Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹1,840 (0.02%)Rejected-AOC | ₹1.1 Cr+₹1,840 (0.02%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.1 Cr+₹17,840 (0.17%)Rejected-AOC | ₹1.1 Cr+₹17,840 (0.17%) | L3 | Rejected-AOC L3 |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
20 Jan 2021, 4:30 pmClosed
Sri Hridoy Boro
O/o the Addl. Chief Engineer cum Director, PWD, Kokrajhar
Const of G plus 1 RCC Office Building for Accommodation of Assistant Director FCS CA Office at Bijni Sub Division 2 nd phase works
2021_BTC_19967_1
No. ACE- 05/CHN/IFB/2018-19/244
Open Tender
Civil Works - Building
Item Rate
540 days
Bijni
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,200
The Principal Secretary, BTC, Kokrajhar
₹2.1 L
Yes
11 Mar 2021
6 Jan 2021
21 Jan 2021
6 Jan 2021
20 Jan 2021
6 Jan 2021
6 Jan 2021 - 20 Jan 2021
Amount
A) Construction of Ground Floor Balance Work: 1st class brick nogged wall in cement mortar including racking out joints and curing out joints complete as directed in super structure above plinth up to 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately). A) 112mm thick brick wall. (a) In cement mortar in proporation 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Providing fitting and fixing powder coated pressed steel door fram made of 1.25mm / 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jumb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20×20×1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc. complete as directed by the department for all levels. (P.C.C. to be measured and paid for separately). (b) 1.60 mm thick sheet (iii) Size 125mm × 60mm (Single rebate)
Providing fitting and fixing factory made Santro Flush door shutter having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens. 2.5mm to 3.5mm uniformly thick cross bands. Styles & rails made from hardwood timber of width not less than 50mm. fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid separately). (c) 40 mm thick.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standerd sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specification) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangement, screws etc as required complete and directed for all levels. (b) 3 Track sliding window (i) 6mm clear glass
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S. butt hinges (100mm×75mm×3.55mm) with necessary screws (other fittings to be measured and paid separately) c) With 1st class Local wood ( Bola wood) (ii) 35mm thick
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick wall and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceilings surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Wall painting ( two coat) with plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint of approved brand and manufacture (Asain paint/Berger paint/ICI paint/J & N paint/Nerolac).
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paint and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all level (two coat)
Providing VIRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirting, risers and tread of steps over 15mm thick base of cement mortar in prop 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved) a) Normal range Somany/ Orient/ Nicto/ Varmora/ VITA/ Marbito/ Make iii) Of size 600mm×600mm and above
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement : 3 coarse sand) approved make fix with Fix-A-tile (Choksey/Sika/Pedelite/Rouf) / white cement complete at all level as specified and directed. (A) CERAMIC i) Normal range (Size 300mm × 300mm and above) (a) Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galuxy green, Pulsar Beige, Pulsar Blue
Providing polished ceramic wall tiles of approved quality, size shape and thickness not less than 8mm on wall and skirtings over cement mortar bed 10mm thick in prop 1:3 ( 1 cement : 3 coarce sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf ) / white cement slurry mixed with approved pigment to match shade of tiles complete at all level as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Wall means both interior and exterior walls) a) Normal range i) Of size 200mm x 200mm and above.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint, wood primer (Pink)
Painting two coat (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. b) High gloss (Asian paint / Beger paint / ICI paint / J & N paint / Nerolac)
Supplying, fitting, fixing anodised aluminium fitting of approved make, resonably smooth, free from sharp edges and corners, flows and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt 7 satin finished) a) Sliding door bolts i) 300mm × 16mm
Supplying, fitting, fixing anodised aluminium fitting of approved make, resonably smooth, free from sharp edges and corners, flows and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt 7 satin finished) (b) Tower bolts (ii) 250mm × 12mm
Supplying, fitting, fixing anodised aluminium fitting of approved make, resonably smooth, free from sharp edges and corners, flows and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt 7 satin finished) (c) Door handles (iii) 150mm
Supplying, fitting, fixing anodised aluminium fitting of approved make, resonably smooth, free from sharp edges and corners, flows and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt 7 satin finished) (h) Mortice night latches (i) Rim latches (iii) 150mm
Supplying, fitting, fixing anodised aluminium fitting of approved make, resonably smooth, free from sharp edges and corners, flows and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt 7 satin finished) (d) Gate shutter hook & eye (iv) 250mm
Providing from work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horaizontal ties. (a) For depth not exceeding 1.0M.
Providing from work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3 Flat Surface such as soffits of suspended floors, roofs, landings, cantilever slab, chajjas. balconies and...... (a) Floors etc. upto 200mm in thickness
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chair, spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement work ( from work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. (N) Without using admixture, plasticiser (ii) Columns, pillars, post, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing) including preparing the top surface and finishing of nosing. (N) Without using admixture, plasticiser (b) M20 grade concrete or prop 1:5.5:3
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flat at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (a) Fixed to wooden frames
Supply, Installation, fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10kg)
Providing and laying controlled cement concrete pavement of approved grade with 20mm down graded stone aggregate over a prepared sub-base including dewatering if necessary, spread, compacted and finished in a continuous operation including provision of construction and expansion joints, plasticiser and curing compound of Fosroc/ Sika/ Choksey/ Degusa and hardener of Recron/ Degusa/ Fosroc; finishing to lines and grades and curing as specified and directed complete ( from work and reinforcement shall be measured and paid separately) (a) M20 Grade concrete
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. C) 100 mm thick
Providing soiling in foundation and under floor, with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a). Brick on flat soling
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc complete as directed.
Providing plinth protection with brick flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with the floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shattering for sides and earth work in excavation of foundation trenches and refilling the side after completion of work etc. as specified. (i) 300mm wide and average 150mm deep with bed slop 1 in 150 with initial depth of 100mm
Providing precast R.C.C. slab over drain, septic tank etc. in prop 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering, curing etc. complete including fixing in position as directed. b) 75mm thick slab
SANITARY FITTINGS Providing fitting and fixing vitreous china predestal type water closet (European type W.C. pan 400mm high) with seat and lead, CP brass hinges and rubber buffers. CI/MS brackets, 40mm dia flus band with fitting including painting of fittings and brackets, required (Flushing Cistern to be paid separately) A) Parryware make a) White (i) Universal Closet S Trap (Cat No. C0271) (Anglo Indian) (inclusive of seat cover)
Supplying, fitting and fixing concealed cistern with all internal fitting with CI brackets with CI brackets including fitting and fixing standard size CP flus pipe, union clamps etc. complete as dorected and specified ( pipe will be measured separately) (i) Parryware make (i) Rios with Chorme Push Plate (Cat no.8174 / Cat. No.C813726)
Providing, fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the wall & floors wherever required. (A) Parryware make (a) White Integrated EFS-Smart DC (Cat No.C8182) / Integrated EFS-Smart AC with power source (Cat No.C819)
Providing vitreous China wash basin with CI/MS bracket, C.P. brass chain with plug. PVC waste pipe including painting of fitting and brackets, cutting and making good the wall wherever required, (Pillar cock, stop cocks, wast coupling are to be paid separately) PEDESTAL BASIN (with pedestal) (A) Parryware Make (a) White (i) Duke 660 × 495 (Cat No.C8416/27) (white/coloured)
Supplying, fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fitting such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed on walls d) 25 mm dia (Medium) (i) Using TATA make
Supplying, fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P. pipes will be measured separately) Essco make (Delux/Sumthing spl./Tropical) (b) Long body bib cock with wall flange
Supplying, fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipe will be measured and paid separately) (I) Brass stop cock (heavy) of sant make (iii) 25 mm dia
Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (ii) 110m dia
Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (iv) 75mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including, joining, fitting and fixing etc.as necessary complete at all levels including below G.L. as directed and specified. (ii) 110mm dia
Supplying fitting and fixing PVC Plain single tee ofn (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified). Ii) 110mm dia
Supplying, fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.I. as directed and specified. (ii) 110mm dia.
Supplying, fitting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining, fitting atc. In exposed surface or trences complete at all levels including below G.L. as directed and specified. (ii) 110mm dia.
Providing, fitting and fixing PVC cowel of ISI make complete as directed and specified. (b) 75mm dia.
C.P. Grating (ii) 100mm dia.
C.P. Grating (b) 75mm dia
Construction of inspection pit inside measurement 450 mm × 450 mm × 450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm × 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying, fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. fitting such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L.as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equavalent approved brand (High presure pipe Sch-40) (d) 25mm dia
Supplying and fitting fixing C.P. pillar cock of 15mm dia. of approved brand as specified and directed. Jaguar make (a) Continental
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. (b) 40 mm dia.
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. C) 25 mm dia.
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. (e) 15 mm dia.
Supplying, fitting and fixing gun metal check valve including necessary threads to pipes. (b) 40 mm dia. (Heavy type)
B) For Vertical Extension of First Floor: Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down draded stone aggregate including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (from work and reinforcement will be measured and paid separately) (B) in super structure from plinth level up to 1st floor level. b) M20 grade concrete or prop. 1:1.5:3
1st class brick nogged wall in cement mortar including recking out joints and curing completen as directed in super structure above plinth up to 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80 mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20×20×1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc. complete as directed by the department for all levels. (P.C.C. to be measured and paid for separately) (b) 1.60mm thick sheet (iii) Size 125mm × 60mm (Single rebate)
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross band fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross band, styles & rail made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid separately.) C) 40mm thick
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standerd sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specification) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangement, screws etc as required complete as specified and directed for all levels. (b) 3 Track sliding window (i) 6mm clear glass
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (i) TMT Corrosion resistant steel (CRs) reinforcement bar.
Providing from work ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.3-Columns, Pillars,Posts & Strut (a) Square, Rectangular, polygonal in plain or any shape like Tee/L etc. having plane vertical face (b) using 25mm thick plank
Providing from work ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.4-Sides and Soffits of Beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties. (ii) Using 25mm thick plank
Providing from work ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.5-Flat Surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies and the like. (a) floors etc. upto 200mm in thickness. (i) Using 38mm thick plank
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick wall and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceilings surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coat)
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirting, risers and treads of steps over 15mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/ Nitco/ Varmora/ VITA/ Marbito/ Make (ii) Of size 600mm × 600mm and above
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt & satin finished) a) Sliding door bolts (i) 300mm × 16mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt & satin finished) b) Tower bolts (ii) 250mm × 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt & satin finished) c) Door handles (iii) 150mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt & satin finished) h) Mortice night latches (i) Rim latches (iii) 150mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. ( anodised to bright natural matt & satin finished) d) Gate shutter hook & eye (iv) 250mm
Supply, Installation, fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4947 with ISI Mark, Powder will be confirming to IS: 4308 with ISI Mark (10) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flat at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (a) Fixed to wooden frames
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (b)With ready mixed paint, wood primer (pink)
Painting two coat (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (i) Surface over 100mm in width or girth. (b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Grading roof for water proofing treatment with (a) Cement concrete 1:2:4 (cement: 2coarse sand: 4 graded stone agg. 20 mm nominal size)
SANITARY FITTINGS Providing fitting and fixing vitreous china predestal type water closet (European type W.C. pan 400mm high) with seat and lead, CP brass hinges and rubber buffers. CI/MS brackets, 40mm dia flus band with fitting including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) White (i) Universal closet S Trap (cat No.C0271) (Anglo Indian) (inclusive of seat cover)
Supplying, fitting annd fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flus pipe, union clamps etc. complete as directed and specified (pipes will be measured separately) (i) Parryware make (i) Rios with Chorme Push Plate (Cat no.8174/ Cat. No. C813726)
Providing, fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. A) Parryware make a) White Integrated EFS-smart DC (Cat No.C8182) / Integrated EFS-smart AC with power source (Cat No.C819)
Providing vitreous China wash basin with CI/MS bracket, C.P. brass chain with plug. PVC waste pipe including painting of fittings and brackets, cutting and making good the wall wherever required, (Pillar cock, stop cocks, wast coupling are to be paid separately) PEDESTAL BASIN (with pedestal) (A) Parryware Make (a) White (i) Duke 660 x 495 (Cat. No.8416/27) (white/coloured)
Supplying, fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fitting such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed on wall d) 25mm dia (Medium) i) Using Tata make
Supplying, fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P. pipes will be measured separately) Essco make (Delux/Sumthing spl./Tropical) (b) Long body bib cock with wall flange
Supplying, fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipe will be measured and paid separately) (I) Brass stop cock (heavy) of sant make (iii) 25 mm dia
Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (ii) 110m dia
Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (iv) 75mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including, joining, fitting and fixing etc.as necessary complete at all levels including below G.L. as directed and specified. (ii) 110mm dia
Supplying fitting and fixing PVC Plain single tee of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified) (ii) 110mm dia.
Supplying fitting and fixing PVC resucer of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (ii) 110mm dia
Supplying fitting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. (ii) 110mm dia.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (b) 75mm
C.P. Grating (ii) 100mm dia.
C.P. Grating (b) 75mm dia
Construction of inspection pit inside measurement 450 mm × 450 mm × 450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soiling, 12 cm brick wall in cement mortar in prportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor 450mm × 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing approved uPVC Pipes of different size, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, Tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all level including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equivalent approved brand (High presure pipe Sch-40) d) 25 mm dia
Supplying and fitting fixing C.P. pillar cock of 15mm dia. of approved brand as specified and directed. Jaguar make (a) Continental
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. B) 40mm dia
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. C) 25 mm dia.
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. (e) 15 mm dia.
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. (b) 40mm dia (Heavy type)
C) R.C.C. Staging with over head Tank: Earthwork in excavation for foundation trenches of wall, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifs as directed and specified in the following classification of soil including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soiling in foundation and under floor, with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soiling.
Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately) (a) In rpop 1cement : 3 sand ; 6 coarse aggregate by volume
Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement work ( from work and reinforcement will be measured and paid separately). (A) In substructure uo to plinth level. (N) Without using admixture, plasticiser (b) M20 grade concrete or prop. 1:1:.5:3
Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement work ( from work and reinforcement will be measured and paid separately). (B) In super structure from plinth level up to 1st floor level. (b) M20 grade concrete or prop. 1:1.5:3
1st class brick nogged wall in cement mortar including racking out joints and curing completen as directed in super structure above plinth up to 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (b) In cement mortar in prportion 1:5
10 mm thick Cement plaster in single coat on fair side of brick/concrete wall for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side c) In cement mortar 1:5
15 mm thick Cement plaster in single coat on half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not excedding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
Providing from work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain. 3.2.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc.
Providing from work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain. 3.2.1.2 Side and soffits of Beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties (a) For depth not exceeding 1.0M
Providing from work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain. 3.2.1.3 Flat Surface such as soffits of suspended floors, roofs, landings, cantilever slab, chajjas, balconies and the like. (a) Floor etc. upto 200mm in thickness
65mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 ( 1cement : 1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panel and finished with floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg per square metre of floor area) including curing etc. complete as directed.
Providing undressed wood work in roof truss, refter, purlin, tie and the like including hoisting and fixing in position with necessary spikes, nails including M.S. straps with bolt and nuts etc. complete with kiricide oiling two coat to all timber member and two coat of anticorrosive paint to M.S. staps (M.S. flat, angle cleat, and bolt and nuts required for flat and angle cleat wherever used (b) With Hollock/ Sundi/Sam
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia × 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (b) 0.50 mm thick
Providing galvd iron ridging of TATA SHAKTEE / SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (ii) 230 mm lapping
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coat) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangemnt including providing pads of size as required for intel and outlet pipes 500 litre capacity. (a) Sintex make
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed (b) ITC / NEZONE / Bansal/Jindal (Medium) (v) 40 mm diameter
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed. (iii) 25 mm diameter
Labour for erecting and placing PCVC Tank over the stagging up to height of 8.00m complete as directed. (d) 500 litre.
D) Construction of Garage: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water necessary as directed and... (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Providing soiling in foundation and under floor, with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a). Brick on flat soiling
Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid (a) In prop 1cement: 3 sand: 6 coarse aggregate by volume
Providing from work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1-Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
Providing from work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.2-Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
Providing from work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.3-Column, Pillars, Post & Strut. (b) Using 25mm thick plank
Providing from work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.4-Side and Soffits of Beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties. (b) Using 25mm thick plank
Brick work in cement morter with 1st class bwick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.x (a) With earth or silt or sand obtained by head load with lead upto 90mm and lift upto 2m
1st class brick nogged wall in cement mortar including racking out joints and curing completen as directed in super structure above plinth up to 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid (A) 112mm thick brick wall (b) In cement mortar in proportion 1:5
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and including curing complete as directed. A) On rough side c) In cement mortar 1:5
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and including curing complete as directed. B) On fair side c) In cement mortar 1:5
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1 ltrs of paint with 1 ltrs o water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the
Wall painting ( two coat) with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar dropping and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate promer and two coat of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joints as per design and drawing as directed. b) Using other ISI marked approved circular hollow section. 50 mm
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia × 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately). (c) 0.55 mm thick
Labour for fitting and fixing Galvd corrugated iron roofing including supplying and fixing with new galvd screw, J hook, bolts nuts, washer etc. complete as directed
65 mm thick cement concrete floore consisting of 50 mm under layer of cement concrete in prop. 1:3:6 ( 1 ccement : 3 coarse sand : 6 coarse aggregate of 25 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 ( 1 cement ; 1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panel and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including
Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement work ( from work and reinforcement will be measured and paid separately) (A) In substructure up to plinth level Foundation, footing, column with base tie and plinth beam, pile cap, base slab, retaining wall, wall of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or prop. 1:1.5:3
Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement work ( from work and reinforcement will be measured and paid separately) (B) In super structure from plinthb level up to 1st floor level a) M20 grade concrete or prop. 1:1.5:3
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed blackwire and placing in position with proper blocks, supports, chairs,spacers etc. complete. (No extra measurement foe lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (upto 1st floor level) (b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain. works, retaining wall & boundary wall etc.
Providing plinth protection 50mm thick cement concrete 1 : 3 :6 with coarse agg. Of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary the side after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slop 1 in 150 with initial depth of
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc.
E) Septic Tank: Earthwork in excavation or foundation trenches of wall, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work breaking clods in return filling, dressing, watering and remming etc. and removal of surplus earth with all lead and lift as directed and specified in the following of soils including bailing out water where necessary as directedand specified (A) Up to a depth of 2.00m below the existing ground level (a) In ordinary soil
Providing soiling in foundation and under floor, with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls,brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand: 6 coarse aggregate by volume
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper block, supports, chairs, spacers etc. complete a) From Primary Producer: TATA/SAIL/ESSAR Steel/ Jindal steel/Shyam steel/RiNL (i) TMT Corrosion resistant steel (CRS) reinforcement bar 10mm dia bars
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
Providing from work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain. Columns, Pillars, Posts & Strut of square/rectangular/ polygonal in plan or any shap like Tee/L etc.
Providing and laying plan/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Foundation, footing, columns with base tie and plinth beam, pile cap, baseslab, retaining walls, wall of septic tank, inspection pit and the like and other works not less than 100mm thick up to a) M15 grade concrete or Prop 1:2:4
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junction with floor. (b) 20mm thick
Providing precast R.C.C. slab over drain, septic tank etc. in prop 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering, curing etc. complete including fixing in position as directed. b) 75 mm thick slab
Supplying, fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamp etc. as necessary complete at all levels including below G.L. as directed and specified. (iv) 75mm dia.
Providing fitting and fixing 50mm dia. HCL cowel with cement caulking complete as directed and
Providing fitting and fixing 450mm dia 90mm thick C.I. man hole cover and frame of 38kg weight complete as dirceted and specified
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.c. plain sheet above brick bat filling complete as directed (sizes of soak pit may vary depending on the sizes and capacities of
F) Construction of Deep Tube Well: Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, toolsn and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. ii) Bore hole of 100mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the barehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annual space between the borehole and assembly pipes complete. (a) TATA / SAIL (Medium) socket should be welded to the pipes. iii) 80 mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in A) G.I. pipe a) TATA / SAIL (Medium) socket should be welded to the pipes. iii) 40 mm diameter
Supplying fitting and fixing GI filter 2.00 metre long
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Supplying fitting and fixing Hand pump for 40mm dia tube well with all accessories complete as directed. (ii) Mayur
Supplying fitting and fixing check valve (non return valve) including thread to pipes. (iii) 40mm diameter
G) Internal & External Electrification: Wiring for light/fan/call bell point with 2×1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR Kabel / Nicco / Anchor orequivalent Make as approved by the Deptt.) in surface / recessed conduit wiring system with 20mm dia 2mm thick /heavy rigid PVC IS: 9537 part - III conduit (Berlia/ AKG/ Precision/ Presto plast/ Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta / Gold medal / Kolor Kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose (Anchor penta/ Gold medal/ Kolor Kany.Kom/ Havells or equivalent make as approved by the deptt.) etc. complete Short point up to 3.00 metre. Length.
Wiring for light/fan/call bell point with 2×1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR Kabel / Nicco / Anchor orequivalent Make as approved by the Deptt.) in surface / recessed conduit wiring system with 20mm dia 2mm thick /heavy rigid PVC IS: 9537 part - III conduit (Berlia/ AKG/ Precision/ Presto plast/ Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta / Gold medal / Kolor Kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose (Anchor penta/ Gold medal/ Kolor Kany.Kom/ Havells or equivalent make as approved by the deptt.) etc. complete Medium point up to 6.00 metre. Length
Wiring for light/fan/call bell point with 2×1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR Kabel / Nicco / Anchor orequivalent Make as approved by the Deptt.) in surface / recessed conduit wiring system with 20mm dia 2mm thick /heavy rigid PVC IS: 9537 part - III conduit (Berlia/ AKG/ Precision/ Presto plast/ Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta / Gold medal / Kolor Kany.Kom/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose (Anchor penta/ Gold medal/ Kolor Kany.Kom/ Havells or equivalent make as approved by the deptt.) etc. complete Long point up to 10.00 metre. Length.
Writing for 5/6 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 voits (Finolex / RR Kabel / Nicco / Ancchor or equivalent make as approved by the Deptt.) in surface / recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlet and 16 Amps flush type switch (Anchor penta / Gold medal / Kolor kany.kom / havells or equivalent make as approved by the Deptt.), GI/MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia / AKG / Precision / Presto Plast / Polycab / MW or equivalent make as appproved by the Deptt.) 3. Long point up to 10.00 meter. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multi strand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR Kabel / Nicco / Anchor or equivalent make as approved by the Deptt.) PVC conduit (Berlia / AKG / Precision / Presto Plast / Polycab / MW or equivalent make as approved by the Deptt.) including earth continuity in surface / recessed 20 mm dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 × 2.5 sq. mm. + earth continuity with 1 × 1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multi strand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR Kabel / Nicco / Anchor or equivalent make as approved by the Deptt.) PVC conduit (Berlia / AKG / Precision / Presto Plast / Polycab / MW or equivalent make as approved by the Deptt.) including earth continuity in surface / recessed 20 mm dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 × 4 sq. mm. + earth continuity with 1×1.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multi strand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex / RR Kabel / Nicco / Anchor or equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG/ Precision/ Presto Plast/ Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 3 × 6 sq. mm. + earth continuity with 2 × 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/ RR Kabel/ Nicco/ Anchor or equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta / Gold medal / Kolor Kany.Kom / Havells or equivalent make as approved by the Deptt.) make) and 6 amp flush type switch (Anchor penta/ Gold medal / Kolor Kany.Kom / Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Supplying and fixing of batten holder (Anchor Penta PC CHERRY / Gold medal / Kolor kany.kom / Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.) as required Without Lamp
Supplying and fixing of bulk head fitting suitable foe CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the deptt.) as required.
Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/ angle holder/ decorative bracket/ bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
Supplying and fixing of call bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt.) as required.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the Deptt. 12 way SPN single door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by deptt. 4 way TPN (4+12) Single Door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series 6 to 32A
Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (lcs=lcu, adjustable lr setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved by the Deptt.), as specified and directed by the deptt. 25KA 415v 50 Hz 3P MCCB (Havells, HPL, Indo Asian make) 63A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (lcs=lcu, adjustable lr setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved by the Deptt.), as specified and directed by the deptt. 25KA 415v 50 Hz 3P MCCB (Havells, HPL, Indo Asian make) 100A
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.i. pipe with necessary 40 mm dia. G.I. Fitting such as Socket, Tee, elbow, nipple and 50 mm × 40 mm G.i. reducing socket for funnel including locking arrangement 300 mm × 300 mm × 6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directedthe deptt.
Extra for using salt (5 k and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deppt.
Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L.) to electrical switch gear or electrical machineries including making necessary connection as approved, specified and directed by Deptt.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department [Without regulator]. Premium model 1400 mm sweep. (ORIENT PSPO)/Premium model 1400 mm sweep SS-390 deco. Havells make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. High Speed 225 mm sweep (ORIENT make), Trans Air 225 mm sweep (Crompton make), ventil Air DX 250 mm sweep Louver type (Havells make)
Supplying fitting and fixing of ceiling fan regulator including connection etc. complete as required. Electronic type
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cable up to 2×10 sq mm. 3×10 sq mm, 4×6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench ep to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco / Havells / RPG / CCI / Polycab / Gloster / Finolex make). 3 & 1/2 Core A2XFY 25.00 Sq. mm. 3 & 1/2 Core armoured cable (For service line)
Supplying including installation, connection as approved by the Deptt., testing and commissioning of OPENWELL SUBMERSIBLE PIMP SET complete with submersible cable etc. as directed and specified by the deptt. 1.5 HP Single Phase Open well Submersible monoblock water cooled pump set (Crompton Greaves / Aquatic / CRI / V- Guard make). 220V 50Hz, 2900 rpm with control panel.
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-dee / V GUARD / VERTEX / INDO / VENUS make) 5.0 KVA Automatic Input 90-280 v out put 200-240 v
Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.) up to 5m between the room unit and out door unit as directed by the department. 1.5 ton Capacity Voltas make
EXTERNAL ELECTRIFICATION Supply, installation & testing of Copper Plat earth station with 600 mm × 600 mm × 3 mm copper earth plate with necessary 40 mm dia G.I. medium duty watering pipe with G.I. Fitting such as Socket, Tee, elbow, nipple and 50 mm × 40 mm G.I. reducing socket for funnel including locking arrangement with 300 mm × 300 mm × 6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt. (For main building)
Extra for using salt (5 k and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt.
Supplying & laying of 8 SWG Copper. Earth from Earth Electrode (below G.L.) to electrical switch gear or electrical machineries including making necessary connection as approved, specified and directed by Deptt.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply autoroty for supervision charge, labour charge, cost of L.T/H.t metering etc. (excluding the cost of load security) and making necessary arrangement for charging approved of the sub-station from the complete authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200 KVA as per CEA guidline for losses along with LV anclosure. 25 KVA, 50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying and erection of H.T. stay set complete (Galvanize with 19mm dia × 1.8 m long stay rod anchor plate of size 30cm × 30cm × 6.4 mm thimble stay clamps tube buckle (19mm × 60c 7/3.15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6:( 1 Cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 75 mm × 40 mm × 65 × 2200 mm long complete with clamps, blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised Angle of 50 mm × 50 mm × 60 × 5000 mm long complete with clamps, blots, nuts etc. as required and as directed by the department.
Supplying and fitting, fixing of 11 KV T Cross arm somplete with clamps, blots, nuts etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I. pin, blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) 45KN with hard ware fitting etc. as required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department
Supplying and fixing of 11 KV 150 A.D.O. fuse set complete as required and as directed by the department.
Supplying and fixing of 11 KV 5KA Lightning arrestor (Poly) set complete as required and as directed by the department.
Supplying and string up AAAC Racoon conductor in the existing P.S.C./M.s. Galvanized pole with binding etc. as required and as directed by the department. Directed by the department
Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3(three section having a base plate including providing all required building materials as directed and specified by the deptt. ( BANSAL / SRP / Valmount / PARUTHI ENGR make) 410 SP 13, Length of pole=9.00 metre., Length of sections, Bottom= 4.50 M, Middle= 1.75M, Top = 1.75 M, Out side dia. & thickness Bottom= 138.70 × 4.50 mm, Middle = 114.30 × 3.65 mm, Top = 88.90 × 3.25 mm
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable lr setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 3P MCCB (C&S , Havells, Indo Asian, HPL, V-Guard oe equivalent make as approved by the Deptt.) 40A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable lr setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. (C&S , Havells, Indo Asian, HPL, V-Guard oe equivalent make as approved by the Deptt.) 125A
Payment to be made to APDCL authority For load security. (Rate as per APDCL)
3 Phase energy meter (Rate as per APDCL)
UTTAM SAHA
Amrita Paul
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .