Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC HOUSE NO 1872 SECTOR 13 17 HOUSING BOARD COLONY PANIPAT 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | L1 | Accepted-AOC Ok | |
| 2 | L2₹2.0 L+₹14,039 (7.61%)Rejected-Finance 20 VPO KALAYAT 136027 | KALAYAT | KAITHAL | HARYANA | 136027 | L2 | Rejected-Finance Rejected |
Tender Value
₹1.8 L
EMD Value
₹3,540
Closing Date
13 Jun 2022, 10:00 amClosed
Executive Engineer
Executive Engineer Pundri W/S Division Kaithal
Special repair of slab of staff room RD. 279000 Sirsa Branch
2022_HRY_224787_2
4857-81 /14-A dated 07.06.2022
Open Tender
Civil Works
Item-rate/Agreement basic
30 days
Kaithal
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹3,540
Yes
15 Jul 2022
8 Jun 2022
13 Jun 2022
8 Jun 2022
13 Jun 2022
8 Jun 2022
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge : Nominal concrete 1 :2:4 or leaner mix (i/c equivalent design mix) (HSR 5.23.2)
EartDemolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar (HSR 5.7.4).
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR No.7.20.1)
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies (HSR No.6.30.3)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , xcluding overlaps. Wastage, overlaps, couplings, welded joints,acer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.33.6)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size) (HSR 6.14.1)
12 mm cement plaster of mix : 1 :3 (1 cement: 3 fine sand) (HSR 11.5.2)
Providing and laying Cement concrete flooring 1: 2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete : 40 mm thick with 20 mm nominal size stone aggregate (HSR 10.10.1)
Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1 :3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1 :3 (1 cement : 3 fine sand) and finished neat: With common burnt clay non-modular brick tiles of class designation 10 (HSR 9.14.1)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete : Size of Tile 500x500 mm (HSR 10.63.1)
Providing & laying average 6mm thick POP Coating on walls, Ceiling, beams and lintels etc. complete in all respects as approved by the Engineer-In-Charge. (HSR 11.57)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer (HSR 11.64.1)
Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work (HSR 11.71.1)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Lettering with black Japan paint of approved brand and manufacture. (HSR 11.113)
Credit of steel scrap.
Sanchit
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .