| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.7 LAccepted-AOC B 30 JEEVAN VIHAR SHASTRI NAGAR GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹20.8 L+₹18,235 (0.88%)Rejected-Finance MOHALI PUNJAB 140308 | S A S NAGAR | PUNJAB | 140308 | L-2 | Rejected-Finance Not lowest | |
| 3 | L-3₹22.7 L+₹2.1 L (10.1%)Rejected-Finance | L-3 | Rejected-Finance Not lowest | |
| 4 | L-4₹25.2 L+₹4.5 L (22.0%)Rejected-Finance C 17 UPPER GROUND FLOOR C BLOCK COMMUNITY CENTRE JANAK PURI JANAK PURI JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | L-4 | Rejected-Finance Not lowest |
Tender Value
₹21.9 L
Closing Date
29 Nov 2021, 5:00 pmClosed
DIRECTOR CSIO
CSIO SECTOR 30 CHANDIGARH
Annual Maintenance Contract of staff quarters for electrical work including street lighting and non residential buildings in CSIO Colony Sector30 Chandigarh.
2021_CSIR_94168_1
CSIO/71/2021-22/ELECT
Open Tender
Electrical Works
Works
365 days
CSIO SECTOR 30 CHANDIGARH
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
27 Dec 2021
16 Nov 2021
1 Dec 2021
16 Nov 2021
29 Nov 2021
16 Nov 2021
Amount
Sub Head-I :- Man Power Note: Before Quoting the rate, contractors should ensured that Basic Per Month Rate for Item No.1.01 and 1.02 should not be less than Rs.76345.00 and Rs.45245.00 per month, respectively. This is the minimum saturatory requirement amount for compliance of the labour laws, which is based upon latest minimum wages declared by DC Chandigarh for w.e.f. 1st April'2021 + EPF@13% + ESI @3.25% + Bonus @8.33% + GST@12% + @1% labour cess but without contractor's profit. Further, Contractors are advised to quote the rate by adding suitable service charges/overhead charges amount over the above mentioned minimum amount , as per their convenience. If the per month rate quoted by the contracror found below the above mentioned rates then the tender will be rejected straight way. Note:- The payment on account of enhancement/escalation charges on account of revision in wages by DC, Chandigarh Administration from time to time shall be payable by the CSIR-CSIO to the contractor.
Deployment of Electrician - 03Nos. for day to day general repair & maintenance of the Electrical Installation, power distribution system, fitting & fixture, security lights, electrical panels, electrical operation, upkeeping of residential and non-residential buildings area in CSIR-CSIO campus area as and where required.
Deployment of semi skilled Helper/Assistant Electrician-02 Nos. for day to day general repair & maintenance of the Electrical Installation, power distribution system, fitting & fixture, security lights, electrical panels, electrical operation, upkeeping of residential and non-residential buildings area in CSIR-CSIO campus area as and where required.
Sub Head No. II: Supply of material
Single Way 5/6 Amps piano type switch
2 Way 5/6 Amps piano type switch
15/16 A piano type switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
5/6 amp moduler switch
15/16 amp moduler switch
3 pin 5/6 amp moduler socket outlet
6 pin 15/16 amp moduler socket outlet
Brass batten holder
Bell Push piano type switch
Bell/Buzzer suitable for single phase, 230 V
Capacitor 2.5mfd to 4 mfd, single phase, 250/440 volts
Two module rotory stepped type electronic fan regulator
Rubber Real for ceiling fan of single phase, 220/230 volts.
LED fitting of rating 1x20 watt, minimum length 1130mm, lumens efficiency not less than 100 Lm/watt, suitable for 230 V, 50 Hz single phase AC supply, complete as requirement . Make Anchor, Bajaj, CG, Wipro/ philips make.
Fluorescent Lamp (tube rod) 1 X 36/40 watts, 4 Feet, 230/250 volts, 50 HZ
Tube starter suitable for FTL fitting 36/40 watts, 230/250 volts, 50 HZ. ISI marked .
Electronic ballast (tube choke) 1X36/40 watts, 230/250 volts 50 Hz. Of any one of make CG/philips/bajaj/havels.
Tube fitting side holder, single-phase 230 volts, 5 amp any one of make Bajaj / Anchor /Philips / CG.
Ceiling rose, 3 pin, 5 amp ,single phase 230/250 volts
FR PVC copper wire size 1.5 Sq. mm 1.1 kV grade multi conductors ISI marked any one of make Ecko/Havells/Ralison /Anchor.
FR PVC copper wire size 2.50 Sq. mm 1.1 kV grade multi conductors ISI marked any one of make Ecko/Havells/Ralison /Anchor.
FR PVC copper wire 4.0 sq.mm 1.1 kV grade multi conductor / multicore , ISI marked any one of make Ecko / Plaza / Ralison Anchor.
FR PVC copper wire 6.0 sq.mm 1.1 kV grade multi conductor / multicore , ISI marked any one of make Ecko / Plaza / Ralison Anchor.
PVC insulated three core flexible cable of size 50/0.25mm (2.5 Sq.mm) copper conductor multi stand 1.1KV grade any one of make ECKO/ Empire/ National/ Kinjal/ Arr Kay Lite.
Twin Flat Aluminium Conductor cable of size 2 x 10 sq.mm ,1.1 KV grade any one of make: Empire/Shalimar/swadeshi as required.
PVC conduit pipe medium class 2mm thick, ISI marked of size dia. 25mm anyone of make Diplast/ Prince/ Finolex.
Minor material like iron staples/ saddles/ screws for fixing the bakelite sheet with MS boxes, PVC pipe, flexible pipe etc. as required.
Phonallic laminated sheet of 3 mm thick, ISI marked anyone of make Hylem/ Super/ Heylem.
PVC batten of size 25 mm X 10 mm (casing & capping) ISI marked.
PVC gang box suitable for 2 switches and 2 sockets of 5amp. Complete in all respect as required at site.
PVC gang box suitable for 1 switch and 1 socket of 15amp. Complete in all respect as required at site.
Miniature circuit breaker, 5 A to 32 A rating of Single pole, 240/415 V, 10 kA, “C” curve, suitable for inductive load as required.
Miniature circuit breaker, 5 A to 32 A rating of Double pole, 240/415 V, 10 kA, “C” curve, suitable for inductive load as required.
Miniature circuit breaker, 5 A to 32 A rating of Triple Pole & Neutral , 240/415 V, 10 kA, “C” curve, suitable for inductive load as required.
Residual current circuit breaker (RCCB) 40A, double pole, (single phase and neutral), 240 V, having a sensitivity of current 30 mA as required.
Residual current circuit breaker (RCCB), 63 Amp., four pole, (three phase and neutral), 415 V, having a sensitivity current 30 mA as required.
SPN industrial type, socket outlet, 20 amps, 240 volts, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' series, SP, MCB, in sheet steel enclosure as required.
Timer switch Series FM/1 Quartz Type QT(Daily)Single phase 230/ 240 volts 50/60 Hz GIC/ L&T make suitable for street light controls.
Contactor of rating 40-50 Amp , three phase 415 Volts, 50 Hz with coil operating voltage 220/400/ 440 V operation complete as required.
LED street light fitting of rating 36/40 Watt , single phase, 230V, 50Hz complete in all respect.
LED type street light fitting of rating 72/80 Watt, single phase 230V, 50Hz complete in all respect.
LED type street light fitting driver/ controller of 36/40 watts and LED plate 36 watt complete in all respect as required at site.
LED type street light fitting driver/ controller of 72/80 watts and LED plate 72 watt complete in all respect as required at site.
Thermoplastic Cable Junction Box IP 65 of size 200mm X 160mm X 98mm deep (nominal size), suitable for connecting of aluminium cables of size 16/25 sq.mm complete with terminals set of 4 Pole, metric knockouts for cable entry etc.,
Globe/dome diffuser of size 12" suitable for pole mounted street light pole as rquired.
MCB distribution board, 8 way, double door, single pole and neutral, sheet steel, 240 volts as required at site.
Self adhesive PVC Insulation Tape Role of size 1.80cm x 6.5m x 0.125mm, ISI marked.
Self adhesive Punture Tape Role for power cable repair.
Ball bearing of number size from 6200 - 6203 nos.
DWC HDPE Pipe of size 90mm dia, ISI marked.
Post Top Lantern out door light fitting suitable for fixing retrofit LED lamp, 220-240 Volts, 50Hz, suitable for 40 to 60mm O.D. mounting pipes, complete with LED retrofit lamp of 9W, of good quality as approved by the Engineer-In-charge.
SUB HEAD-III: PETTY JOBS
Charges for rewinding of ceiling fan size 1200/1400 mm sweep of USHA/ Kessle/ Khaitan/ CG make of different models complete in all respect up to working condition of CF.
Charges for repair, and overhauling of single phase ½ HP rating mono block pump set complete in all including all material like bush/ capacitor/ bearing of etc. upto running condition of motor at site.
Charges for rewinding of single phase ½ HP rating mono block pump set including repair of pump, shaft, seal bearing etc. and complete in all respect upto running condition of motor as required.
Alluminium Painting of street light pole from size 3 M to 9 M GI/Tuber type pole including white wash of cement concrete muff and red/gray paint to connection box of street light pole complete in all respect as required at site.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and Laying of 6 SWG GI wire at 0.50 meter below ground level for conductor earth electrode, including soldering etc. as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade upto 35 sq. mm. direct in ground including excavation, sand cushioning, protective convering and refilling the trench etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required. (i) Group A (Upto Type-III Residential Quarters)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required. (ii) Group B (Type-IV and above Residential Qtrs.)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 2X2.5 sq mm + 1X2.5 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item including PVC condute pipe + PVC wire)
Wiring for circuit/ submain wiring alongwith earth wire with the 2X4 sq mm + 1X4 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item including PVC condute pipe + PVC wire)
Wiring for circuit/ submain wiring alongwith earth wire with the 2X6 sq mm + 1X6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item including PVC condute pipe + PVC wire)
Providing and laying cement concrete 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) in muffs of Dia 15 inche and height 2 feet approx. for street light poles , including of Centering and shuttering including strutting, propping etc. and removal of form and 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) complete as directed by Engineer in charge. It also includes breaking of existing RCC muff and shifting of material from site as required.
Supply, installation, testing & commissioning of cubical type,outdoor type, single door, Floor mounted, fixed type, free standing single front, dust proof Outdoor Aluminium Bus Bar Feeder Pillar made out of M.S. CRC Sheet 14SWG, Base Frame Angle 40X40X5mm duly red Oxide Primer with PO Red Paint as per specification. Approximate Size (H) 1200mm X (W) 900mm X (D) 300 mm to 450mm X (L) 600 mm long legs. Bus Bar size 400A TPN Aluminium Busbar (Horizontal) & Earth strip throughout the length of Panel Busbar supports shall be DMC epoxy Insulators. Aluminium Bus Bar shall have 12mm dia. holes and all Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. Aluminium solid interconnection Busbar to to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables & without Power Wiring. Rewireable fuse units should have provision of minimum four numbers outgoing cables of size 16 sq.mm to 150 sq.mm. Panel should be complete with all accessories like Gasket, Doorlocks, earthing stud etc. and should be as per Technical specification of CPRI guidelines. Panel should be fabricated from the approved panel fabricator.
FAIR DEAL ENGINEERS
Manohar Electricals
S. N. ELECTRIC & MAINTENANCE PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .