| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹44.8 L+₹3.3 L (8.06%)Rejected-AOC VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC NOT ACCEPTED | |
| 3 | L3₹45.8 L+₹4.3 L (10.4%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED | |
| 4 | L4₹46.9 L+₹5.4 L (13.0%)Rejected-AOC 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹47.6 L
EMD Value
₹95,200
Closing Date
4 Dec 2019, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR C/0 56 APO
ADDN/ALTN TO BLDG NO NP38 CP COLONY CERTAIN DRAINS AND HARD STANDINGS AT COMD MT COMPLEX AT UDHAMPUR PROVN OF ROOF TREATMENT AND CERTAIN ALLIED WORKS IN BLDG NO P130 AT NC OFFRS MESS FLOOR TILES OF CLASSROOMS AND OFFRS IN BLDG NO P52 HRDC AND MINOWK
2019_MES_295400_1
GE/S(U)-45/2019-20
Open Tender
Civil Works
Item Rate
240 days
CP COLONY NC COMD UDHAMPUR
REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH UDHAMPUR
₹95,200
Yes
5 Mar 2020
6 Nov 2019
5 Dec 2019
6 Nov 2019
4 Dec 2019
20 Nov 2019
6 Nov 2019 - 13 Nov 2019
Amount
Dismantling Asbestos cement (corrugated or semi corrugated) sheets as in roof covering complete all as specified and directed.
Pre-painted galvatume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Pre-painted galvatume aluminum zinc coating GI vased Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed.
MS flat iron as in wind ties etc confirming to Fe 410-0 or Fe 310-0 including clamps complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position and in un framed work complete all as specified and directed.
Rolled section as in main and cross beams, purlins, rafters, posts where connected to common rafter and running rails, eves board framing work, tank staging work etc confirming to Fe-410-W complete all as specified and directed.
1.25 mm thick plain black mild steel sheeting in ridges hip, valley gutters drip and gutters and straight flashings (Length and girth as fixed) fixed as in repair complete all as specified and directed.
Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members, frame etc complete all as specified and directed.
Providing false ceiling GI frame work for seamless ceiling comprising of GI perimerter channel 0.55 mm thick with two unequal flages of 20 to 30 mm and web of 27 mm fixed to surrounding wall using screws at 450 mm C/C channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm c/c with GI cleat and steel expansion or suitable hanging from soffits\trusses\bracking supporting hanger compressing of GI wire complete all as sepcified and directed by Engr-in-Charge.
4 mm thick 600 x 600 mm size asbestos cement plain E-boards designer ceiling (Make: Everest of equvalent), fixed to GI grid work with screws and applying new surfaces two coat of distempers and one coat of primers complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipe 100 mm dia and below jointed in cement mortar and taking out of floor/walls etc complete all as specified and directed.
110 mm PVC (SWR) pipes single socket in any lenth with rubber ring joints fixed to wall complete all as specified and directed.
110 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
110 mm PVC (SWR) branch piece, (singal Y) equal or unequal with access door complete all as specified and directed.
Rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres including all accessories complete all as specified and directed.
PTMT ball valves 20 mm dia high pressure with epoxy coated aluminium rod and high denscity plastic ball screwed for iron pipes and fixed to iron pipes complete all as specified and directed.
Gun metal globe or gate valve 20 mm, with iron wheel head screwed both ends for iron pipe and loud in repairs complete all as specified and directed.
Complete removal of existing treatment and applying two coats of oil bound distemper over a coat primer with two coat of wall care putty complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floor and paving not exceeding 25 cm thickness below and above ground level and as in floor complete all as specified and directed.
Removing excavated soil/debries form site to a distance exceeding 50 m and not exceeding 1.50 km out side defence land complete all as specified and directed.
150 mm thick PCC 1:4:8 type B-2 (using 40 mm graded aggregate) as in sub base of floor etc complete all as specified and directed.
100 mm thick plain cement concrete 1:2:4 (Nominal Mix) type B-1 (using 20 mm graded stone aggregate) as in floor, including top surfaces of the concrete chequered finish whilst the concrete is green complete all as specified and directed by Engr-in-Charge.
Forming 6 mm thick and 100 mm deep expansion joint filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade 'A' complete all as specified and directed.
Preparing existing black top surface by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc complete all as specified and directed.
Premix bituminous macadam using paving bitumen any penetration @ 4 % by weight of total mix laid/rolled compacted to required gradient and camber (consolidated thickness 75 mm or less) complete all as specified and directed.
Applying evenly a priming/Tack coat with bituminous primer at 5 Kg per 10 Sqm using paving bitumen on existing black top surface complete all as specified and directed.
Bituminous premix semi dence asphaltic concrete 30 mm consolidated thickness with 5.5 % binder content (using paving bitumen any penetration) by weight of total mix rolled and compacted to reaquired camber and gradient complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar complete all as specified and directed.
Plain cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in channels and drains, foundation and similar work etc complete all as specified and directed.
PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in coping, benching and similar work etc including necessary form work complete all as spcified and directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:4) as in drain, walls and similar work etc complete all as specified and directed.
Rendering 15 mm thick on brick or concrete surfaces of walls in cement mortar (1:4) including finishing the surfaces even and smooth without using extra cement as in drain etc and similar work complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding and any type of existing roof treatment complete all as specified and directed.
Roughening surfaces of old concrete floor by picking sweeping cleaning and washing down with water to remove dust etc including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 kg/Sqm complete all as specified and directed by Engr-in-Charge.
PCC 1:2:4 type B-1 (using 12.5 mm graded aggregate) as in level course on roof surface 25 mm thick etc complete all as specified and directed.
Rendering 10 mm thick in cement mortar 1:3 mixed with integral water proofing compound as per manufacture's instructions as in roof and chajjas, finished the surface fair and even with out using extra cement complete all as specified and directed. Note : Supply of water proofing compound will be measured and paid separately.
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Minimum weight of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm including two coats of bituminious alluminium paint complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound complete all as specified and directed.
15 mm thick screed bed in cement mortar 1:6 for laying floor finishes under floor complete all as specified and directed.
Vitrified ceramic tiles (Double charge shed approved by GE), area of each tile not exceeding 0.36 sqm, 10 mm thick (square or rectangular) of superior quality as in floor surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 on vertical surfaces/backing coat complete all as specified and directed.
Glazed ceramic coloured tiles of size 300 x 600 x 7 mm/450 x 300 x 7 mm wall tiles set and jointed in neat cement and in white/coloured cement to match with the colour of tile etc complete all as specified and directed.
110 mm PVC (SWR) couplers for PVC pipe and similar work complete all as specified and directed.
Disconnecting existing tanks of exceeding 500 but not exceeding 1000 ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position with cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes etc complete all as specified and directed.
Taking down cement plaster and raking out joints, hacking for key, scrubbing down with water built in cement mortar complete all as specified and directed.
Preparation of new plaster surface of walls and applying two coat of oil bound distempers over one coat of primer and a coats of wall care putty complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment (using removal machine) including preparing surfaces of wall and applying two coats of weather proof exterior emulsion paint (APEX or equivalent) over a coat of wall care putty up to G+2 floor height etc complete all as specified and directed.
Taking down chowkhat or frames with shutters exceeding 1.5 Sqm each and not exceeding 4 Sqm each and fixing the same complete all as specified and directed.
Demolition of cement concrete is ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floor, mass concrete or similar work complete all as specified and directed.
Vitrified ceramic tiles 10 mm thick 1st quality (Square/rectangular) polished, light shade area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed with neat cement slurry to match over 20 mm thick screed in cement mortar 1:6 complete all as specified and directed.
Glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm/450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white/colour cement to match over and including 15 mm thick screed bed cement mortar 1:4 complete all as specified and directed.
Non skid coloured ceramic tiles 7 to 8 mm thick in skirting/dado (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
Applying 3 mm thick wall care putty on wall surfaces and well rubbing for making smooth and uniform surface with sand paper then applying two coats of oil bound distemper in different patterns shade with rolling instrument including a coat of primer on decorative surfaces etc. complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment on walls and applying two coats distemper oil emulsion over a coat of primer on walls complete all as specified and directed by Engr-in-Charge.
Complete removal of existing treatment on walls and applying two coats of cement base paint complete all as specified and directed by Engr-in-Charge.
False ceiling with 12 mm thick glass fibre reinforced Gypsum ceiling tiles of size 595 x 595 mm, prima fine fissured micro look white coloured using aluminium powder coated "T" section 25 x12 mm grid and 6 mm dia GI suspension wire etc complete all as specified and directed. Make : Armstrong/Diamond or equivalent.
Preparation of old surface and applying two coat APPEX paint including 3 mm thick wall care putty complete all as specified and direction by Engr-in-Charge.
Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification and drawing complete all as specified and directed by Engr-in-Charge.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frames made out of M. S. tubes for top and bottom rails. M. S. frame shall be covered with heat moulded plain colourPVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside withsolvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with slovent cement, suppling and fixing in the frame at site as per specification and drawing complete all as specified and directed by Engr-in-Charge.
200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed in repair complete all as specified and directed by Engr-in-Charge.
Butt hinges ISI marked 100 mm size, medium weight, cold rolled mild steel complete all as specified and directed.
125 mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engr-in-Charge.
Mild steel framed work of grade confirming to Fe 290 Gde-E-164 as in guard bars, grills, barred iron doors, ladders, railings, frame work for water tanks and similar work complete all as specified and directed by Engr-in-Charge.
Wash hand basin vitreous china flat back 550 x 400 mm size white including PVC waste coupling 32 mm size, PVC waste pipe 32 mm bore, pair of brackets of mild steel 35 x 35 x 6 mm size including one CP pillar tap cast copper alloy 15 mm bore, one brass stop valve 15 mm bore and one PVC connection 15 mm size with PTMT nuts of length 450 mm long fixed as in repair complete all as specified and directed by Engr-in-Charge.
Wash down water closet squatting pan 'Orissa pattern' white 580 x 440 mm size including integral foot rest, PVC flushing cistern 10 liters low level PVC waste pipe suitable to joint flushing cistern to water closet fixed on 'P' or 'S' trap complete all as specified and directed by Engr-in-Charge.
Vitreous China Urinal, half stall type whiteincluding Urinal spreader of PTMT, PVC waste fittings 32 mm size, PVC connection of 15 mm size with PTMT nuts of length 450 mm long including bracket complete all as specified and directed by Engr-in-Charge.
Cast iron floor trap 75 mm bore including 100 mm round CP brass grating including jointing to waste pipe in run lead and set in cement concrete 1:2:4 type B-1 (using 12.50 mm coarse aggregate ) complete all as specified and directed by Engr-in-Charge.
CI soil waste and vent pipes 100 mm bore size sand cast in any length with or without ears with cement joints laid in floors complete all as specified and directed by Engr-in-Charge.
All as per ser item No 70 hereinbefore but 75 mm bore complete all as specified and directed.
Cast iron bends any radius, dimishing pieces or traps 100 mm bore size complete all as specified and directed by Engr-in-Charge.
Cast iron bends any radius, dimishing pieces or traps 75 mm bore size complete all as specified and directed by Engr-in-Charge.
Low level PVC flushing dual type 10 ltr capacity including flushing pipe complete all as specified and directed by Engr-in-Charge. Make : Commander/Parryware (Slim).
Taking up or down steel tubing and connections 15 mm dia, including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-Charge.
All as per ser item No 75 hereinbefore but 20 mm dia complete all as specified and directed by Engr-in-Charge.
Steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, 15 mm bore complete all as specified and directed.
All as per ser item No 77 hereinbefore but 20 mm dia complete all as specified and directed by Engr-in-Charge.
Dismantling water tanks exceeding 500 and not exceeding 1000 complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard and dense soil complete all as specified and directed.
75 mm thick PCC 1:4:8, type D-2 by (using 40 mm graded stone aggregate) as in sub base floor complete all as specified and directed.
Sand cushion 20 to 30 mm thick for laying and fixing interlocking tiles complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (glossy finish) any shape and size (approved by GE) confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment complete all as specified and directed by Engr-in-Charge.
Precast cement concrete (factory made) 1:2:4 type B-1 (20 mm graded stone aggregate) set in cement mortar as in road kerbs, coping, benching and similar work etc complete all as specified and directed.
Hand rails, half rounded or other steel section, posts and struts in fencing including cutting tops to shape as directed, angle iron work for ladder up to G+2 floor, water tank staging with guard cover, purline and rafter work, including drilling holes, notching for wire including all necessary drilling, bolting or riveting etc and similar work complete all as specified and directed.
Preparation of new steel surfaces of any descripton not otherwise described over 10 cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide on steel surfaces complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation and getting out in any type of soil complete all as specified and directed.
Brick work with sub class B bricks, straight or curved on plan exceeding 6 m mean redius built in cement mortar 1:6 complete all as specified and directed.
Reinforced cement concrete (nominal mix) type B-1 1:2:4 (using 20 mm graded aggregate) using in beams, cantilevers, bressummers, lintels over 1.5 mtr span and similar work etc. complete all as specified and directed.
Form work to sides of lintels, beam haunching, girders lintal cantiliver including supports overhangs etc complete all as specified and directed.
TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for colums, hooking ends and including mild steel wire not less than 0.9 mm dia or securing with clips quality confirming to TMT bars complete all as specified and directed.
Precast cement concrete louvres and jallies 50 mm thick set in cement mortar 1:6 type B-0 (1:2:4) (using 12.5 mm graded aggregate) etc sample as approved by GE and complete all as specified and directed by Engr-in-Charge.
Preparation of new plastered or un- plastered surfaces and walls including cornices, pilasters etc and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Returning and filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm in hard dense soil complete all as specified and directed.
Taking down carefully, copper/aluminum point wiring (light, fan, socket or power) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable in and including not less than 2.00 mm thick 20 mm dia and over Non metallic Rigid PVC surface/ Concealed Conduit (ISI marked) with and all accessories 1.5 mm thick mild steel terminal boxes concealed on walls, painting the same inside and out side with one coat of black bitumen paint with 3 mm thick hylam brand bakelite sheet cover for fixing of piano switches/sockets/regulator etc along with PVC insulated and unsheathed FRLS 1.00 sqmm multi stranded copper conductor cable (green color) as earth lead and connected to common earth and earthdolly, making good the disturbed surface to match with the existing specification complete all as specified and directed by Engr-in-Charge. Make - KEI or equivalent make in polycab /finolex
All as per ser item No 96 but for one 3 pin 5 Amp socket outlet point controlled by one push button on same board complete all as specified and directed. Make - Anchor or equivalent make in polycab/ Havells
All as per ser item No 96 but for one 3 pin 5 Amp socket outlet point controlled by one push button on independent board complete all as specified and directed. Make - Anchor or equivalent make in polycab/Havells
All as per ser item No 96 but for one 3 pin 15A socket outlet on independent Board with PVC insulated unsheathed FRLS cable 2.5 sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and directed. Make -Anchor or equivalent make in polycab /finolex
Switch piano flush button single pole one way 5 amps 240 volt fixed as in repair complete all as specified and directed.
Socket outlet 2 in 1, 3 pin, 5A, 240 Volt fixed as in repair complete all as specified and directed.
Switch socket combination 5 Amps 2-in-1, 5 Pin flush type, 230 volts fixed as in repair complete all as specified and directed.
Switch socket combination 5 pin 16 amp, flush type fixed as in repair complete all as specified and directed.
Ceiling rose surface bakelite 3 terminals fixed as in repair complete all as specified and directed. Make : Cona, Cat Part No 2126/SSK Cat Part No 572 or equivalent of make in Havells/Anchor/Kolors.
Fan regulator electronic, stepped type hum free suitable control speed of fan from 0 to 100 % and connecting electrically fixed as in repair complete all as specified and directed.
Sheet metal enclosure MCB distribution board single pole and neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
Replacement MCB Single Pole, 230 Volt, Raiting 6 to 32 Amps complete all as specified and directed. Make : Indoasian, Cat Part No : 811015 or equivalent Havells/Legrand
Replacement MCB Single Pole and Neutral, 230 Volt, Raiting 35 to 63 Amps complete all as specified and directed. Make : Indoasian, Cat Part No : 811037 or equivalent Havells/Legrand
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 2.5 Sq mm as earth lead complete all as specified and directed. Including taking down old sub main wire.
Taking down ceiling/Exhaust fan including disconnection of existing connection, dismanting of blades and Painting of fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and rehanging the fan complete all as specified and directed.
Replacement New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 20 W Make - Havells Cat Part No LHEXBXPNIN1W020 or equivalent to Polycab/HPL/Bajaj complete all as specified and directed by Engineer-in-Charge.
Replacement of LED bulk head luminaire, 10 W (ENDURA RUGBY) Make - Havells Cat Part No. LHEOAOP7UZ6W010 230 Volts wall/ surface mounted complete with LED lamp 10 watt, with all accessories, pre-wired, including providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.
LED CANIS/9W Bollard light with opal diffuser and aluminium reflector complete all as specified and directed. Make : C&S Cat Part No : LTGLCW9WLED or equivalent HPL/Bajaj
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, check, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete all as specified and directed as shown in electrical plate No 5 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion.
KALSOTRA CONSTRUCTION CO
khajuria builders
VARDHMAN INTERNATIONAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .