Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance B402 SOMDUTT CHAMBERS 1 SMS INDIA PRIVATE LIMITED 5 BHIKAJI CAMA PLACE NEW DELHI 110066 SOUTH WEST DELHI DELHI 110066 | NEW DELHI | DELHI | 110066 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹1.0 Cr
Closing Date
20 Jun 2022, 5:00 pmClosed
CE/PDC
Shakti Bhawan, Sector-6, Panchkula
Construction of 220 KV AIS substation Nain
2022_HBC_217378_1
EPC-D No. 49/PDC
Open Tender
Electrical Works
540 days
Panchkula
Please refer Tender documents.
7 documents required · 7 mandatory
₹11,800
₹1.0 Cr
Yes
24 Jan 2023
18 Apr 2022
30 Jun 2022
18 Apr 2022
20 Jun 2022
18 Apr 2022
a) 160 MVA 220/132 kV Power Transformer along with 10% extra T/F oil b) NIFPES for 160 MVA T/F
a) 100 MVA, 220/33 kV Power Transformer along with 10% extra T/F oil b) NIFPES for 100 MVA T/F
220 kV SF-6 Breaker along with 20% extra SF-6 Gas
220 kV Isolator with E/Switch
220kV Isolator without E/Switch
220 kV Surge Arrestor
220 kV Post Insulator
220 kV CTs for line & bus coupler (1200-800-400/1-1-1-1-1A)
220 kV CT for Transformer (450-300/0.577-1-1-1-1A)
220 kV CVT
220 kV C&R Panels a) Line Protection & Circuit Breaker control panel (with auto reclose)
b) Transformer protection & Ckt breaker control Panel (without auto reclose ) for HV side of 220/132kV T/F. (1 set for each T/F)
C) Transformer protection & Ckt breaker control Panel (without auto reclose ) for HV side of 220/33kV T/F.
d) Bus Coupler cum Bus Bar Protection & Ckt breaker control Panel without auto reclose (Double Bus bar)
220 kV NCT (450-300/1A)
132 kV SF-6 Breaker with 20% extra SF-6 Gas
132 kV Isolator with E/SWITCH
132 kV Isolator without E/SWITCH
132 kV Surge Arrestor
132 kV Post Insulator
132 kV CT For Line (600-300-150/1-1-1A)
132 kV CT For Bus Coupler (750-500/1-1A)
132 kV CT For Transformer I/C (750-500/0.577-1-1-1A)
132 kV CVT For Line
132kV C&R Panels a) Line Protection & Circuit Breaker control panel ( without auto reclose)
b) Transformer protection & Ckt breaker control Panel (without auto reclose ) for LV side of 220/132kV T/F.
c) Bus Coupler Protection & Ckt breaker control Panel without auto reclose (Double Bus bar)
Time synchronization equipment
33 kV VCB 2000A for Bus Coupler & Incomer
33 kV VCB 630A
33 kV Capacitor VCB 630A
33 kV LA’s
33 KV C&R Panels a) 33kV Line Protection & Circuit Breaker control panel ( without auto reclose)
b) 33 kV T/F Incomer C&R panel without autoreclose alongwith 1 no. SEM
c) 33 kV Ckt. Breaker control Panel without auto reclose and capacitor protection Panel
d) 33kV Bus Coupler Protection & Ckt breaker control Panel without auto reclose (Double Bus bar)
33 kV Isolator 630A
33 kV Isolator 2000A for Bus coupler & incomer
33 kV L&E Switch for lines & Cap. bank
33 kV Line cum capacitor CT 400-300/5-1A
33 kV I/C Transformer CT 2000-1000/0.577-5-5-1A
33 kV Bus Coupler CT 2000-1000/5A
33 kV NCT (2000-1000/5A)
21.744 MVAR 33 kV Capacitor Bank alongwith Str. & allied equipments (NCT, Series Reactor etc.) as per specification
220V 200 AH Battery
220 V Battery charger
220 V D.C.D.B. suitable for 200AH Battery
415 V LT AC MCCB Board 500 A
33/0.4 kV Station Transformer 200 KVA with CSP.
100 KVA DG Set along with associated accessories
1.1 kV Copper Control Cable Armoured for 220 kV bays of size 2CX6mm2, 7CX4mm2, 4CX4mm2, 2CX4mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 including Junction box (as per section-6 of copper control cables specifications and Section-7, switchyard erection).
1.1 kV Copper Control Cable unarmoured for 132 kV bays of size 2CX6mm2, 7CX4mm2, 4CX4mm2, 2CX4mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 including Junction box (as per section-6 of copper control cables specifications and Section-7, switchyard erection).
1.1 kV Copper Control Cable unarmoured for 33 kV bays of size 2CX6mm2, 7CX4mm2, 4CX4mm2, 2CX4mm2, 16CX2.5mm2, 10CX2.5mm2, 7CX2.5mm2, 3CX2.5mm2 including Junction box (as per section-6 of copper control cables specifications and Section-7, switchyard erection).
650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. Transformer to ACDB
650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set.
650/1100 Volt 4 core 16 mm2 armoured copper power cable for MLDB and other cable required as per contract for 220kV bays.
650/1100 Volt 4 core 16 mm2 unarmoured copper power cable for MLDB and other cable required as per contract for 132kV bays.
650/1100 Volt 4 core 16 mm2 unarmoured copper power cable for MLDB and other cable required as per contract for 33kV bays.
Earthing Mat Material. The earth mat will be designed / quoted for soil resistivity of 50Ωm. In case soil resistivity is more than 50Ωm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (36631 sq meter approx).
Fire Fighting equipments as per section-6 a) 22.5 Kg Capacity FE CO2 type, Trolley Mounted
b) 25 Kg Capacity FE DCP type, Trolley Mounted
c) DCP 10 Kg Capacity, Wall mounted
d) FE CO2 6.5 Kg Capacity, Wall mounted
e) DCP 5 Kg Capacity, Wall mounted
f) Foam Type 9 Litre Capacity, Wall mounted
g) Water CO2 9 Litre, Wall mounted
h) Fire Buckets(12 Nos with stand in one set)
Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area including all accessories, cables etc. as per clause 16.0 of section 7 of the specifications.
Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets including all accessories, cables etc. as per clause 16.0 of section 7 of the specification
(A) Supply and installation of 35W LED tube fitting on tubular steel poles along Fencing/ boundary wall at a distance of 30 meter including all accessories, cables etc. as per clause 16.0 of section 7 of the specification.
(B)Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station.
(C) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building.
High wall type split AC unit of 2 Ton capacity (as per technical specification)
Testing of IUM System at NABL accredited lab
Complete substation automation system for 220/132/33 kV substations including hardware (along with transducers) & software for present Bays and software for future bay along with associated equipment for the bays as defined in the technical specification, section sub-station automation system as per technical specification. The scope for present and future is as under:- 220kV System Present Bays Future Bays Line Bays 4 2 Transformer Bay 3 1 Bus Coupler Bay 1 - 132 kV System Line Bays 7 - Transformer Bay (I/C) 2 - Bus Coupler Bay 1 - 33kV System Line Bays 5 2 Transformer Incomer Bay 1 - Bus Coupler Bay 1 - Capacitor Bay 1 -
Computer system (SFF) with Intel Core i5, 9th generation processor, 8GB RAM, 1 TB HDD, 19.5 Display with UPS.
Mono chrome Multi-functional Printer,A-4,25 PPM,Wi-Fi
Bolted type 220 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string).
Bolted type 220 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection suitable for twin Tarantula (string).
Bolted type 220 kV Single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and tension clamp sets suitable for single Tarantula (string).
Bolted type 220 KV Single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single Tarantula conductor.
Bolted type 132 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string).
Bolted type 132 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection suitable for twin Tarantula (string).
Bolted type 132 kV Single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and tension clamp sets suitable for single Tarantula (string).
Bolted type 132 kV Single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and suspension clamp sets suitable for single Tarantula conductor.
Bolted type 33 kV single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection and tension clamp set suitable for twin Tarantula (string).
Bolted type 33 kV single suspension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connection suitable for twin Tarantula (string).
Bolted type 33 kV Single tension string assembly with Silicone Rubber Polymer Composite Insulators (E&M strength 9000 kg) with all hardware accessories including ball & socket connections and tension clamp sets suitable for single Tarantula (string).
Boltless C-type Wedge connectors matching with conductor size.
Copper lugs glands, PVC ferrules for control cabling.
Fiber cleats, Aluminium clamps, bolts, nuts, washers etc for fixing control cables in trenches
Galvanised iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2 mm, 100x25x2 mm and 75x25x2 mm and G.I conduits of 50/100mm diameter from equipment to main trench as per Section-7 for Switchyard erection.
2.5” dia HDD/PVC pipe for 4Cx4mm2 control cable from CT, VT to metering system as per Section-5, Chapter-5.
AAC Tarantula Conductor Mtr. (apprx)
7/3.15 GS Earth wire Mtr. (apprx)
Spacers for Twin Tarantula conductor
U-bolt 20mm dia
Item for associated structure work Lattice type steel structure for 220 kV Substation Nain. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 220/132/33 kV switchyard fabricated from steel conforming to IS: 2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner. A. Main Substation tower and beam a) Tower type AT-1
b) Tower type AT-3
c) Tower type AT-4
d) Tower type AT-6
e) Beam type AB-1
f) Beam type AB-2
g) Tower type BT-1
h) Tower type BT-3
i) Tower type BT-4
j) Tower type BT-6
k) Beam type BB-1
l) Beam type BB-2
m) Tower type CT-4
n) Tower type CT-5
o) Tower type CT-6
p) Tower type CT-8
q) Beam type DD-1*
r) Beam type DD-2*
B. a) 220 kV CT drawing No. HTD/ST-147
b) 220 kV NCT drawing No. HTD/ST-150
c) 220 kV PT/CVT drawing No. HTD/ST-147
d) 220 kV surge arrestor drawing No.HTD/ST – 93R
e) 220 kV Bus Post Insulator drawing No. HTD/ST-116
f) 220 kV Isolator/L&E drawing No. HTD/ST-170
g) 132 kV CT drawing No. HHW/ST-67
h) 132 kV CVT/PT drawing No. HHW/ST-67
i) 132 kV PT drawing No. HHW/ST-66
j) 132 kV Surge Arrestor drawing No. HSW/ST- 63R
k) 132 kV Bus Post Insulator drawing No.HTD/ST-144
l) 132 kV Isolator/L&E drawing No. HTD/ST-90R
m) 33 kV LA HTD/ST-89R
n) 33 kV CT drawing HTD/ST-88
o) 33 kV Isolator/L&E HTD/ST-110
p) 33 kV NCT drawing HTD/ST-88
q) 33 kV PT drawing HTD/ST-88
LILO of 220kV D/C PTPS- 220KV Jind Line at 220KV S/Stn. Nain & 400KV PGCIL Jind as under: PLC terminals (No.) 1 No. for 220kV S/Stn. Nain &1 no. for PGCIL 1 No. for 400kV S/Stn. PGCIL Jind &1 no. for 220kv JIND
1 No. at Nain shifted from 220kv JIND
PLC terminal with Prot. Coupler (No.) 2 No. for 220kV S/Stn. Nain & 2 no. for PGCIL 2 No. for 400kV S/Stn. PGCIL Jind & 2 no. for 220kv JIND
2 No. for Nain shifted from 220kv JIND
Wave trap 2 Nos. for 220kV S/Stn. Nain 2 Nos. for 220kV S/Stn. Nain 2 no. for 220kv JIND
LTU (P/P) (Set.) 2 no. for 220kV S/Stn. Nain 1 no. for 220kV S/Stn. Nain & 1 no. for PGCIL 1 No. for 400kV S/Stn. PGCIL Jind & 1 no. for 220kv JIND
48V Battery & Battery Charger (300AH) 1 Nain end
HF cable (kms)
EARTH WORK IN FILLING Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect.
FOUNDATIONS Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work. A. GANTRY TOWERS a) AT-1
B. EQUIPMENT 220kV side a) 220kV LA
b) 220kV Isolator/L&E switch
c) 220kV CVT
d) 220kV PT
e) 220kV CT
f) 220kV Post Insulator
g) 220kV NCT
132kV Side a) 132kV LA
b) 132kV CT
c) 132kv CVT
d) 132kv L&E/Isolator
e) 132kV Post Insulator
33 kV side a) 33kV LA
b) 33kV Isolator/L&E switch
c) 33 kV NCT
d) 33 kV CT
e) 33 kV PT
BREAKER FOUNDATION Design, Engineering, Supply of labour, material and Construction of breaker foundations including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. i) 220kV SF-6 Breaker
ii) 132kv SF-6 Breaker
iii) 33kV VCB
ROADS Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification. i) 6.0M approach road upto main gate
ii) 5.0m wide road within substation land
iii) 3.66m wide road within substation land
CAPACITOR BANK FOUNDATIONS Design, Engg. & supply of labour, material & construction of foundations for following rating capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification. 1x21.744 MVAR 33 kV capacitor bank
ROAD CULVERT Design, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards.
TRANSFORMER FOUNDATION Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & drawing attached. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this account. i) 160MVA. 220/132kV T/F foundation
ii) 100MVA,220/33kV T/F foundation
Design, Engg., supply of labour, T&P and material including RCC, PCC, Reinforcement steel, misc. structural steel & other item(s) not mentioned herein but required for the completion of work as per tech. specs. for construction of below mentioned T/F foundations. i) 200KVA 33/0.4kv Station T/F
ii) 100kVA DG Set
OUTDOOR CABLE TRENCHES Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.
SITE SURFACING i) Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of XEN/Civil Works Division.
ii) Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of concerned XEN/Civil Works Division.
Boundary Wall a) Supply of labour, T&P, material & construction of front, side & U/C boundary walls (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, back filling etc. complete in all respects.
b) Supply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundations as per GELO/CLO, technical specifications & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect. i) 6 ft. high U/C B/wall with barbed wire on angles at top including construction of entrance gate(w/o wicket gate) for yard.
ii) 4½ ft. high front wall including providing grill at top of wall & construction of main entrance gate (with wicket gate).
iii) 4½ ft. high side wall with barbed wire on angles at top of wall.
CONTROL ROOM Supply of labour, material & construction of control room building complete in all respect as per tech. specs. & approved drgs. attached including exterior & interior acrylic emulsion paint, all internal services like water supply including supply & providing of 5000ltr. capacity triple layered Sintex/Diplast PVC tank, sewerage system, staircase, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans , finishing, plinth protection, indoor trenches, trench covers, soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority/ submersible bore (as applicable) etc. & any other item not mentioned herein but required for completion of works. The successful bidder shall also provide water supply connection from bore well/HUDA/Municipal /Public Health or Panchyat water supply scheme (as per available source of portable water) to the control room bldgs. without any extra cost of HVPNL.
U/C FENCING & GATES Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached.
PCC PAVEMENT Construction of PCC pavement in front, rear or side (as per site requirement of the switch house building) as per drawing no. HCD/SK-172 & technical specifications.
DRAINAGE-CUM-RAIN HARVESTING SYSTEM i) Supply of labour, material for construction of recharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below).
ii) The successful bidder shall evolve design & drawing for drains, manholes with RCC covers and settlement tank including preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be located on corner(s) of the s/stn. and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide two no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.
AC Kiosk (RCC Framed Structure) Design, Engineering including architectural and structural drawings of A.C. Kiosk room (RCC Framed structure) ,supply of labour, material and construction of A.C Kiosk room comprising of Anti-Termite treatment, plinth protection, electrification (Ceiling LED tubes with fitting, modular switches, boxes, AC, electric wire etc.), acrylic emulsion and weather proof (exterior acrylic paint), aluminum work (doors/windows/ventilators frames etc), false ceiling, floor finishing,indoor RCC cable trenches,double wall with 50mm thick glass/mineral wool insulation complete in all respect as per technical specification. Items, which are not mentioned but required for completion of work shall be provided by the successful bidder without any extra cost. i) 220 kv Ac kiosk
ii) 132 kv Ac kiosk
iii) 33 kv Ac Kiosk
RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing natural ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing.
sumaja electroinfra pvt ltd
Modern Transformers Pvt. Ltd.
M/s.Mahaveer Electro Mech Pvt Ltd
SMS India Private Limited
TRANSRAIL LIGHTING LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid