Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 8 803 AGARWAL B2B CENTRE KANCHPADA ROAD MALAD WEST MUMBAI MUMBAI MAHARASHTRA 400064 | MUMBAI SUBURBAN | MAHARASHTRA | 400064 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
30 Sept 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASHISH PATHAK
RCFL, CHEMBUR, 400074
NOTICE INVITING TENDER FOR SUPPLY OF SPARES OF RCF SUPPLY PUMP IN STP-2 ON PROPRIETARY BASIS
2021_RCFL_649590_1
E224210964
Limited
Miscellaneous Goods
Supply
90 days
RCFL CHEMBUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
30 Sept 2021
23 Sept 2021
30 Sept 2021
23 Sept 2021
30 Sept 2021
23 Sept 2021
120 days
UPPER HALF CASING (ALONG WITH PLUGS AND VENT VALVE) FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 12200 2) MATERIAL: CI IS210:FG260 NI 2.5 MIN 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
LOWER HALF CASING (ALONG WITH LOCATING PIN) FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 12300 2) MATERIAL: CI IS210:FG260 NI 2.5 MIN 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
WEARING RING (ALONG WITH LOCKING PIN) FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 19000 2) MATERIAL: CF8 M 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
SHOULDER RING FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 19900 2) MATERIAL: CI IS210:FG260 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
BEARING HOUSING DE (ALONG WITH GREASE NIPPLE) FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 24001 2) MATERIAL: CI IS210:FG260 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
BEARING HOUSING NDE (ALONG WITH GREASE NIPPLE AND PLUG) FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 24002 2) MATERIAL: CI IS210:FG260 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
INSERT FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 97900 2) MATERIAL: CI IS210:FG260 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
SPLIT GLAND FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 22300 2) MATERIAL: CI IS210:FG260 NI 2.5 MIN 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
O'RING SET FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 52201 2) MATERIAL: NEOPRENE RUBBER 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE
LANTERN RING FOR RCF SUPPLY PUMP IN SEWAGE TREATMENT PLANT NO.2 AS PER THE FOLLOWING SPECIFICATIONS: SPECIFICATIONS: 1) PART NO.: 22700 2) MATERIAL: NYLON 3) PUMP MODEL: UP250/38. 4) CAPACITY: 688 M3/HR. 5) HEAD: 40 MTR. 6) POWER: 110 KW. 7) SPEED: 1486 RPM. 8) OA NO. : A01318A524/300 9) PUMP NO.: 1746418082 10) PUMP MAKE: M/S KIRLOSKAR BROTHERS LIMITED NOTE: VENDOR TO ENSURE THAT ITEM SUPPLIED IS INTERCHANGEABLE TO THE EXISTING INSTALLED ONE.
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .