Loading…
Loading…
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
27 Nov 2024, 3:00 pmClosed
COMMISSIONER
AVADI CITY MUNICIPAL CORPORATION AVADI CHENNAI 54
Renovation work of laying tiles, weathering course, interior works, furniture arrangements and other works at Zonal Office Buiding in Ward No.27
2024_MAWS_504486_1
ROC No 9915/2024/E1-16
Open Tender
Civil Works
Fixed-rate
60 days
WARD NO 27
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹15,000
27 Dec 2024
25 Nov 2024
27 Nov 2024
25 Nov 2024
27 Nov 2024
25 Nov 2024
Amount
Supply and delivery of OFFICE CHAIR with Deluxe Mesh chair with folding Arms, Breathable Mesh Back, Air Flow Mesh Seat, Tilt Mechanism lockable in the upright position, Folding Arms, Heavy duty gas lift (110 kilos), Foam and Fabric conform to BS5852 UK FR, W690 x D755 x H960 - 1060mm etc., complete
Supply and delivery of COMPUTER CHAIR with Low back chair with arms and plastic outer cover, Primary Material – Castors, Chair base, Gas lifter, chair arm, Press wood sheet, Plastic outer cover, Style – Modern, Finish – Fabric etc., complete
Supply and delivery of plastic chair with approved quality and colour and cost and conveyance of material to site, etc, complete
Supplying and fixing of System table with Key Board Rack to site, by using of MDF (Medium Density Fiber) panel sheets, the cost including of material charges, making charges ,Required hinges at bottom support, nails, screws for joints and labour complete. At computer Zone area tables based on number of computers.(Measurements for Computer tables, For each system cabin Length =0.90m,Width = 0.60m,Height of table top from ground = 0.76m,Cabin partition height from table top = 0.25m)
Supplying and fixing of Manager Room Table to site, by using of MDF (Medium Density Fiber) panel sheets system fittings and keyboard section with the over all table size of 2.20m x 1.10m with Height = 0.77m to site with required trays and Draws at both sides, the cost including of material charges, making charges and labour etc., complete.
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum.
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Supply, installation, testing, commissioning of 2.5 Ton Split type AC unit 5 star rated contained ductable ac including cost and coveyance of material and other charges etc complete.
Supply and fixing of Copper Refrigerant Piping of 7/8" dia pipe including cost and coveyance of material and other charges etc
Supply and filling of R-22 Refrigerant Gasr including cost and coveyance of material and other charges etc complete.
Supply and fixing of MS stand for fixing outdoor unit including cost and coveyance of material and other charges etc complete.
Supply and installation of 4 KVA capacity Automatic Voltage Stabilizer with time delay relay and including cost and coveyance of material and other charges etc complete.
supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 450mm (18")
supply and fixing of wall mounting fan with 300mm with fan clamp with side plates and cincluding cost and coveyance of material and other charges etc
Supply and installation of Anutone / Hera Design / Tectum / Equivalent Brand of Acoustical Fibre Based Wall Panelling of strand colour, kerfed edge magnesite bonded pine wood fibre core tiles of size 600 x 2400 x 20mm, density 400 kgs / m3, weight 8 kg / m2 installed by using GI strut frame work system with non-visible fasteners usin PVC strut H-Spline. The GI strut frame work systems includes GI strut CC 50 cross channel having thickness 0.7mm, length 3600mm, knurled web 50, depth 50mm and equal flanges 15mm is fastened to wall positioned horizontally in a regular manner at 600mm centre to centre. PVC strut H-Spline having sectional thickness 2mm and length 2400mm to be fixed perpendicular to the Strut CC50 cross channel at 600mm centers. The kerfed edge panels shall be then inserted into the strut H-Spline along their long edges of 2400mm against frame work to perfect fit with staggered short edges. The system is backlined with the acoustical infill Anutone or Equivalent Brand of SynthPF 500 gsm 50mm thick. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department officers. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc., complying to standard specication.
Supply,delivery and fixing of interior fall ceiling with gypsum colour coated including labour charges and all other incidental charges etc complete
Supply,delivery and fixing of floor carpet mat colour coated including labour charges and all other incidental charges etc complete
M Karthik (BID ID -1194363)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .