Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 Accepted | |
| 2 | L2₹28.2 L+₹3.6 L (14.4%)Accepted-AOC | L2 | Accepted-AOC Being L1 rejected | |
| 3 | L3₹28.6 L+₹4.0 L (16.3%)Rejected-Finance H NO 920 SEC 16 17 HISAR HARYANA 125005 | HISAR | HISAR | HARYANA | 125005 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹35.7 L+₹11.1 L (45.0%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
23 Aug 2021, 6:00 pmClosed
GE WEST HISAR
GE WEST HISAR HISAR MIL STN HISAR 125006
SPECIAL REPAIR TO TO BLDG NO P-538 (OFFICER SINGLE ACCN) OF 33 ARMD DIV SIG REGT AT HISAR MIL STN UNDER GE (WEST) HISAR
2021_MES_461275_1
GE(W)HSR-14/2021-22
Open Tender
Civil Works
Item Rate
180 days
HISAR MILITARY STATION
please refer tender documents
9 documents required · 9 mandatory
₹500
Yes
GE WEST HISAR
₹77,000
Yes
25 Sept 2021
19 Jul 2021
25 Aug 2021
19 Jul 2021
23 Aug 2021
9 Aug 2021
Amount
Taking down cement plaster incl racking out joints, hacking for key & scrubbing down with water etc including removing rubbish complete all as specified and directed.
Demolition cast in situ terrazo/ terrazo tiles of any thickness of walls or floor incl cement screed at any floor etc including removing rubbish complete all as specified and directed.
Demolition of cement concrete of ant description and in any position not otherwise specifically provide for incluiding removing rubbish complete all as specified and directed.
Demolition of reinforded cement concrete of any description and in any position not otherwise specifically provided for chajjas, roof projection, PCC railing, Columns taken for pressure grouting including removing rubbish complete all as specified and directed.
Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) incluiding removing rubbish complete all as specified and directed.
M&L for 15mm thick plaster in CM 1:4 on brick or concrete wall surface finished even and fair without using extra cement mixed with liquid water proofing admixture as per manufacturer's instructions complete all as specified and directed. Note :- WPC will be paid separately.
M&L for 10mm thick rendering in CM 1:6 over brick / concrete wall surfaces trowelled to even & fair w/o using extra cement for internal wall surfaces complete all as specified and directed.
M&L for 10mm thick rendering in CM 1:3 over brick / concrete ceiling surfaces trowelled to even & fair w/o using extra cement for internal wall surfaces complete all as specified and directed.
M&L for rough cast plaster as specified (rendering coat not less than 10mm thick in CM 1:3, while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate size 6 to 12mm mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even) on external wall upto cill height complete all as specified and directed.
M&L for Matt fiish vitrified ceramic tiles 10mm thick (square /rectangular ) polished , area of each tiles not exceeding 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed flush in white or colour cement with pigment over and including 15mm thick cement mortar 1:6 screed bed complete all as specified and directed.
M&L for Vitrified ceramic tiles 10mm thick (sqare /rectangular ) polished , area of each tiles not exceeding 0.42 Sqm, in Vertical surfaces, dados/skirting etc set and jointed in neat cement slurry and pointed flush in white or colour cement with pigment match the surface over and including 10mm thick baking coat of CM 1:4 in double charge complete all as specified and directed.
M&L for coloured designer glazed ceramic tiles of size 300x450x7mm/ 250x350x7mm/600x300x7mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:3 complete all as specified and directed.
M&L for 20 to 25mm thick machine cut Kota stone (550 x 550 mm) flooring over cement screed base laid and jointed with grey cement slurrry mixed with pigments to match the shade of the slab including rubbing and polishing complete all as specified over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. Note : For stair case and window cill, kota stone shall be provided in single piece upto 1.50m length.
All as per item No 13.00 but kota stone slab (100/150mm x 550mm) and 20-25mm thick in riser of steps, skirting , dados and pillar laid over and including 10mm thick rendering to receive the stone in cement mortar 1:3 and jointed complete all as specified and directed. Note : For stair case and window cill, kota stone shall be provided in single piece upto 1.50m length.
M&L for 20mm thick granite stone slabs over and including 15 mm thick screed layer in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of stone incl rubbing & polishing complete all as specified and directed.
Rounding to edges of stone slabs (Kota / Granite) one edges such as in steps, cooking platform and other similar situations all as specified
Taking up or down steel water tubing and connections including for re-fixing or removal to store 15 mm bore of pipe complete all as specified and directed.
M&L for steel water tubing (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 15 mm bore of pipe complete all as specified and directed.
S&F 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. and directed.
S&F brass threaded Tee suitable 20mm outer dia CPVC pipes complete all as specified. and directed.
S&F brass threaded elbow suitable 20mm outer dia CPVC pipes complete all as specified. and directed.
S&F brass threaded Male / female Adaptor (MTA/ MBTA) ) suitable 20mm outer dia CPVC pipes complete all as specified. and directed.
Taking up or down steel water tubing and connections including for re-fixing or removal to store 20 mm bore of pipe complete all as specified and directed.
M&L for steel water tubing (medium grade) galvanised with all fittings and fixed complete to walls and ceiling or laid in floors 20mm bore of pipe complete all as specified and directed.
S&F in repair chromium plated stop cock, cast copper alloy with long shank and cup (concealed) high pressure, screwed both ends for 15mm bore iron pipe or bras ferrule complete all as specified and directed.
S&F in repairs 15mm bore bib tap, brass chromium plated cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified. Make : Parryware Cat No 2304 A-1 or equivalent as approved.
S&F in repairs 15mm bore angle valve, CP cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed. Make : Parryware Cat No 2307 A-1 or equivalent as approved.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair brass chromium plated towel rail 600mm long fixed with and including screws and wooden / plastic cleats (minimum weight 190 gms) complete all as specified and directed.
S&F in repair brass chromium plated shower rose 200mm size with or without swivel joints including Stainless steel arm fixed to steel pipe or union complete all as specified and directed.
Dismantling old u/s PVC water tanks exc 500 & n exc 1000 ltrs capacity complete all as specified and directed..
S&F 1000 ltr capacity rotional molded polythylene water storage tank three layer white triple layer (Cylinderical vertical with closed top , white in colour ) hoisted kand fixed in position including ball valve 20mm bore high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed, (minimum weight 210 gms)complete all as specified and directed.
S&F in repairs vitreous china one peice wash down water closet pan (padestal pattern ) Make -Parryware including P / S trap and soft close seat cover with hinging device and CP jet spray with hanging device all necessary work required for fixed in position complete all as specified and directed. Make: Parryware cat No C0258 or equivalent as approved.
S&F in repair cardiff health faucet with hose and hook complete all as specified and directed.
S&F in repair brass chromium plated Basin Mixer single lever for counter top WHB complete all as specified and directed.
S&F in repair CP Brass wall mixture for mixing hot and cold water screwed down for iron pipe and fixed in posn complete all as specified and directed.
S&F in repair soap Dish complete all as specified and directed.
S&F in repair glass shelf 60cm complete all as specified and directed.
S&F in repair 600x450x150mm fibre body cabinate looking mirror with 5.5mm thick glass complete all as specified and directed.
M&L for cement concrete 1:5:10 type E-2 (40 mm graded aggregates ) as in filling and mass concrete in suken portion complete all as specified and directed.
M&L for treatment of sunken floor slab comprising of the following specifications complete all as specified and directed :- (i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thermax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out. (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty Sikagard 694 F (I) or equivalent make in Fosroc /Thermax as approve by GE. (iv) After drying putty, wash the slab and sides of sunken portion with water andmake it clear and clean. (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or equivalent make in Fosroc / Thermax as approved by GE in two coats @ 3kg/sqm to sandwiched with glass fibre reinforcement : Sika® Fab-1 or equivalent make in Forsro / Thermax as approved by GE over base coat as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound SIKA plastocreat Plus or equivalent make in Fosroc / Thermax as approve by GE @ 0.2% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint
Supply only intergal liquid water proofing compound complete all as specified and directed.
S&F in repair vitreous china counter top wash hand basin (Size 560x455x200mm) colour brilliant / off white incl waste pipe and waste coupling over and including prepolished granite top RCC platform of size 1000 x 600mm size complete all as specified and directed. Make : Parryware cat part No Leed N C0483 or equivalent of CERA, Hinduware as approved.
S&F in repair 75mm outer dia PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
Taking down chowkats or frame without taking off shutters (with or without glazing and ventilator) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frame with shutter, without taking off shutter from the frames area exc 1.5 sqm but not exc 4sqm each complete all as specified and directed.
S&F pressed steel frames 125x60mm for doors with one or more rebates made out of 1.25mm thick PBI sheet including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
S&F pressed steel frames 105x60mm for doors with one or more rebates made out of 1.25mm thick PBI sheet including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reiforced with MS square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles with particle board core), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, upplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F 30mm flush door shutters, soild core construction, with block board core and both face covered with decorative face veneer with lipping / frame to match, complete all as specified and directed.
S&F 35mm thick glazed and skelton shutters open rebated and prepared to receive gauze etc (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred breds for securing glass etc sizes of members of shutters as specified in SSR Pt-I Sec 8 Clause 8.20(a) in 2nd class hard wood complete all as specified and directed.
S&F Pressed steel factory made cupboard shutter with frame of 1.25mm thick and shutter 1mm thick PBI sheet with 6 Nos 3.15mm thick and 100mm long steel hinges Godrej pattern locking arrangement including 12mm dia vertical rod. Shutters shall be spray painted in factory (total width including frame shall be measured and paid) including taking down
S&F aluminium anodised powder coated windows, ventilators, doors, partition,sliding door and windows, grill including facbrication of frame / shutters and fixing with and including necessary lugs, hinges, cleats, rollers, aluminium handles, locking arrangement, glazings clips, and rubber beadings for fixing glass panes and wire mesh in frame complete all as specified and directed. Note : (i) Glass panes and wire cloth shall be measured & paid separately . (ii) Necessary fittings like lugs, hinges, cleats, rollers, handles, locking arrangement, glazings clips, and rubber beadings shall deemed to be included in quoted rate and shall not be measured and paid seperately.
S&F stainless steel Gde 304 in railing of stair case and other locations of approved design/ pattern including studs/fastners etc for fixing of railing and welding / polishing complete all as specified and directed..
M&L for PCC 1:3:6 type C-0 (using 12.5mm Graded Stone Aggregate) as in filling of Chowkhats complete all as specified and directed..
S&F Sheet glass tinted in aluminium door and widows 5 mm thickness complete all as specified and directed..
S&F Aluminium anodised barrel tower bolts of extruded section and fixed 200 mm complete all as specified and directed..
S&F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clip of sheet,cast or extruded section, bolt not less than 16 mm dia, 250 mm long complete all as specified and directed.
S&F 100mm stainless steel butt hinges complete all as specified and directed.
S&F aluminium handles extruded fabricated type anodized of size 150mm complete all as specified and directed.
S&F 25mm dia stainless steel curtain rod with 02 Nos fancy SS finial and SS brackets for each opening complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for 17-18 mm thick MDF Board both side white laminating using in cabinates, almirah partition, Drawers, shutters etc as per standard trade practise exterior grade complete all as specified and directed.
Dismantling Boarding any description fixed in any position with nails and remove from site complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coat of plastic emulsion paint of any tint including priming plastered surfaces with alkali resistant priming paint over one coat of wall care putty minium 1.5mm thick complete all as specified and directed.
M&L for preparation of old painted wall surfaces incl complete removal of existing treatment and applying two coat of plastic emulsion paint of any tint over one coat of wall care putty minium 1.5mm thick complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation old plastered ceiling surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
M&L for preparation new wood or wooden based material surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint of any tint over a coat of pink primer complete all as specified and directed.
M&L for preparation new steel or iron surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint of any tint over a coat of red oxide complete all as specified and directed.
M&L for preparation old steel or iron surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint of any tint complete all as specified and directed.
M&L for preparation old plastered surfaces and applying two coats of exterior weather proof paint over one coat of primer over one coat of exterior putty on wall after complete removal of existing treatment complete all as specified and directed.
M&L for preparation new plastered surfaces and applying two coats of exterior weather proof paint over one coat of primer over one coat of exterior putty on wall complete all as specified and directed.
M&L for 50mm thick, cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in plinth protection, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed. .
M&L for repairing to RCC chajja of doors/ windows area not exceeding 1.0 Sqm with PCC1:2:4 type B1 using 20mm graded crushed stone aggregate or cement mortar1:3 as complete all as specified and directed. by Enge in charge
M&L for providing precast cement concrete type B-I 1:2:4 using 20mm graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face set in cement mortar 1:4 complete all as specified and directed.
S&F in reapair PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors dia of pipe 110mm complete all as specified and directed.
S & F in repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors dia of pipe 75 mm complete all as specified and directed.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls dia of pipe 110mm complete all as specified and directed.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wallsdia of pipe 75mm complete all as specified and directed.
S&F in repair PVC Bends 110mm bore, with/ without oval access doors complete all as specified and directed.
S&F in repair PVC Bends 75 mm bore, with/without oval access doors complete all as specified and directed.
S&F in repair PVC branch piece 110mm bore, with oval access doors complete all as specified and directed.
S&F in repair PVC branch piece 75 mm bore, with oval access doors complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl suitable for 110mm dia pipe
M&L for brickwork with old size, fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition Mud in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Demolitin of Brick tiles or terracing tiles, single layer on roofs and removing from site complete all as specified and directed.
M&L for cement concrete 1:2:4 mix type B-1 (using 12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and fair (without using extra cement) in slope 1:40 over roof complete all as specified and directed.
M&L for Screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 with WPC on roof surfaces complete all as specified and directed.
M&L applied a coat of bituminious primer confirming to [email protected] Kg per Sqm ,APP BASED POLYMERIC Memberane not less than 3 mm thick. Weighing not less than 3 Kg/m2, reinforcd with polyster non woven febric(weighing not less than 15 Gm/Sqm) and upperside of memberane thermally insulated with white mineral gravel finish, uniformly embedded during manufacturing process shall be laid dry torch application, side coverlaps shall be 75 mm and end slab shall be 100 mm and all over laps and joints shall also be sealed by torch application including one coat of bituminous aluminium paint all as specified and directed.
S&F in repair 15mm dia pipe gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20mm dia pipe gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair Door closer aluminium diecast body hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg as approved complete all as specified and directed.
S&F floor door stopper of aluminium alloy body size 75 mm with two rubber shoes complete all as specified and directed.
S&F in repair salt glazed stone ware gully traps in repairs square or rounded mouthed type P or S of size 150 x 150cm incl excavation earth work conc in Beds, surrounds kerbs etc complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed stoneware, AC or reinforced concrete pipes) 200mm internal dia set in cement mortar complete all as specified and directed.
S&F salt glazed stoneware drain pipes as per IS-651 200mm dia laid in trenches and jointed in cement complete all as specified and directed.
M&L for concrete bed in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) to drain pipes of 200 mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for form work to rough finished flat surfaces of RCC members etc complete including edges complete all as specified and directed.
M&L for mild steel TMT bar 10mm dia or over cut to length bent to shape reqd incl cranking bending etc complete & binding with MS wire (annealed) not less than 0.9mm dia used as extra supportive reinforcement at columns taken under gunniting / shortcreting complete all as specified and directed.
All as per item No 104 above but 8mm dia complete for stirrups etc complete
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, door chowkats of angle or other section and similar works complete of Gde Fe-290 Gde E-165 including welding etc complete all as specified and directed.
M&L for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture SIKA Plasto creat plus or equivalent make in Fosroc / Thermax as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. the gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions complete all as specified and directed.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg/ltr at 30°C and consumption : 0.2 kg/Sqm/coat complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar
Supply and apply cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and product requirements: carbonation resistance : 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N/Sqmm according to ASTM C 882-78 complete all as specified and directed. Note : The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructionscomplete all as specified and directed.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out in soft/loose soil complete all as specified and directed.
M/L for 75mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in subbase complete all as specified and directed.
M&L for rubber moulded vibratory cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and no pigment.over and incl 25mm thick sand layer complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed.
Removing excavated material exc. 250m but n exc. 500 m and depositing where directed complete all as specified and directed.
M&L for Brickwork with old size, flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed.
S&F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore pipe complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for Point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in and including pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor to common earth and connecing to earth dolly for one light/ ceiling fan /bell point controlled by one one switch including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No. 120 above but for one 5 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per item No. 120 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
All as per srl item No. 120 above but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
Taking down carefully copper/aluminium Submain wiring from battan /conduit from DBs,MCBs, etc) and making good to disturbed surfaces of walls, floor etc. all as specified and directed
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including PVC casing and caping with acessories and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC casing and caping will be measured as one length).
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including PVC casing and caping with acessories and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC casing and caping will be measured as one length).
S&F switch bell push modular flush type, single pole, one way, 5 Amp, 230/240 Volts complete all as specified and directed.
S&F bell ding dong type, single pole, one way, 5 Amp, 230/240 Volts complete all as specified and directed.
S&F modular switch single pole, one way, 6 Amp, 230/240 Volts grade complete all as specified and directed.
S&F modular socket outlet multipurpose 3&6 Pin, 16 Amp 230 volts AC complete all as specified and directed.
S&F nodular socket outlet multipurpose 2&3 Pin, 5/6 Amp 230 volts AC complete all as specified and directed.
S&F modular switch single pole, one way, 16 Amp, 230/240 Volts grade complete all as specified and directed.
S&F Lamp holder of PVC / Polycarbonate type surface with 9 watt LED bulb complete all as specified and directed.
S&F modular fan reglator step type 2 module 230 volt complete all as specified and directed.
S&F modular ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
S&F LED tube light fitting 18W metallic frame /batten, Retro, Box type surface and wall mounted, including LED tube light rod , high efficiency including making connection, complete all as specified and directed.
S&F MCB SPN, 32 to 40 Amps 240 Volts , type 'B' curve, 10 KA, for fixing in DB complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
S&F Sheet metal enclosures for DBs when MCBs to be used Single pole and neutral, 240 Volts with 200 Amps rated busbar 8 way double door complete all as specified and directed.
S&F Sheet metal enclosures for MCCB DBs when MCCB, MCBs used VTPN 415 Volts with 200 Amps rated busbar 4way double door complete and all as specified and directed
S&F MCCB 63 Amps 3 pole , breaking capacity 16 KA complete all as specified and directed.
S&F Ceiling fans regulator, single phase 230 volt, 1200mm sweep energy efficient rating complete all connecting accessories etc and duly writing MES No complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
Supplying laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core including taking down old U/S cable complete all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Eexcavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out and getting out in soft/ loose complete all as specified.
Returning filling with earth obtained from excavation including spreading, consolidation in layers not exceeding 15 cms thick, complete all as specified and directed.
Removing earth obtained from excavation including spreading, consolidation in layers not exceeding 15 cms thick, complete all as specified and directed.
M&L for Sand filling in trenches with clean dry fine sand unwashed 8cm thick below cable and 15 Cm thick after laid thincluding gently punning around cables complete all as specified and directed Note : 18cm punned thickness shall be measured and paid
M&L for bricks covering to under ground cable using sub class B bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed.
S&F in replacement LED street light luminaries of cap 30 watt, SPD 10 KV internal with lense, 240 volt, pressure dia cast aluminium housing frame, heat resistant toughtened clear glass with frame complete with accessories , IP 66 protection, pre wired up to a terminal block and mounting/attachment of GI pipe 40mm dia light grade bend to required shape for fixing of light of length 1.2 mtr including MS clamps nuts bolts & washer duly required with PCC in wall complete all as specified and directed.
M&L for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall/pole for protection of cable/earthing strip etc complete all as specified and directed.
S&F in replacement LED light fitting complete 1 x 9W, (2Ft long) polycarbonate batten incluing LED tube complete all as specificed and directed.
S&F in replacement LED light fitting surface mounting round type complete 1 x 12W, (Dimension(mm) for round light : 0180x40) polycarbonate batten incluing LED tube complete all as specificed and directed.
S&F in repair sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one single pole MCB of 20 Amp 10KA type 'B' series 240 volts complete all as specified and directed.
Taking down and cutting down & removing old copper winding wire and rewinding the same with new super enameled re fixing ceaning, greasing, oiling and servicing ceiling fan of any make or size complete all as specified and directed.
M/S RAJINDER SINGH
SHRI HARI BUILDERS
P.K. ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .