Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC HOSUE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | L1 | Accepted-AOC Tender AOC | |
| 2 | L2₹49.0 L+₹3.5 L (7.80%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹49.2 L+₹3.7 L (8.14%)Rejected-Finance 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹50.3 L+₹4.8 L (10.5%)Rejected-Finance H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹50.5 L+₹5.0 L (11.0%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L5 | Rejected-Finance Being L5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
2 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST HISAR
GE WEST HISAR HISAR MIL STN HISAR 125006
GE(W)/HSR-50/2021-22 REPAIR TO ROOF LEAKAGE IN JCOs/OR MD ACCN AREA AT HISAR MIL STN UNDER GE(W) HISAR
2022_MES_506646_1
GE(W)/HSR-50/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrrison Engineer (West) HISAR MILITARY STATION
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE WEST HISAR
₹98,000
Yes
8 Mar 2022
8 Feb 2022
4 Mar 2022
8 Feb 2022
2 Mar 2022
23 Feb 2022
60 days
Amount
Dismantling brick tiles in single layer on roof (laid dry and pointed) complete all as spd ad directed
Demolition Mud in roofs, any thickness,including plastering and leeping (whether full thickness removed or only a part thereof)and removing debries out of MD land as directed.
Demoliton of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing debries out of MD land as directed.
M&L Brick work with flyash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as spd and directed
Demoliton of cement concrete of any description & in any position not otherwise specifically provided for and removing debries out of MD land as directed.
M&L for providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof kerbs, Roof padding all as specified.
M&L Screed bed or bedding layer of mortar 10mm thick in cement mortar 1:3 and finishing even and smooth with mixing of liquid WPC on roof surfaces. Note : WPC shall be measured and paid seperately.
Supply only liquid water proofing compound complete all as spd and directed
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3mm thick) weighing not less than 3.50 Kg per Sqm, consisting of 90 micron center core laid by torch application method with overlap 100 on length and 100mm on the width side as per manufacture's instructions over a coat of hot air blown grade bitumen 85/25 @ 1.20Kg/Sqm over a coat of approved cold applied bituminous oil based primer (IS-3384) @ 300 gm/sqm complete and applying two coats of aluminium paint over APP membrane all as specified and directed.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including raking out joints, hacking for key scrubbing down with water etc and removal of rubbish out of the MD land all as specified and directed
M&L for rendering 15 mm thick in CM 1:4 on stone/brick/ concrete masonry surfaces with using integral water proofing compound finished even and smooth without using extra cement all as specified and directed
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted over a coat of primer on walls all as directed
Dismantling of old unservicable water tank of capacity 500 litre capacity and taking out MD land all as spd and directed
S&F in repair Rotational moulded polythylene water storage tank tripple layer in white colour of capacity 500 lts (Cylindrical, Vertical with closed top) in position with 20mm float ball in repairs complete all as specified and directed.
S&F in repair 15 mm dia Stop valves / gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixedcomplete all as specified and directed.
S&F in repair 20 mm dia Stop valves / gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixedcomplete all as specified and directed.
Disconnecting existing tanks Exc 500 & 1000 lit capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position.
Taking up or down steel tubing 15 mm dia including connections and fittings complete all as specified and directed.
S&F for galvanised steel tubing 15 mm dia (ISI) marked medium grade with necessary fittings lie tees, elbows, sockets, reducers, bends etc including necessary cutting, threading laid in trenches/floors, fixed to walls etc complete all as specified and directed
All as per above Ser No 19.00 but fixing only complete all as specified and directed
Taking up or down steel tubing 20 mm dia including connections and fittings complete all as specified and directed.
S&F steel water tubing galvanised 20mm bore, medium grade with all fittings fixed to wall and ceiling or in floor complete all as specified.
All as per above Ser No 22.00 but fixing only complete all as specified and directed
Taking down eaves gutter or RWP of any description complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps and complete all as spd and directed
S&F 110mm dia PVC bend any radius complete all as spd and directed
Demolition of RCC Roofs, floors (other than ground floors), beams, staircases, landing, chajjas upto three storeys ,RCC Water tanks and similar suspended work and making good the disturbed area in CM 1:3.
M&L for cutting holes in brick walls built in cement mortar /concrete for inserting support for chajjahs/ cooler plateforms / cooler standetc and making good dismantled portion in cement mortar 1:3 or PCC 1:2:4 type B1 as required super ficial area of cutting nexc 100sqcm complete all as spd and directed. Note:- cutting of holes shall be carried out by core cutting machine.
S&F prepainted galvalume alumimium zinc coating GI based plain steel sheet 0.50 mm thick of any color having tensile strength of 550 MPA as a roof covering /Cladding to wall and in Chajjah , Fixed with self tapping screw complete all as spd and directed
S&F mild steel joist ,channel ,angle ,tee fixed independently without connection plates etc (cut to ordinary length i.e. within 20mm of the length indicated ) complete all as spd and directed
M&L preparing new steel surfaces over 10 cm in width or girth of any description and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as spd and directed
SITA RAM AND SONS
VERMA BROTHERS
virendra constructions
M/s Devendera construction
fauji electric works
M/S Sulakh Brothers
HANS ENGINEERS
SHRI HARI BUILDERS
M/S RAJESH KUMAR & SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .