest and negotiated tenderer |
| 2 | L2₹11.3 CrRejected-Finance NO 1 PPS COMPLEX METTUR MAIN ROAD OMALUR TALUK SALEM 636455 | SALEM | SALEM | TAMIL NADU | 636455 | ₹11.3 Cr | L2 | Rejected-Finance High rate tenderer |
| 3 | L3₹11.3 CrRejected-Finance | ₹11.3 Cr | L3 | Rejected-Finance High rate tenderer |
| 4 | L4₹11.5 CrRejected-Finance | ₹11.5 Cr | L4 | Rejected-Finance High rate tenderer |
Tender Value
Refer Docs
EMD Value
₹6.7 L
Closing Date
27 Jan 2023, 6:00 pmClosed
Superintending Engineer / CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10.
Construction of Barracks at a capacity to accommodate 450 Police Personnel at Kilpauk Police Quarters, Kilpauk in Chennai city under Announcement made by the Honoroble Chief Minister of Tamil Nadu during the Police demand held on 13.09.2021
2023_TNPHC_281364_1
SE/CC/DB/3248/2021
Open Tender
Civil Works
330 days
Kilpauk in Chennai city
Construction of Barracks at a capacity to accommodate 450 Police Personnel at Kilpauk Police Quarters, Kilpauk in Chennai city under Announcement made by the Honoroble Chief Minister of Tamil Nadu during the Police demand held on 13.09.2021
8 documents required · 8 mandatory
₹0
₹6.7 L
25 Apr 2023
12 Jan 2023
30 Jan 2023
12 Jan 2023
27 Jan 2023
12 Jan 2023
Amount
1.1) Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
7.2) Supply and fixing of Bituminous filler pad, 20mm tk. for expansion joint
13.1) Filling with Excavated Earth
21.2) Teak wood Wrought & Put up a. T.W. over 2m & below 3m
b. T.W. below 2m length.
23.3) S & F of Magnetic door catches
25) M.S.Holdfast
30) Ellispattern
31) Weathering course
37.1) White washing 3coats (slaked)
39) M.s Grills
40) Painting - New "wood work"
41) Painting - New "iron work"
47) S & F Alu Towel rail 75 cm long
48) S & F 5 pin Coat stand
49) S & F chromium plated 8 gauge Picture Hook
50.3) Supply and planting avenue trees
50.4) Providing Tree guard
52.1) G.I Pipe 20mm dia for Hot water line (Fully Concealed in walls)
53.3) C.I. Steps ( 5 kg)
55.2) Flat Back Urinal
Electrical arrangements 72) Box type Fibre Fan hook
74) Charges for fixing of "Fan"
76) 8 SWG wire
77.3) S & F of TV/Telephone line Socket
77.4) S & F of 20mm dia PVC pipe for TV/Telephone line
78) Earthing Station IS3043 (Type I)
86) Anti termite treatment
112) S & F of Exhaust Fan 300 mm dia
238) Anticorrosive treatment for steel grills
ANNEXURE 1.9.3.5) Bored cast situ piles installation of vertical cast in Situ Bored piles of following dia using Standardised concrete Mix M30 Grade a). 600mm dia
1.9.4.1) Chipping of RCC pile head to the required cut of level and clearing away debries with an average lead of 3km a.) 600mm dia
1.9.5) Mobilization charges including transporting to site
1.9.6) Conducting routine vertical compression load test for bored cast in situ RCC piles of following dia a) 600mm dia
2.13) Supplying and filling with gravel
2.15) Supplying and filling stone dust
3.1.3) C.C.1:5:10 for Foundation & Basement
3.2.1) P.C.C. 1:2:4 for Foundation & Basement and other similar works
3.8.4) P.C.C. 1:4:8 using 40 mm broken HBS jelly
6.2.3) Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")
8.2.3.2) Standardised concrete Mix M30 Grade Concrete a. In Foundation and basement
b. In Ground Floor
c. In First Floor
d. In Second Floor
e. In Third floor
f. In Fourth floor
g. In Fifth floor
9.2.2) Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") a. In Ground Floor / Stilt floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
f. In Fifth floor
10.2.2) Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.) a. In Foundation and basement
b. In Ground Floor/stilt floor
c. In First Floor
d. In Second Floor
e. In Third Floor
f. In Fourth Floor
11.2.2) Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.) a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
e. In Fourth Floor
15.4.1) Cuddappa slab 20mm tk.for C/B slab. a. Ground floor
b. In First floor
c. In Second floor
d. In Third floor
e. In Fourth floor
15.5.1) Cuddappa slab 40mm tk.for C/B slab. a. In Ground floor
b. In First floor
c. In Second floor
d. In Third floor
e. In Fourth floor
18.1) Formwork using M.S.Sheet a.For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b.Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.Vertical wall
21.5.2.2) Supply and Fixing Solid UPVC door Shutter with frame
21.5.6.1) Supplying and fixing of solid core flush door shutter of thickness 35mm a). Door size 1.00 m x 2.10m (Single Leaf)
21.5.6.2) Supplying and fixing of solid core flush door shutter of thickness 35mm a) Door size 1.80m x 2.10m (Double leaves)
b). Door size 1.50m x 2.10m (Double leaves)
21.6.1.4) R.C.C.Door frames of size 100 x 75mm with one edge grooves size 't' x 20 mm using M30 grade (without vibrating charges) b). 1000 x 2100 mm
22.3.3) T.W. frame & TW styles & rails with BWR double leaf shutters for cup board/ ward robes including two coat enamel paint & one coat primer.
26.1) Flooring in C.C.1:5:10
29.8.1) Glazed tiles using Grout (Tile Joint Filler), C.M 1:2, 10mm tk
29.9.1) Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).
32.1.1) Pressed tiles (23cmx23cmx20mm) mixed with Water proofing compound
33.2) Plastering in C.M. 1:5, 12mm tk
34.2) Plastering in C.M. 1:4, 12 mm tk.
35.3) Spl. Ceiling plastering in C.M. 1:3, 10mm tk.
36.1) Cement mortar Border in C.M.1:5, 12mm tk. a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.6) One coat white cement for new walls and other similar works.
43.2.1) Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods. (Binding wire insulated with PVC)
44.2.1.1) Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M30)
b) Augering 30cm dia
44.6.1) PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe (UPVC special clamp)
45.2) Providing Colour Marble chips of size 10mm and below using 72Kgs of cement and 0.15 cum of Colour Marble chips for every 10 sqm over the existing plastered surface.
50.2.1) Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150 mm
50.5.1) Supplying, Fabricating and erection of M.S Scheme Name board
50.6.1) Precast slab 50mm tk.in C.C. 1:3:6 with fibre
51.9) Supplying and erecting in position of 50 litres capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver potable water.
52.1.1) Supply ,laying & jointing the following pipes as per ASTM D 1785 of schedule 40 with UPVC Specials (Above Ground level) a. 32 mm dia
b. 25 mm dia
52.1.2) Supply, laying, fixing and jointing the following UPVC pipes as per ASTM D-1785 of schedule a) 50 mm dia UPVC pipes (Below ground level)
52.1.3) Supply ,laying & jointing the following pipes as per UPVC pipes 1785 of schedule 40 with UPVC Specials b). 50 mm dia UPVC pipes (above ground level)
52.4) 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
52.9) Supplying and fixing of following dia MS clamp sets b) 50mm dia MS clamp set
53.4) S & F of C.I Manhole cover 60x 60cm (50kg weight )
53.5) Wash Hand Basin of size 550 x 400mm (White without Pedestal)
54.1.1) S & F of 15mm dia half turn CP long body tap
54.2.1) S & F of 15mm dia half turn CP short body tap
56.3.2) S & F of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap - in G.F.
56.4.2) S & F of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap- Other than G.F.
57.1.1) S & F of E.W.C.(White) 500 mm with PVC SWR grade "P" or "S" TRAP
58.3) PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4) Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
59.2.1) Gully Trap using chamber burnt bricks of size 23x11.4x7.5cm
60.1) PVC Nahani trap (4way/2way)
61.3) UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110mm UPVC Non Pressure pipe
b. 160mm UPVC Non Pressure pipe
64.1.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. (PVC Box, Fire Retarded Box) a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point. (PVC Electrical Box )
66.1.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point. (PVC Electrical Box )
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS:694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS:694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.(PVC Electrical Box )
68.3.2) Wiring for lift well light point and socket outlet with 2 x 1.5 sqmm FRLS PVC insulated stranded copper conductor of 1100V grade along with 1 x 1.5 sqmm FRLS PVC insulated stranded copper conductor cable
69.2) Supplying and fixing of 15 Amps 3 pin flush type plug using ( PVC Box, Fire Retarded Box)
75.2) Supply and delivery of 48" (1200 mm) Fan with ISI mark with Electronic Dimmer
77.5) Run off 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7) Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
78.4) Earthing as per the ISI specification with an earth electrode of 2.1mtr class 'B' GI pipe of dia not less than 40mm.
82.3) Supply and fixing of LED road way lightiing luminaries b) 30W LED lamp
84.3) Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
88.1.1) Providing Shahabad stone slab flooring, C.M 1:3, 20mm tk
93.1.1) Plastering with CM 1:3, 12mm with WPC
96.2.7) Supply and Laying Rubber Moulded Hydraulic Pressed Paver Block 83 mm thick including labour charges for laying.
107.3) Run off 4 Wires of 10 sqmm PVC insulated single core multi strand
144.2.1) Supplying and fixing of 250 Watts Metal halide Flood light.
156.2.1) Supply and erection of 125 Amps capacity panel board (Cubical type) with bus bar
156.4) Supply and erection of 250 amps capacity (cubical type) panel board
171.1.2) Labour charges for the erection of submersible pumpset in borewell/ openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth. Upto 5HP
171.2.8) Supply and Delivery of Submersible Pumpset with ISI mark IS 8034/2002 without Panel Board of capacity a) 30LPM x 125m (Three phase)
171.2.9) Supply and Delivery of Openwell Submersible Pumpset with ISI mark IS 14220/2002 without Panel Board of capacity b) 50LPM x 100m (Three phase)
175.1.5) Supply and fixing of triple pole and neutral four way 7 segment 3 tier compartmental type MCB distribution board
175.2.3) Supply and fixing of 4 way triple pole and neutral MCB sheet steel enclosure with bus
180.1.1) Providing and fixing 25mm x 3mm copper flat on surface or in recess for connections as required
180.1.2) Providing and fixing 25mm x 6mm copper flat on surface or in recess for connections as required for alternator neutral
180.1.4) Supply and run of 2 of No.8 copper wire for earth connections
207.3.1) Two coats of Plastic Emulsion paint including primer for inner walls.
207.3.8) Two coats of Exterior Emulsion paint including primer for outer walls
213) Supply and fixing of SFRC manhole cover a. 600mm x 600mm
b. 300mm x 300mm
238.1) Anticorrosive treatment for window grills
255.6.2) Supply and fixing of Bulk Head fitting suitable for 12W LED Bulb
255.7.2) Supply and fixing of LED bulb suitable for fixing it to pendent / backlite battern holder a) 9 watts LED
b) 12 watts LED
344.2) S&F of Bevelled edge mirror 500 x 400 x 5.5mm
359.3.2) Concrete designer tiles flooring
361.6) Vitrified Tiles flooring (Ivory)
365.1) Supplying and fixing stainless steel hand rails
367.1) Providing wooden Melamine polish for new wood work
379.4.8) S & F of Granite slab of size 4'x2' and above 18 to 20mm thick For platform (Jet black) C.M 1:3, 20mm tk
379.7.1.1) Providing PVC trim beeding of suitable size & colour for corner of wall tiles
379.8.2.3) Supplying and laying Granite tile flooring in CM 1:3, 20mm tk using (Ruby Red) for common areas
379.8.7.1) Granite Tile of size 2'0" x1'0" or 1'0" x 1'0" or 1'0" x 0'6" for wall cladding using 10mmtk (Synthetic grey) tile in C.M 1:2,
382.1) S & F of Cuddapah slab sink 600 x 600 x 200mm
383.3.1) Providing single nosing to the edges of Granite slab at entrance steps
450) Supply and fixing of 160 mm dia PVC end cap for borewell
504) Supplying and delivery of 12 mm thick nylon rope
513.1) Plate earthing with copper plate of size 600 x 600 x 3 mm as per the ISI specification with an earth electrode of 2.1 mtr class 'B' GI pipe.
529.1) Manufacturing and supply of single steel cot deluxe of size 78" x36" x18" made out of 16 CR sheet with 1" dia EWR tube head, bow, horizontal and 5/8" dia EWR tube vertical of 18 G one coat of Red oxide and tow one coat of Green Enamel paint finish
532.2) Providing one coat of Wallputty for new plastered surface
609.6.1) Supply and delivery of 150mm OD PVC casing pipes (6kg/cm2) as per IS 12818/1992 of approved quality for borewells
609.6.2) Supply and delivery of 150mm OD PVC Ribbed screen pipes (6kg/cm2) as per IS 12818/1992 of approved quality for borewells
609.6.3) Labour Charges for inserting PVC casing pipes assembly (with slots or without slots) a) 150mm dia PVC casing pipes assembly.
615.3.2) Supplying, delivery and fixing of MS fabricated DOL panel control board with ISI mark for three phase b) 5 HP
616.4.3) Supplying and fixing the following dia HDPE pipes of approved make b. 40 mm dia HDPE 10 Kg/cm2 pipe
619) Supplying and fixing of following plumbing fittings / specials confirming to I.S Specifications a) 50mm dia GM non return valve
b. 50mm dia GM Gate valve (Heavy duty)
c. 50mm dia G.I Union
d. 50mm dia G.I. Pipe
e. 50mm dia G.I. Bend
f. 50 mm dia G.I. Coupling
707.3.1) Supplying and laying 3 core 2.5 sqmm flat type copper cable with ISI mark including cost of all materials and specials.
724.5) Supply and clamping of following PVC armoured LTUG cable (Above Ground level) a) 3.5C x 120 Sqmm PVC armoured LTUG cable
b) 3.5C x 70 Sqmm PVC armoured LTUG cable
724.6) Supplying and laying of following size PVC armoured LTUG cable (Below Ground level) a) 3.5C x 120 Sqmm PVC armoured LTUG cable
b) 3.5C x 70 Sqmm PVC armoured LTUG cable
724.7) Supplying and fixing of brass cable gland suitable for a) 3.5 x 120 sqmm PVC armoured LTUG cable
b) 3.5C x 70 Sqmm PVC armoured LTUG cable
724.8) Supplying and fixing of cable end termination suitable for a) 3.5 x 120 sqmm PVC armoured LTUG cable
b) 3.5C x 70 Sqmm PVC armoured LTUG cable
741.8) Supply and fixing of 20 Amps DP plug and socket in sheet enclosure with 32 A DP MCB in Flush with wall with earth connection (For AC Plug) Legrand (MDS) / Hager (L& T) Equivalent/ Superior variety
799.1.1) Drilling of 150mm dia borewell anywhere including transportation from one place to another place in alluvial soil or sedimentary starta mud circulation method a) Drilling of borewell in upto 60m
799.1.2) Drilling of 150mm dia vertical bores in hardrock formation to any required depth using "DTH Rig" (a) Drilling of borewell upto 60m
799.2.1) Reaming from 150mm dia pilot bore to 300mm dia bore as directed by the departmental officers. a) Reaming of borewell in upto 60m
799.3.1) Charges for developing the borewell for the entire depth with air compressor of 300cfm capacity [Minimum 8 hours]
832.5.2) Supplying and fixing in position of UPVC window of casement type( open) for all sizes
832.5.3) Supplying and fixing in position of UPVC Ventilator louvered ventilator type for all sizes
943.2) Providing safety equipments: CO2 fire extinguisher : 1 No.; 9 ltrs capacity fire buckets: 3Nos., & rubber mat : 1 No.
943.5.2) Providing and fixing 6 kg capacity ABC Stored Pressure type fire extinguisher ISI marked under IS:15683 complete.
943.6) Supply and fixing of Carbon-di-Oxide Gas Type 2 kg capacity Fire Extinguisher as per New IS15683
958) Providing 13 persons passengers lift car size (2000x1100mm) Gearless Lift without Machine Room (G+4)
960.3) Supply, installation, testing and commissioning of 100 KVA Diesel Generator set complete with all accessories (with AMF panel)
960.3.1) Insulation for the residential silencer (supply of residential silencer to be included under item for DG Sets)
960.3.2) Supply and installation of M.S. cable adopter box (made of 14 SWG sheet steel) with suitable copper bus extension link from alternator.
960.3.3) Supply and installation of MS exhaust pipe of suitable thickness with 100mm dia upto 5m from the silencer complete.
960.3.4) Supply and installation of MS exhaust pipe of suitable thickness with 125 mm dia complete with MS wall / ceiling support, etc.
960.3.5) Supply and insulation of exhaust pipe thermal insulation lagging with mineral wool as per IS 3677 / 1973 reinforced with chicken mesh and cladded with aluminium sheet of 26 SWG and 50mm thick with 64 Kg/Cu. Mtr. Density.
960.3.6) Supply and installation of stainless steel rain hood / rain cap / bend at top of the exhaust pipe to prevent rain water entry to exhaust pipe with provision of drain plug in the system.
960.3.7) Preparation of necessary drawings for both DG set for approval by Chief Electrical Inspector to Government / CEA, obtain approval for the same, arrange for the inspection by the Electrical Inspectorate / CEA Officials and obtain safety certificate from them for commissioning the DG set
960.4.5.1) Supply and fixing of 4' 18 watts LED Tube Light (Crystal glass)
961) Supplying and fixing of Aluminium TNPHC Emblem of 18" height
961.1) Supplying and fixing of following height aluminium letters a) 12" height aluminium letters
b) 9" height Aluminium letters
961.2) Supply and fixing of plastic foam name plate with vinyl cutting letter with approved colours etc., complete as directed by the departmental officers a) 20"x 5"
PPSandCo
chendur construction company
SRI RAMANA BUILDING CONSTRUCTIONS PRIVATE LIMITED
Bidder Name
SRI RAMANA BUILDING CONSTRUCTIONS PRIVATE LIMITED
chendur construction company
Britto Dhanasekaran
PPSandCo
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid