Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC L1 is accepted | |
| 2 | L2₹47.9 L+₹1.3 L (2.74%)Rejected-AOC | L2 | Rejected-AOC L1 is accepted | |
| 3 | L3₹48.0 L+₹1.4 L (3.02%)Rejected-AOC | L3 | Rejected-AOC L1 is accepted | |
| 4 | L4₹48.8 L+₹2.2 L (4.63%)Rejected-AOC ASHIRBAD APARTMENT GANDHI S HOUSE RAMKRISHNA ROAD ASHRAMPARA SILIGURI 01 | L4 | Rejected-AOC L1 is accepted | |
| 5 | L5₹49.2 L+₹2.6 L (5.50%)Rejected-AOC | L5 | Rejected-AOC L1 is accepted |
| Sl No | Description | Qty | Unit | GEETA CONSTRUCTION L3 | KAMLESH ENTERPRISE L8 | S K ENTERPRISES L1 | R N De L4 | PRASAD PRADHAN AND SON L6 | MS MAYA PRAKASH GOEL AND SONS L5 | SUNIL PRADHAN L2 | MS BRAHMA CONSTRUCTION L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for disconnection of off road existing security light fitting of any type by isolating jumper from OH line, terminal connection from junction box and removing carbonised/defective part of the cable including replacement of unserviceable cable connection and reconnecting the same after making security light in ON road position, complete all as specified and as directed.
Note : New cable connection will be measured and paid separately under respective item. | 180 | Each job | 360 ₹64,800 | 370 ₹66,600 | 340 ₹61,200 Lowest | 370 ₹66,600 | 340 ₹61,200 Lowest | 370 ₹66,600 | 345 ₹62,100 | 360 ₹64,800 |
| 2.00 | Supply and fix in replacement of Street light driver of 40 watts, 230 V, 50 HZ, suitable for operation over voltage range and by removing from existing position as per existing make and model, complete all as specified and as directed.
Make-Crompton/Philips/Surya/Havells
Note : i) T&P required for carry out the repair work on street lights at a height up to 15 meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix casing of LED fitting. iii) Before quoting the rate of driver contractor should check the technical specification of the driver. | 10 | Each | 1,200 ₹12,000 | 330 ₹3,300 | 1,150 ₹11,500 | 1,235 ₹12,350 | 1,315 ₹13,150 | 1,250 ₹12,500 | 1,170 ₹11,700 | 320 ₹3,200 Lowest |
| 3.00 | All as per item No 2 above but cap. of 45 Watt LED fitting, complete all as specified and as directed. | 6 | Each | 1,250 ₹7,500 | 1,325 ₹7,950 | 1,200 ₹7,200 Lowest | 1,275 ₹7,650 | 1,310 ₹7,860 | 1,275 ₹7,650 | 1,230 ₹7,380 | 1,315 ₹7,890 |
| 4.00 | All as per item No 2 above but cap. of 50 Watt LED fitting, complete all as specified and as directed. | 8 | Each | 1,550 ₹12,400 | 1,660 ₹13,280 | 1,500 ₹12,000 Lowest | 1,570 ₹12,560 | 1,640 ₹13,120 | 1,600 ₹12,800 | 1,540 ₹12,320 | 1,650 ₹13,200 |
| 5.00 | All as per item No 2 above but cap. of 60/70 Watt LED fitting, complete all as specified and as directed. | 40 | Each | 2,300 ₹92,000 | 2,325 ₹93,000 | 2,250 ₹90,000 Lowest | 2,360 ₹94,400 | 2,255 ₹90,200 | 2,320 ₹92,800 | 2,270 ₹90,800 | 2,315 ₹92,600 |
| 6.00 | All as per item No 2 above but cap. of 90/120/110 Watt LED fitting, complete all as specified and as directed. | 12 | Each | 1,750 ₹21,000 | 1,920 ₹23,040 | 1,700 ₹20,400 Lowest | 1,790 ₹21,480 | 1,900 ₹22,800 | 1,800 ₹21,600 | 1,730 ₹20,760 | 1,910 ₹22,920 |
| 7.00 | All as per item No 2 above but cap. of 35 Watt Post top LED fitting, complete all as specified and as directed. | 6 | Each | 1,850 ₹11,100 | 2,110 ₹12,660 | 1,800 ₹10,800 Lowest | 1,880 ₹11,280 | 2,050 ₹12,300 | 1,900 ₹11,400 | 1,840 ₹11,040 | 2,100 ₹12,600 |
| 8.00 | All as per item No 2 above but cap. of 8 Watt BAMBOO bollard light LED fitting, complete all as specified and as directed. | 6 | Each | 1,300 ₹7,800 | 1,810 ₹10,860 | 1,240 ₹7,440 Lowest | 1,370 ₹8,220 | 1,600 ₹9,600 | 1,400 ₹8,400 | 1,260 ₹7,560 | 1,800 ₹10,800 |
| 9.00 | All as per item no 2 above but cap of 15 Watt post top , LED fitting, complete all as specified and as directed. | 6 | Each | 1,300 ₹7,800 | 1,810 ₹10,860 | 1,240 ₹7,440 Lowest | 1,370 ₹8,220 | 1,600 ₹9,600 | 1,400 ₹8,400 | 1,260 ₹7,560 | 1,800 ₹10,800 |
| 10.00 | Supply and fix in replacement of surge protector of 5 KV suitable to accomadate in LED street/flood light fittings of 25 watts to 200 Watts, 230 V, 50 HZ by removing from existing position, complete all as specified and as directed.
Note : i) T&P required for carry out the repair work on street lights at a height up to 15 meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix inside casing of LED fitting. | 25 | Each | 900 ₹22,500 | 1,460 ₹36,500 | 800 ₹20,000 Lowest | 960 ₹24,000 | 1,250 ₹31,250 | 1,100 ₹27,500 | 850 ₹21,250 | 1,450 ₹36,250 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
28 Jun 2025, 6:00 pmClosed
Garrision Engineer GE 867 EWS
GE 867 EWS C/O 99 APO
REPAIR MAINT OF SECURITY/STREET LIGHT FLOOD LIGHT HIGH MAST LIGHT POST TOP LANTERN, GATE LIGHT AUTOMATIC TIMER SWITCH POLE PAINTING AND REPAIR REPLACEMENT MAINT OF LT DISTRIBUTION OH LINE UG CABLE MCCBs SERVO VOLTAGE STABBLIZER AND CONNECTED M
2025_MES_713068_1
8510/E8
Open Tender
Civil Works
Item Rate
180 days
Kalimpong
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 867 EWS
₹86,000
14 Sept 2025
7 Jun 2025
5 Jul 2025
7 Jun 2025
28 Jun 2025
21 Jun 2025
Amount
Labour only for disconnection of off road existing security light fitting of any type by isolating jumper from OH line, terminal connection from junction box and removing carbonised/defective part of the cable including replacement of unserviceable cable connection and reconnecting the same after making security light in ON road position, complete all as specified and as directed. Note : New cable connection will be measured and paid separately under respective item.
Supply and fix in replacement of Street light driver of 40 watts, 230 V, 50 HZ, suitable for operation over voltage range and by removing from existing position as per existing make and model, complete all as specified and as directed. Make-Crompton/Philips/Surya/Havells Note : i) T&P required for carry out the repair work on street lights at a height up to 15 meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix casing of LED fitting. iii) Before quoting the rate of driver contractor should check the technical specification of the driver.
All as per item No 2 above but cap. of 45 Watt LED fitting, complete all as specified and as directed.
All as per item No 2 above but cap. of 50 Watt LED fitting, complete all as specified and as directed.
All as per item No 2 above but cap. of 60/70 Watt LED fitting, complete all as specified and as directed.
All as per item No 2 above but cap. of 90/120/110 Watt LED fitting, complete all as specified and as directed.
All as per item No 2 above but cap. of 35 Watt Post top LED fitting, complete all as specified and as directed.
All as per item No 2 above but cap. of 8 Watt BAMBOO bollard light LED fitting, complete all as specified and as directed.
All as per item no 2 above but cap of 15 Watt post top , LED fitting, complete all as specified and as directed.
Supply and fix in replacement of surge protector of 5 KV suitable to accomadate in LED street/flood light fittings of 25 watts to 200 Watts, 230 V, 50 HZ by removing from existing position, complete all as specified and as directed. Note : i) T&P required for carry out the repair work on street lights at a height up to 15 meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix inside casing of LED fitting.
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed.
Supply and fixing in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and as directed.
Supply and fixing in replacement post-top-luminaire, 15 watt, IP-65 protoection, operating temp -10 degree celcius to +45 degree celcius, Operating voltage range - 140-270 V, Die-cast aluminium spigot housing for mouting of driver with spun aluminium canopy Mounting suitable for pole having 50 to 70 mm, complete all as specified and as directed. Make : Havells, cat part No RUBYMINIPT15WLED757PSYMTOPC, Model : RUBY (Clear) or equivalent.
S&F in repalcement of Cone shaped LED Bollard light fittings, 10 watt, IP 65, diffuser at the upper portion, 0.5 mtr long including fixing arrangemets and eletric connection, complete all as specified and as directed. Make- Crompton Cat pt No- LBLSn-10-CDL OR equivalant from CG/ Philips/ Bajaj
M & L for replacing power contactor Three pole with coil voltage 230 volt of capacity 40 Amps 50 cycles, complete all as specified and as directed. Make Legrand / Standard / L&T MNX40
M&L for replacing Light sensor automatic nature switch (sensor) illuminance level for switching ON 60 Lux, complete all as specified and as directed. Make Healer Enterprises Or equivalent
S&F in replacement of TPN MCB 63 Amps rating, 'C' curve and having breaking capacity 10 KA including taking out of old u/s MCB, complete all as specified and as directed.
Supply and fixing in replacement of Thermal magnetic release MCCB 4 pole 415 volt rapturing capacity 16 KA 0f size 100 amp complete all as specified
Supply and fixing in replacement of Thermal magnetic release MCCB 4 pole 415 volt rapturing capacity 36 KA 0f size 160 amp, complete all as specified and as directed.
S&F street light bracket made out of GI tubing 40mm bore, medium grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of MS Flat with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete including taking down u/s bracket any type, complete all as specified and as directed.
Trimming of tree branches which touches the LT/HT OH lines and 2.5 Mtr away from centre line of LT/HT oh lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site Note -Any number of tree branches cut in one span will be measured as one lenght of payment ,
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation,trenches, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but n exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m in depth but n exc 3 m in depth and getting out in soft/loose soil, complete all as specified and as directed.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm, complete all as specified and as directed.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point, complete all as specified and as directed.
M&L for providing dry river sand as in sand cushioning to under ground cable including punning down of sand in layers, complete all as specified and as directed.
Supplying and laying Bricks common burnt clay building bricks, sub-class ‘B’ for cable protection, complete all as specified and as directed.
Supply & Laying in replacement of GI pipe light grade as protection for UG cable/for stand of post top lantern complete all as specified & directed of size of bore dia 40mm , complete all as specified and as directed.
Supply & Laying in replacement of GI pipe light grade as protection for UG cable/for stand of post top lantern complete all as specified & directed of size of bore dia 50mm, complete all as specified and as directed.
M&L for taking out old unserviceable UG cable of any size/ type from trenches/ wall/ roof etc. for necessary repair/ replacement/ re-laying works, complete all as specified and as directed. Note :- 1. Excavation and earth work should be measured and paid separately.
Supply,laying,jointing and testing, fixing to wall /pole/floor using clamps or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 volts grade with multistranded aluminium conductor of size 150 sqmm 3.5 core ISI marked ( IS - 7098 Part-1) and its latest amendments, complete all as specified and as directed.
Supply,laying,jointing and testing, fixing to wall /pole/floor using clamps or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 volts grade with multistranded aluminium conductor of size 50 sqmm 3.5 core ISI marked ( IS - 7098 Part-1) and its latest amendments, complete all as specified and as directed.
Supply,laying,jointing and testing, fixing to wall /pole/floor using clamps or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 volts grade with multistranded aluminium conductor of size 35 sqmm 3.5 core ISI marked ( IS - 7098 Part-1) and its latest amendments, complete all as specified and as directed.
Supply,laying,jointing and testing, fixing to wall /pole/floor using clamps or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 volts grade with multistranded aluminium conductor of size 25 sqmm 4 core ISI marked ( IS - 7098 Part-1) and its latest amendments, complete all as specified and as directed.
Supply,laying,jointing and testing, fixing to wall /pole/floor using clamps or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 volts grade with multistranded aluminium conductor of size 16 sqmm 4 core ISI marked ( IS - 7098 Part-1) and its latest amendments, complete all as specified and as directed.
Supply,laying,jointing and testing, fixing to wall /pole/floor using clamps or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 volts grade with multistranded aluminium conductor of size 10 sqmm 4 core ISI marked ( IS - 7098 Part-1) and its latest amendments, complete all as specified and as directed.
Supply,laying,jointing and testing, fixing to wall /pole/floor using clamps or in air or passing through pipes /ducts / road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 volts grade with multistranded aluminium conductor of size 10 sqmm 2 core ISI marked ( IS - 7098 Part-1) and its latest amendments, complete all as specified and as directed.
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe, complete all as specified and as directed.
Laying only LT under ground cable PVC/XPLE insulated PVC sheathed 1100 V grade armoured/ unarmered any type including testing commissioning of the cross sectional area 6 mm² to 150 Sq mm², 2/ 3.5/4 core, complete all as specified and as directed. Note :- Cable will be issued under Sch 'B' free for fixing. Excavation and earthwork will be measured under respective items.
Taking out and relaying of existing brick/cable cover to the existing trench after completion of fault finding work of cable, complete all as specified and as directed. Note :- Excavation work will be paid under respected item.
Material and labour for taking out and relaying of existing cable of any size after completion of fault finding work of exiting cable, complete all as specified and as directed. Note :- Cost of excavation of cable will be paid respective item.
Dismantling unserviceable steel poles of any size including demolition of foundation concrete & removing from site, complete all as specified and as directed.
Supply and errect for steel tubular swaged Poles Type 410-SP-31 (9 Metre long) conforming to IS 2713 including cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of RCC copping) including writing MES Pole No. with synthetic enamel paint (first grade quality), complete all as specified and as directed. Note:- (a) Earthwork and PCC will be measured and paid separately (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
M&L for painting of 9 Mtr Long steel tubular LT pole , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles, cross arms, painting 30 cm wide Yellow and black strip on poles up to 1.5 mtr high above coping level and numbering of size 70mmx40mm by using stencil to the pole with black synthetic enemal paint (1st grade ), complete all as specified and as directed.
M & L for Plain Cement Concrete (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation, filling and mass-concrete etc for pole, stay etc, complete all as specified and as directed.
M & L for Plain Cement Concrete (1:3:6) type C-1 using 20 mm graded stone aggregae as in copping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra, complete all as specified and as directed.
Supply & fixing in replacement automatic street light switch of rating 8 KW in single phase using nature sensor for automatic swithing "ON/OFF" of street lighting based on lux level of natural light along with 63 Amps contactor, MCB 63 Amps with support terminals prewired with PVC insulated 16 Sqmm multi strand copper wire enlosed/housed in pole wall mounted enclosure made of rust proof , shock proof , termite proof & dust proof FR grade moulded compound Junction Box, complete all as specified and as directed. Model - SWADEEP - 02EC 8 KW 1 P MAKE- 1.Nature-Nature Switch : Kakatiya Energy systems Pvt. Ltd / HEALER / BAJAJ
Supply & fixing in replacement automatic street light switch of rating 8 KW in Three phase using nature sensor for automatic swithing "ON/OFF" of street lighting based on lux level of natural light along with 63 Amps contactor, MCB 63 Amps with support terminals prewired with PVC insulated 16 Sqmm multi strand copper wire enlosed/housed in pole wall mounted enclosure made of rust proof , shock proof , termite proof & dust proof FR grade moulded compound Junction Box, complete all as specified and as directed. Model - SWADEEP - 02EC 8 KW 3 P MAKE- 1.Nature-Nature Switch : Kakatiya Energy systems Pvt. Ltd / HEALER / BAJAJ
M&L for junction box hot press moulded SMC of size 295 x 195 x 100mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having TPN Bus bar 100A amps including MCB SP 2 Amps Breaking Capacity 10 Ka C Curve capacity with necessary base insulator and including necessary flat iron clamps with nuts, bolts & washers, complete all as specified and as directed.
M & L for junction box hot press moulded SMC of size 155 x 155 x 100mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having TPN Bus bar 100A amps including MCB SP 2 Amps Breaking Capacity 10 Ka C Curve capacity with necessary base insulator and including necessary flat iron clamps with nuts, bolts & washers, complete all as specified and as directed.
M& L for connection of junction box to street light luminaire using wiring with two runs (P-N) of single core 1.5 sqmm (nominal area) FR PVC insulated and sheathed 3 core copper conductor cable 1100 volts grade through PVC conduit (heavy grade ) and tiding the same by aluminium strip with the pole, complete all as specified and as directed.
M&L in replacement of Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron wire 4mm dia by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, complete all as specified and as directed.
Supply & Fix in replacement 3 Core copper cable 1100 volts grade PVC insulated and PVC sheathed of size 1.5 sqmm, complete all as specified and as directed.
PVC flat twin core unarmoured Aluminium cable of size 4.0 Sqmm, complete all as specified and as directed.
PVC flat twin core unarmoured Aluminium cable of size 6.0 Sqmm, complete all as specified and as directed.
PVC flat twin core unarmoured Aluminium cable of size 10 Sqmm, complete all as specified and as directed.
M&L for Painting of complete GI post top light fitting pipe hight upto 1 mtr with PCC protection of pipe by applying single coat of synthetic enamel paint after preparation of existing surface of GI post, colour as existing, complete all as specified and as directed.
Supply and lay DWC HDPE pipe 50 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection, complete all as specified and as directed. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of inner dia 75 mm including all fittings complete all as specified and directed.
Supply and lay DWC HDPE pipe 40 mm bore medium class, ISI Marked double wall corrugated for open/underground laying cable, cut to size and making the tubing for cable protection, complete all as specified and as directed. Note (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates. as in cable protection pipe of inner dia 75 mm including all fittings complete all as specified and directed.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, M&L, complete all as specified and as directed.
Dismantling and taking out old cement concrete in foundation/ floor of any type, complete all as specified and as directed.
Dismantling unserviceable cross arms, clamps etc, complete all as specified and as directed.
Supply and fixing cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including a coat of red oxide primer one underand & one finishing coat, complete all as specified and as directed.
M & L for Cutting the faulty/damaged/burnt end portion of the UG cables of crossectional area 16sqmm to 35 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing its own position, including Insulation tape, nut ,bolts etc as required in distribution boards/LT Panel boards/Change over switches, complete all as specified and as directed.
M & L for Cutting the faulty/damaged/burnt end portion of the UG cables of crossectional area 50 sqmm 3.5 core and making good end termination with and including suitable size of aluminium thimble/lugs duly crimped with crimping tool and refixing its own position, including Insulation tape, nut ,bolts etc as required in distribution boards/LT Panel boards/Change over switches, complete all as specified and as directed.
M&L for jointing heat shrinkable after removing faulty cable, straight joints for PVC armoured heavy duty underground cable including joint kits complete for making joints suitable for aluminium Conductor cable 25 to 50 sqmm 3½ core 1100 volts grade and necessary testing after jointing, complete all as specified and as directed. Note : For item above rate for necessary excavation is inclulded in the quoted rate, excavation beyond 6 mtr will be paid under relevant items.
Repairs/Maint of LT Panel board/box of various sizes including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size,replacing burnt DMC insulator or bus bar supports as per exsiting one, removing old burn out wiring and re-wiring with new cable of exsiting size, including replacement of un-serviceable parts, complete all as specified and as directed. Note :- (i)New spares required shall be measured and paid separately under relevants items . (ii) cost of unsheathed multistranded copper conductor of size upto 2.5sqmm for internal wiring like connection of CTs and DMC insulators are deemed to be included in quoted rate. (iii) For item No. 70 to 74 fixing charge of items are considered in item no. 69. (iv) All calibration of meters to be done by contractor after fixing in position. (v)Suitable size of copper cable lugs to be provided by contractor for for fixing /jointing the cable in bus bar etc.
Supply only 3 phase single function LED Voltmeter flush mounting 96X96mm of input voltage measurement range 50-520 VAC(P-P) , 5A,accuracy class 1 for LT panel board, complete all as specified and as directed. Make : L&T Cat part no. WL132010OOOO or equivalent in conserv/siemens
Supply only 3 phase VAF+ PF digital meter flush mounting 96X96mm of input voltage measurement range 50-520 VAC(P-P) , 5A,accuracy class1 for LT panel board, complete all as specified and as directed. Make : L&T Cat part no. WL411021OOOO or equivalent in conserv/siemens
Supply only 3 phase Energy digital meter flush mounting 96X96mm of input voltage measurement range 50-520 VAC (P_P) , 5A,accuracy class1 for LT panel board, complete all as specified and as directed. Make : L&T Cat part no. WL4000010OOOO or equivalent in conserv/siemens
Supply only Indoor tape insulated ring type low tension current transformers of ratio 500/5A accuracy class 1.0 for LT panel board, complete all as specified and as directed.
Supply only LED Indicator lamps to be mounted on LT panel for R,Y,B phase (of colour Red,green,yellow) operates on 240V AC for fixing in the existing place in LT panel board, complete all as specified and as directed.
M & L for Prunning / trimming the branches of trees if any along overhead line, 1 m on all side below/ above/ sides of overhead line and removing the same upto 150 m away each span not exceeding 45 m, complete all as specified and as directed.
S&F MCCB with Thermal - magnetic release of 80-100 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable one, complete all as specified and as directed.
S&F MCCB with Thermal - magnetic release of 160-200 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable one, complete all as specified and as directed.
S&F MCCB with Thermal - magnetic release of 200-250 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable one, complete all as specified and as directed.
S&F MCCB with Thermal - magnetic release of 320-400 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable one, complete all as specified and as directed.
M&L for Stringing /stretching, including jointing in situ of each span not more than 45 m between two electric poles having 4 Nos of ACSR of any size including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing, complete all as specified and as directed.
M&L for Stringing /stretching, including jointing in situ of each span not more than 45 m between two electric poles having 2 Nos of ACSR of any size including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing, complete all as specified and as directed.
Dismantling unserviceable/old ACSR conductors of any size from over head lines, poles by removing binding wire, service wire, cables and removal from site, complete all as specified and as directed.
M&L for ACSR conductors (weasel type) for LT OH lines on poles including stringing, binding with aluminium wire 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection, complete all as specified and as directed.
Taking down old unsv/ corroded LT feeder pillar box/ DB Box/ Busbar Chamber of any sizes or types (after disconnection of all electrical connections) complete for replacement with new one, complete all as specified and as directed.
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof busbar feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40mm x 40mm x 6mm , powder coated over one coat of red oxide primer, factory made duly fixed on the ground by PCC foundation (1:2:4) Type B-1 of size 300mm x300mm x600mm on the adjacent pairs of leg & net cementing the same.The feeder pillar box painted with two coats of epoxy based powder coated over a coat of red oxide primer (internally & externally) on the surface, complete all as specified and as directed. The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty industrial door hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements. The box should have provision/accommodation of the following electrical items INCOMING: (i) Rectangular Aluminium bus bar fixed on insulated mounting arrangement of rating 1.5 times current carrying capacity of incoming switch gear or not less than 200 Amp whichever higher provided with heat shrinkable sleeve not less than one mm thick. -04 Nos (ii) Indicator lamp for RYB phase (iii)Moulded case circuit breaker 80-100 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 Nos. Make : L & T Cat Part No. CM91712OOKOOG or equivalent in Schneider/ ABB.
M&L for earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc, complete all as specified and as directed.(set of two) NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Supply and fix in repair Onload change over switch conforms to S/IEC 60947-3 of current rating 200Amps ,4 P ,415 Volt with steel sheet enclosuresuitable for horizontal as well vertical mounting, complete all as specified and as directed. Make : L&T Cat Part No. CO10630OSOO or equivalent in Hapells/C&S
S&F in repairs 1100 volts grade heavy duty flat cable of size 10Sqmm 2 core, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections supported by 4mm suspension wire, complete all as specified and as directed.
M&L for complete removal of existing treatment of LT Panel, box, board, etc and applying two coats synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
Note : In case of doubling/duplicancy of BOQ items, the lowest quoted rate shall be applicable for payment.
SUNIL PRADHAN (BID ID -3339303)
GEETA CONSTRUCTION (BID ID -3334831)
R N De (BID ID -3338949)
MS MAYA PRAKASH GOEL AND SONS (BID ID -3339284)
PRASAD PRADHAN AND SON (BID ID -3339260)
MS BRAHMA CONSTRUCTION (BID ID -3339254)
KAMLESH ENTERPRISE (BID ID -3336538)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .