Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | ₹3.3 L | L1 | Accepted-AOC AOC Issued |
| 2 | L2₹3.8 LRejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹3.8 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹4.1 LRejected-Finance | ₹4.1 L | L3 | Rejected-Finance that the bid is not L1 |
| 4 | L4₹4.4 LRejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKATA 700158 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700158 | ₹4.4 L | L4 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | MILLENNIUM AIRCON L2 | ANIKET COOLING AND REFRIGERATION CO L4 | P. M. COOLING AND ENGINEERING CO L1 | M.S. COOLING & ENGINEERING CO. L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Annual Comprehensive maintenance Charge for 2.5TR Refrigeration Units of Walk in Cooler (5 Set) for blood bag
2.5 TR x 5 Set = Total 12.5 Ton | 5 | Set. | 4,444 ₹2.7 L | 5,100 ₹3.1 L | 3,800 ₹2.3 L | 4,850 ₹2.9 L |
| 1.10 | Annual Comprehensive maintenance Charge for 3TR Air Conditioning & Refrigeration Units of Walk in Cooler (2 set for blood bag )
3 TR x 2 Set = Total 6 Ton | 2 | Set. | 4,777 ₹1.1 L | 5,400 ₹1.3 L | 4,200 ₹1.0 L | 4,900 ₹1.2 L |
| 2.00SCOPE OF WORK 1.) Compulsory Preventive maintenance of every machine once in Two month. It includes, clearing of coils, air filters, Checking grill temperature & room temperature, current drawn, Condition of PCB,Condition & temperature of Capacitor , Drain line, Gas pressure, Cooling coil thermostat. 2.) Daily noting of the details of Preventive Maintenance Details in Maintenance register. Failing which a deduction of Rs. 1000/Month will be applicable from the bill. | |||||||
| 3.003.) The Contract covers free replacement of all spare parts including compressor (includes all type of AC Machine), capacitors, relays, thermostats, fan motors, Inside electrical wiring unit, indoor PCB, outdoor PCB, contactors, terminals,S2/P2 Type Capacitors and all others necessary parts which required at AC machine. In case of gas leakage in the system, Agency shall carry out leak test and rectify the same with gas charging. 4) Agency Should attend the Breakdown call within 1 hour. Failing which Rs. 500/machine/breakdown call will be deducted. | |||||||
| 4.005.) Incase of breakdown where replacement of spares are required, 24 hrs will be provided for spares except compressors and 72hrs will be provided only in case of compressors. 6.) Failing to meet the time line in case of breakdown where spares invlove Rs. 500/day/machine will be deducted. 7.)All the spare required to be replaced, should be of approved make. | |||||||
| 5.008.) Yearly Once complete servicing & Overhauling & oiling to be carried out of each unit after taking out from its position as per instruction of AE/JE. 9.)In case of break-down of A.C. machines, If the machine is required to be removed / shifted to Workshop hours, then a temporary AC machine of same capacity will have to install to cool the work place & no extra claim will be entertain for this temporary AC machine arrangement & dismantling. If loan machine is not provided timely by agency, a penal amount of Rs. 100/day will be deducted from the contractor’s bill till reinstallation of AC machine or as per the direction of EIC) | |||||||
| 6.0010.) The agency will have to depute minimum 1 Nos AC Technician With 1 helper for day shift & 1 Nos AC Technician for rest of the shifts including holidays under his direct supervision. 11.)Any damage of parts due to negligence of technician of agency (if detected), will liable for penalty. Penalty amount is the actual cost of the same parts. 12.)The contractor should have their office with Telephone number and Mobile number in Kolkata and the same should be intimated to this Department in writing, the telephone call should be responded without delay. | |||||||
| 7.0013)The agency should cautious maintan the walk in cooler Temperature 4 degree centigrade or as specified | |||||||
| 8.0014.)The agency should provide photo identity cards to all the maintenance staff employees including substitute’s employee(s) duly signed by concerned agency & JE. 15.Agency should provide sufficient Tools and Tackles for smooth maintenance work. Zet Pump should be available at site. 16.In case of any accident and/or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only. | |||||||
| 9.00(Rate should be quotated including all taxes and duties and GST) | |||||||
Tender Value
Refer Docs
EMD Value
₹8,200
Closing Date
26 Jun 2024, 1:00 pmClosed
EEI,KNHED, PW Dte
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
Annual Maintenance Servicing of Chiller units in walk-in coolers at I.B.T.M. I.H., Maniktala.
2024_WBPWD_692500_1
WBPWD/EE/KNHED/NIQ-16/2024-25
Open Tender
A/C ORG
365 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,200
Office of The EE, KNHED, PW Dte
16 Apr 2026
12 Jun 2024
28 Jun 2024
12 Jun 2024
26 Jun 2024
20 Jun 2024
19 Jun 2024
stage.html
html • 0.05 MB
technical_1508141.pdf
techsummary_1508141.pdf
finance_1508141.pdf
BOQ Comparative Chart
xlsx
finsummary_1508141.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.47 MB
2911_Form.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_1508141.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid