| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.9 L+₹2.0 L (7.54%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.5 L+₹2.5 L (9.60%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹29.2 L+₹3.2 L (12.5%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L4 | Rejected-AOC L4 | |
| 5 | L5₹29.8 L+₹3.8 L (14.6%)Rejected-AOC PLOT NO 184 SEC 3 IMT MANESAR GURGAON HARYANA 122050 | GURGAON | HARYANA | 122050 | L5 | Rejected-AOC L5 |
Tender Value
₹32.9 L
EMD Value
₹65,800
Closing Date
31 Jan 2023, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
SPECIAL REPAIRS TO EARTHING PITS AT CERTAIN PLACES AT AFS BEGUMPET UNDER GE(AF) HAKIMPET
2023_MES_572820_1
8477/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Begumpet
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Hakimpet
₹65,800
Yes
10 Mar 2023
3 Jan 2023
2 Feb 2023
3 Jan 2023
31 Jan 2023
17 Jan 2023
Amount
Supply & Fixing Air termination rod Aluminium of following sizes over existing RCC roof/AC sheet roof/GI sheet roof etc:-
(a) Dia 8mm Height 500mm
(b) Dia 8mm Height 700mm
© Dia 10mm Height 1000mm
(d) Dia 16mm Height 1500mm
(e )Dia 16mm Height 2500mm
(f) Dia 16mm Height 3000mm
Notes: (i) Air Termination rod shall be grouted rigidly in PCC all as directed by Engineer-in-Charge (ii) PCC for grouting shall be measured and paid seperately under separate item (iii) Air Termination rod shall be connected with aluminium strip using Stainless steel Clamps complete with nuts, bolts & washers, gitty etc., (iv) Cost of stainless steel clamp is deemed to be included in the quoted rate. (v) Air terminations having height of 2500/3000mm shall be supported on all four sides with galvanised stay wire of suitable dia. And the rate quoted is deemed to be included the cost of stay wire arrangement.
M&L for Plain cement concrete type C1, 1:3:6 using 20mm graded stone aggregate in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed.
Roof Conductor M&L Aluminium strip 25 x 3.15mm including percelian insulator/saddle and fixing screws, gitty, lord glue etc. for fixing roof conductors properly above ground. Note: Roof conductor shall be secured at not more than 1.20 metre apart using Percelian insulators/saddles.
Down Conductor M&L Aluminium strip 25 x 3.15mm with percelian insulator holder and fixing screws, gitty, lord glue etc etc. for down conductors above ground. Note: Down conductor shall be secured at not more than 1 metre apart using Percelian insulators/saddles.
Earthing M&L Galvanised iron strip 32 x 6mm fixed on walls with saddle or buried in ground from test link to the earth pit. Note : Quoted rate includes bending, making hole into strip/wall, nuts, bolts, washers, saddles/insulators etc
M&L Single core PVC insulated copper flexible cable 50sqmm size drawn through PVC conduit of suitable dia fixed over wall using saddles, copper lugs, brass nut bolts etc
M&L for Maintenance free earthing all as per following specification :- Make: DEHN/JEF TECHNO/PRAGATI
(a) Copper bonded rod with Low carbon steel, high tensile strength copper bonded rod with min 250 microns of copper plating, UL listed. Diameter- 17.2 mm, Length- 3 meters, Material- Copper Bonded, Coating thickness- 250 microns, min, Approvals- Tested acc. IEC / EN 62561-2, UL 467. (b) 20 kg backfilled compound, - Material Carbon based backfill/earthing compound, Fulgurite formation test at direct lightning (10/350 μm), lightning long duration test at- 100C No fulgurites/Pass, Environmentally Friendly ROHS certified, Resistivity- < 0.12 ΩM, Complying Standard- IEC 62561-7 , Testing Approvals Certified from- NABL accredited Laboratories. (c ) SS 316 grade Termination clamp to terminate the load on earth electrode for termination, Material of construction - 316 grade stainless steel, Dimension - 160x35x3 mm (d) Poly plastic pit cover of material- Polymer Body & Cover, Dimensions- 308 mm (L) x 308 mm (W) X 214 mm (H), Weight 2.5 kg (5.50 LBS).
Notes:- (a) Testing approvals/certificates copy shall be submitted to Engr-in-Charge. (b) Quoted rate includes complete earth work, making good etc (c) ER value of Single Earth pit shall be less than 3 Ohm. In case of more than 3 Ohm, additional earthing pits shall be made and interconnected with GI strip free of cost to bring down ER value to less than 3 Ohm (d) Earthing Resistance Testing shall be carried out using calibrated Earth Tester. The contractor shall bring Earth tester alongwith valid calibration certificate. (e) Strip/conductor from Earth pit to equipment/test point shall be measured and paid seperately.
M&L for Maintenance free earthing all as per item here-in above but including taking old U/S earth pits
NOTES : Notes for item No. 7 and 8:- (i) Earthing is to be done in front of the Engineer-in-charge. (ii)Test results of earthing to be submitted by the contractor for all earthing pits. (iii) The contractor shall have to give written guarantee for maintaining earth resistance of less than 1 Ohm for a period of 5 (Five) years after certified date of completion and shall deposit Rs.1500/- per earthing pit as security deposit for a period of 5(Five) years. (iv) Failing to maintain resistance of earthing pit less than 1 Ohm, new earthing pit to be provided by the contractor without any extra cost. (v) Necessary earth work excavation shall be carried out in any type of soil strata, returning, filling in and making good the surrounding area complete.
Internal Lightning Protection S&F Lightning current & Surge Protection Device at mains LT panel/DB (1 phase, 230 V) for (L-N) Single-pole combined lightning current and surge arrester, Type 1+2 SPD, Aprrovals: KEMA, SPD according to EN 61643-11 / IEC 61643-11.Spark gap technology with a width of only 1 module / pole allows compact and space-saving design. Make : DEHN/HAVELLS/LEGRAND/ABB
S&F Lightning current & Surge Protection Device at mains LT panel/DB (3 phase, 415 V) for (TP+N) combined lightning current and surge arrester, Type 1+2 SPD, Approvals: KEMA, SPD according to EN 61643-11 / IEC 61643-11. Make: DEHN/HAVELLS/LEGRAND/ABB
S&F Distribution Board SPN 2 way Single door complete with DIN rail for housing SPD (SP+N)
S&F Distribution Board SPN 4 way double door complete with DIN rail for housing SPD (TP+N)
M&L Sub main wiring complete with Two runs of 6 Sq mm Single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with One run of 6 Sq mm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including suitable size PVC casing and caping including accessories complete all as specified and as directed. Note: Three runs of 6 Sq mm + PVC casing caping with accessories measure as a one unit.
All as above item above but 2 runs of 10 Sqmm main wire + 1 run of 10 sqmm earth wire and casing and caping Note: Three runs of 10 Sq mm + PVC casing caping with accessories measure as a one unit.
All as above item above but 4 runs of 10 Sqmm main wire + 2 runs of 10 sqmm earth wire and casing and caping Note: Six runs of 10 Sq mm + PVC casing caping with accessories measure as a one unit.
SRI LALITHA CONSTRUCTIONS
KOGANTI CONSTRUCTION COMPANY
M/S - KRUPA ELECTRICALS
PRAGATI ELECTROCOM PVT LTD
VACON INFRASTRUCTURES
POWER CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .