Tender Value
₹7.5 L
EMD Value
₹15,100
Closing Date
28 Apr 2025, 6:00 pmClosed
CWE Bengdubi
Headquarters Commander Works Engineer Bengdubi Post-Bengdubi Distt-Darjeeling (WB) PIN- 734424
REPAIR MAINTENANCE OF VCBs, TRANSFORMER, RMU AND ALLIED WORKS AT MAUZA DALAN AND SIRSA CAMP AREA AT KATIHAR MIL STATION UNDER AGE(I) KATIHAR
2025_MES_698908_2
8275/KTR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Katihar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) Katihar
₹15,100
13 Jun 2025
5 Apr 2025
1 May 2025
5 Apr 2025
28 Apr 2025
15 Apr 2025
Amount
M&L for carrying out the repairs to transformer,step down,11/0.433 kV , 315 to 400KVA at existing position on platform after disconnection of HT/LT connections & earthing lead , opening of transformer cover plate, taking down of transformer oil to a level as required and kept in clean and dry container for re use at same time , repairing/overhauling to the defective parts/components including replacement of unserviceable parts as directed, making connection of the transformer after repair , topping of the tankwith the same transformer oil,dehydrated old oil with new oil as required/directed and testing the transformer all as specified and directed. Note: The quoted rate shall be deemed to include for all repairs/replacements, other elements etc to make the transformer fully functional and serviceable to the entire satisfaction of Engr in charge. However the payment for the items as included required ordered and executed shall be paid seperately.
Vaccume dihydration with hot filteration plant of old transformer oil at different locations, after filteration, Di electric strength shall not be less than 55 KV in 2.5 mm gap electrode, complete all as specified and as directed. The contractor shall submit necessary Test Report for Di electric strength before dehyderation as well as after dehyderation from CPRI /Govt approved Lab as per relevant IS. The contractor's quoted rates shall also be deemed to include for this element. Note:- (i) Transformer Oil after dehyderation shall be measured and considered for the payment under the item. (ii) The contractor must have own one dehydrated hot Vacuum Filtration plant of miniumum filtration capacity 1000 ltr/hr. Tranformer oil Filtration plant with a provision of oil test set for immediate showing result. The plnt must have provision of on load filtration.
Supply only transformer Oil conforming to IS-335 of 1993 (make : POWER OIL/HP/BP) for toping up /oil change of Transformers of any capacity at different locations, complete all as specified and as directed. Notes:- (i) The dielectric strenght of the transfomer oil shall not be less than 55 KV in 2.5mm gap electrode. (ii) Quoated rate shall also be deemed to include for testing of transformer oil from CPRI / Govt. approved lab as per relevant IS and submission of necessary test reports.
Supply only 6mm thick synthetic bonded cork gasket sheet for top cover and primary/secondary bushes for the capacities of transformers 11/0.415 kV of capacity 315 KVA. Make of Transformer - Volt Amp, complete all as specified and directed.
Supply only 6mm thick synthetic bonded cork gasket sheet for top cover and primary/secondary bushes for the capacities of transformers 11/0.415 kV of capacity 400 KVA. Make of Transformer - Volt Amp, complete all as specified and directed.
Supply only silica gel breather for transformers of 315 and 400 KVA capacities of superior quality 5 to 10 mm grade, blue in color,complete all as specified and as directed.
Supply only breather assembly having transparent MS body with top and bottom portion pressed with metallic cover for transformers of capacities 315/400 KVA, suitable for fixing on existing pipe as per site requirement complete all as specified and as directed.
Supply only porcelain bushing on HT side, copper stud assembly as per the existing duly threaded at both ends with and including oil seal, heavy gauge brass nuts, washers suitable for the 11/0.433kv step down capacity of transformers 315/400 KVA, complete all as specified and as directed. Make: Pactil/Jaipuria/ABI
Supply only porcelain bushing on LT side, copper stud assembly as per the existing duly threaded at both ends with and including oil seal, heavy gauge brass nuts, washers suitable for the 11/0.433kv step down capacity of transformers 315/400 KVA, complete all as specified and as directed. Make: Pactil/Jaipuria/ABI
Supply only Oil temperature indicator with two mounting switch,3 meter capillary length, ranging from 0 to 150 degree C,alarm and trip mechanism suitable for existing 11/0.433 kV step down transformer of capacity 315 KVA and 400 KVA complete all as specified and as directed.
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity up to 400 KVA 11/.433 KV outdoor / Indoor type with one coat of spray painting with synthetic enamelled gray paint (first grade) by spray painting machine on transformer & Marking of SM/MES No on surface of transformer complete all as specified.
M & L for cleaning , scraping out old rubbed paint / rust & Painting of transformer complete of capacity up to 315 KVA 11/.433 KV outdoor / Indoor type with one coat of spray painting with synthetic enamelled gray paint (first grade) by spray painting machine on transformer & Marking of SM/MES No on surface of transformer complete all as specified.
M & L in replacement Pin type, porcelain, vitreous, white , brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed. Make:BHEL/Jaypuria Brothers/Pactil/ Southern Insulators
M&L in replacement Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 11 KV complete all as specified and as directed. Make:BHEL / CG /BHARAT BIJLEE /OBLUM / PRAGATI .
Supply, jointing and testing in repairs, cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrink type joint, complete with and including jointing materials and accessories suitable for 11KV XLPE insulated armoured aluminium conductor cable of size 50 to 95 Sqmm 3 core, complete all as specified and as directed by the Engineer-in-Charge. Make: M-Seal/3 M/Dension/Raychem
Supply, jointing and testing in repairs, cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink type joint, complete with and including jointing materials and accessories suitable for 11KV XLPE insulated armoured aluminium conductor cable of size 50 to 95 Sqmm 3 core, complete all as specified and as directed by the Engineer-in-Charge. Make: M-Seal/3 M/Dension/Raychem
Supply, jointing and testing in repairs straight through cable jointing kit (Heat shrinkable type) for 11 KV (Earthed) grade cable complete with and including jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm and also including provision of aluminium thimbles, complete all as specified and as directed by the Engineer-in-Charge. Make: M-Seal/3 M/Dension/Raychem
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade (Earthed) of size 95 sqmm 3 core and including taking down, complete all as specified and directed. Make:Polycab/ Havells India Ltd./Gloster Cables Ltd/KEI Industries Ltd./Gupta Power/ Finolex/RR Kabel/ MESCAB/Richa Cable Note:- Excavatioin and earth work, sand cushioning, protection covers, protection pipes and jointing kits Iincluding jointing materials shall be measured and paid for separately.
Supplying and laying in repair synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed.
Supplying and laying in repair synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 metre wide and not exceeding 1.5m in depth for laying of LT under ground cables/ pipes/stay assembly and not exceeding 10 Sqm on plan & 1.5 metre in depth for pole etc, complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm thick in layers, complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed.
M& L for Sand cushioning in trenches for cushioning of underground cable including spreading, levelling, well ramming in layers not exceeding 25cm in thickness, complete all as specified and directed.
Supplying and laying factory made (Make as approved by the GE) pre cast unreinforced concrete cable cover class HV, type 1, flat, size 300mm x 180 mm x 40 mm for cable protection in trenches, complete all as specified and directed.
S&F in repairs Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with and including M.S.clamps, bolts and nuts of approved size for 11 KV HT, 25x20cm size, complete all as specified and directed.
Surface excavation in hard/dense soil including sand and pebbles n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in power houses/ sub station complete all as specified and directed.
M&L in replacement Switch Air Break, Gang operated, Triple Pole, Mechanically Operated, mounted on insulators and Steel Frame Single Break Insulators suitable ofor Out door Vertical Mounted complete with Manual Operating Mechanism made and operation from GL including 25mm bore GI pipe heavy duty and handle Arching Horns and Terminal Connectors for ACSR Conductors conforming to IS-1818/72 and 9921/85 with 3 Isolator Per Pole of Capacity 400 Amp, 11 KV Operation including necessary Adjustment and making Holes on Mild Steel Angle and Testing complete all as specified and as directed by the Engineer-in-Charge. Make:Pactil/ BHEL/Jaypuria Brothers
M&L for repairing of GOD i.e. replacement of spares like male, female contact, moving contact, flexible jumper, bolts, nuts, including necessary cleaning & applying grease to make the GOD fully functional to the entire satisfaction of the GE, complete all as specified and directed.
M&L earthing complete with copper earth plate electrode of size 600 x 600 x3.15 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to copper earth strip of size 20x3 mm by means of bolts, nuts, check nuts and washers of copper, complete including testing all as shown in Electrical Plate No. 3 of SSR Part-1 and connected to earthing test point and including dismantling of old one, complete all as specified and directed. Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead rotection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead of GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, complete all as shown in Electrical Plate No. 3 of SSR Part-1 and connected to earthing test point and including dismantling of old one, complete including testing all as specified and directed. Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead rotection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S&F in replacement for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20x3 copper strip using porcelain clit/post insulator including brazing if required complete all as specified and directed.
S&F in replacement for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6 GI strip using porcelain clit/post insulator including brazing if required complete all as specified and directed.
Supply and fixing GI tubing, light grade, 40mm bore for protection of cable/GI strip, under road crossing, across drain, along electric pole or floor /wall etc, complete including taking out existing pipe, complete all as specified and as directed by the Engineer-in-Charge. Make:Surya Roshni Ltd./Tata / Jindal Steel /Prakash Note: Excavation & Earth work shall be measured & paid for separately.
M/s.Alam Enterprises (BID ID -3285367)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .