| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC 736 PARAGDAS MANDIR NIRMOCHAN GHAT AYODHYA 224123 | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L1 | Accepted-AOC Tender Accepted | |
| 2 | L2₹22.2 L+₹1.3 L (6.33%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹24.5 L+₹3.7 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹26.8 L+₹6.0 L (28.6%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical 161 SADAR BAZAR SADAR BAZAR CANTT AYODHYA UP PIN 224001 | AYODHYA | AYODHYA | UP | 224001 | - | Rejected-Technical rejected |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
23 Jun 2022, 6:00 pmClosed
GE Faizabad
GE MES faizabad
REPAIR MAINT OF PUMP PANELS CLEANING OF UG SUMP AND OH RESERVOIRS AND ALLIED WORKS UNDER AGE EM AT GE FAIZABAD
2022_MES_526569_1
8310/E8
Open Tender
Civil Works
Item Rate
180 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹62,000
Yes
5 Jul 2022
26 May 2022
24 Jun 2022
26 May 2022
23 Jun 2022
9 Jun 2022
Amount
Cleaning of RCC overhead reservoirs internally of capacity 100000 gallons on upto 21 metre high staging including removing deposits, sand etc from inside the tank, scrubbing and washing side walls and bottom of inside tank with bleaching powder solution and making surface free from any fungus/ algae/ vegetation, filling of cavities inside of tank with cement mortar 1:3 mixed with quick settling chemical and applying one coat of white wash inside dome.Writing date of cleaning outside the tank complete all as specified and directed including cleaning of wash out system as required for proper flushing out of dirts/ deposits of over head tank. [Note :- (i) All type of T&P and Labour etc shall be arranged by the contractor and rate for the same deemed to be included in the quoted rate. (ii) Contractor will dispose off the material taken out from the installation at appropriate location upto 50 mtr as directed by Engr-in-Charge]
All as per Item Ser No 01 above but RCC OH reservoir of capacity 50000 gallons complete all as specified and directed
Cleaning of Under Ground Sump internally as well as externally of capacity upto 10000 gallons after pumping out of residual water including removing deposit, sand from inside the sump, scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus/ algae/ vegetation, filling of cavities inside and outside of tank with cement mortar 1:3 mixed with quick settling chemical and applying one coat of white wash inside including top side & writing date of cleaning outside complete all as specified and directed. [Note :-(i) All type of T&P including portable non-clog pump for pumping out residual water before cleaning and Labour etc shall be arranged by the contractor and rate for the same deemed to be included in the quoted rate. (ii) Contractor will dispose off the material taken out from the installation at a distance upto 50 Mtr as directed by Engieneer-in-Charge.]
M&L for applying two coats of cement based paint on all external surface of overhead reservoir of capacity 100000 gallons including coulms and beams of staging up to 21 metre high after scraping/ preparing of old surfaces and two coats of synthetic enamel paint on Inlet, outlet, overflow and washout CI/ GI/ DI pipes and complete staircase as per existing colour from ground level up to top of the reservoir complete all as specified and directed by Engineer-in-charge. [Note: - (i) Before applying cement paint, the surface shall be thoroughly wetted to control surface suction(ii) Not less than 24 hours shall be allowed between two coats and the second or subsequent coat shall not be started until the preceding coat has become sufficiently hard to resist marking by the brush being used]
All as per item No 5 above but for overhead reservoir of capacity 50000 gallons complete all as specified and directed by Engineer-in-charge.
M&L for applying two coats of synthetic enamel paint on Inlet, outlet, overflow and washout CI/ DI pipes and sluice valves and staircase as per existing colour from ground level up to top of the reservoir of capacity 100000/50000 gallons on upto 21 metre high staging after preparing of old surfaces complete all as specified and directed by Engineer-in-charge.[Note: - (i) Different colour for inlet, outlet, wash out, overflow, valves shall be applied as per standard colour code and cost of the same deemed to be included in the quoted rate.]
M&L for applying two coats of synthetic enamel paint on CI/ DI pipes of distribution header including sluice valves of various pump houses after scraping/ preparing of old surfaces complete all as specified and directed by Engineer-in-charge.
M & L for removing honey comb grown on outer surface of RCC overhead reservoirs of capacity 100000/ 50000 gallons on upto 21 metre high staging and applying two coats of cement based paint on the affected area duly matching with the existing colour all as specified and as directed.[ Note:- The work shall be carried out by professionals and department will not take any responsibility in case of casuality caused by honey bees.]
S&F self reflector type flexi board with PVC frame of size 1.2mx0.8m including diagram of water disribution network at each pump house/STP complete all as specified and directed
Chlorine ppm comparator test Kit with colour indicators having 0.1 to 2.0 PPM with Resolution 0.01 pH, make:Avon/ Aquasol or equivalent.
Liquid O-Tolidine solution in sealed bottle of 500 ml
Supply only sodium hypochloride liquid (chlorine content 10%) duly packed in sealed drum of make: M/s Declibac/ M/s Rayalshima Enterprise/ Bajaj Chemicals or equivalent all as specified and as directed.
Supply only lead acid battery 12 volt 180 Ah including initial charge of make: Exide or equivalent complete all as directed by Engr-In-Charge
M&L for Rolled mild steel in Joist ,channel,angle, or tee sections, fixed independently, without connecting plates, etc. for repair to staircase,hand rails,back rest of over head reservoir, gate etc or as otherwise directed. [Note: All T&P including welding machine and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
M & L for connecting Aviation light of capacity 20 watt on top of overhead reservoir at upto 21 mtr high staging including taking out of old one make: Bajaj or equivalent all as specified and as directed [Note: All T&P and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
M & L for Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured with clamps or as ordered for guarding lightning conductor and cable for aviation light along the pillars upto top of over head reservoir at a height of upto 21 mtr all as specified and as directed [Note: All T&P and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
M & L for Aluminium strip 25 x 3 mm with saddles and fixing screws or fixing arrangement as per sitte requirement etc. for roof conductors and down conductors above ground along the pillars upto top of over head reservoir at a height of upto 21 mtr including taking out of old strips all as specified and as directed. [Note: All T&P and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
M & L for Air termination, single pointed aluminium rod 12mm dia and 300mm long for fixing on top of overhead reservoir at upto 21 mtr height including taking out of old one all as specified and as directed. [Note: All T&P and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
M & L for Rigid non-metallic PVC conduit of 40 mm OD exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc along the pillars upto top of over head reservoir at a height of upto 21 mtr all as specified and as directed. [Note: All T&P and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
M & L for PVC insulated and sheathed flat twin core multistranded aluminium conductor of nominal cross sectional area 6.0 sqmm for connecting Aviation light fixed on top of overhead reservoir at upto 21 mtr high staging including taking out of old one all as specified and as directed [Note: All T&P and labour charges for working on OH tanks upto 21 mtr high staging deemed to be included in the quoted rate]
M & L for Tubes, 'light grade', galvanised 25 mm , with all fitting; laid in trenches for protection of LT cables all as specified and as directed
M&L for repair and maintenance of microprocessor based circuit type water level device consist of seven segment 2 " LED display fitted in the control panel with display of water level in tank including replacement and repair of faulty minor parts like IC, level sensor pipe fitted in the tank by clamping at the bottom and the top of the tank,magnetic float and electronic switch, Toggle switch for manual/automatic run of pump when tank is full , heavy duty rubber coated wire (apprx 100 mtrs ) for connecting the sensor to the tank complete all asspecified and directed.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for laying submersible cable in soft/loose soil, taking out excavated material,forming bottom etc complete all as specified and directed..
Returning filling in including,spreading ,levelling watering and well ramming in layer in n.exc 25 cm in soft/lose soil all as specified directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point as in soft/loose soil complete all as specified and directed.
M & L for Hose box made of 18 gauge MS Sheet with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside for yard hydrant (suitable for housing 2 Nos Hose reel drum for 36 m long hose of size not less than 800mm X 600mm X 250mm) including taking out of old one all as specified and as directed
S & F Hose reel drum with hose pipe 36m long including male/ female brass coupling for fixing with fire hydrant valves including taking out of old one all as specified.
S & F Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short including taking out of old one all as specified and as directed
S&F First AID Kit Box-wall mount-multi compartment of size height 32cm, width 28cm,depth 8cm made from high grade GI metal with 6 way processed powder coating for anti rust proof with front glass fitted,3 shelf, security lock on door to accomodate all necessary items such as (i) 1 Burnol tube-12 (ii) 2 Soframycine Cream-24 (iii) 1 Dettol liquid 100ml-12 (iv) 1 Pulse Oximeter (v) 1 Pc Sterlile Wound Dressing-12 (vi) 2 Strip Paracetamol-24 (vii) 3 Electrol Sachet-36 (viii) 3 Sanitiser 200ml-36 (ix) 1 Pc Razor (x) 1 Pc Scissor-12 (xii) 15 Pcs Adhesive Bandage-180 (xiii) 3 Pc Heavy Crepe Bandage width 7.5x3 cm etc-12 etc al as specified and as directed
S & F MCCB 4 pole 100 Amp, 415 volt, 25 KA of make: L&T or equivalent in existing panel including taking out of old one all as specified and as directed
S & F On load Changeover 4 pole 100 Amp, 415 volt, open execution type of make: L&T or equivalent in existing panel including taking out of old one all as specified and as directed
S & F On load Changeover 4 pole 200 Amp, 415 volt, in Sheet Steel Enclosure type of make: L&T or equivalent
S & F digital type Voltmeter with LED display suitable for 3 phase of make: L&T or equivalent in existing panel including taking out of old one all as specified and as directed
M & L for 3 pole power contactor 220/440 volts with 50 Amp AC3 duty rating any type including auxillary switch of make: L&T or equivalent in existing panel including taking out of old one all as specified and as directed
M & L for electronic timer for automatic star delta starter 415 volt 50 Hz 3 - 30 sec of make: L&T, in existing panel including taking out of old one all as specified and as directed
S & F digital type Ammeter with LED display suitable for 3 phase make: L&T or equivalent in existing panel including taking out of old one all as specified and as directed
S & F On load Changeover 4 pole 100 Amp, 415 volt, in sheet steel enclosure type of make: L&T or equivalent including taking out of old one all as specified and as directed
S & F tape wound ring type Current Transformer suitable for Bar primary of rating 100/5 Amp, burden 5 VA of make: Kappa/ Matrix or equivalent in existing panel including taking out of old one all as specified and as directed
S & F Single phase Preventer Relay with adjustable time delay 30 sec to 5 min suitable for 415 volt AC, any type of make: L&T or equivalent including internal wiring from switchgear to relay in existing panel all as specified and as directed
S & F overload Relay any type suitable for 5 Amp to 30 Amp 415 volt AC of make: L&T or equivalent including internal wiring from switchgear to relay in existing panel all as specified and as directed
M&L for Indicator lamp LED type (R,Y,B) complete with bakelite fuse complete all as specified and directed by Engr-in-Charge.
Supply & Fixing of Flat three core submersible cable PVC insulated and sheathed multistranded copper conductor of cross sectional area 16 sqmm of make: Havells , Kalinga ,Polycab or equivalent .
Supply & fixing LED street light fitting 100W Rectangular LED Flood Light with innovative thermal management and available in multiple optics and equipped with IP66 protection with required connection wire multistand 2.5 Sqmm twin core sheathed weather proof up to ACSR conductor/ Ceiling rose and all as specified and directed by Engr-In-Charge. Make:- Cromption cat pat No:- LFLN-100-CDL/60 or Equvalent of Bajaj/Philips
S&F FR PVC Insulated Single core multi stranded unsheathed Industrial Flexible cable of size 16 sqmm conforming to IS 694:2010 with bright annealed copper conductor in existing panel including taking out of old one all as specified and as directed . Make : Polycab or equivalent .
M&L For disconnecting electrically incomming and outgoing LT UG cable of LT panel / AMF panel of any size and replace burn/unsv suitable size of aluminium bus bar, Welding work for hinches and doors, fixing the locking arrangement including scraping outdoor/indoor side of LT Panel and one coat of redoxide, two coat of synthetic enamelled seimens gray spray of outdoor/Indoor side and reconnecting LT UG cable with fixing aluminium lugs by using crimping tool, nut, bolt washer etc and all necesary work required for smooth functioning of LT panel all specified and directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purposeas per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m all as specified and directed.
M&L for Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, connected with GI strip 25x4mm by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI strip is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the equipment. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate, excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009).
S&F only earth lead GI strip 25x4mm complete all as specified and directed
Repair and maintenance of Granular Chlorination Reciprocating dosing pump (Model: 96 NGQ 51), high pressure, single head, gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U.S. GPD and adjustable high pressure of up to 100 PSI including minor spare parts like, tubing, connection nuts, injection check valve, clay weight, ferrules, water inlet pipe line, outlet with strainer,drain pipe, overflow pipe etc complete all as specified and directed by Engr-In-Charge.
Repair and maintenance of submersible pump set any make & model of capacity upto 45 HP including required repairing if any like motor rewinding, replacement of minor spares like CI/ MS bowl (As per existing size), stainless steel shaft with key, stainless steel sleeve, sand guard ,impeller lock with key, neck ring (as per existing size and type), stainless Steel thrust bearing, carbon plate, gun Metal bush, rubber bush, upper housing, lower housing, housing & sleeve repairing on Lathe, rubber gasket, nut bolt and testing after servicing complete all as specified and directed by Engr-In-Charge. [Note: All type of T&P like chain pully block etc and lifting and lowering of motor pump along with column pipe from deep borewellout required at site will be arranged by the contractor and rates for the same deemed to be included in the quoted rate.]
Material and Labour for Mild Steel ERW (Electro Resistance Welded) pipe with flanged ends suitable for Column Pipe of bore dia 150mm ncluding taking out of old pipes all as specified and directed by EIC including taking out of old one. [Note: The pipes should be in 3.0 mtr length with both side flanged suitable for column pipe for Bore well]
Taking out unserviceable sluice valve 100 mm bore from water mains all as specified and directed
All as per item no. 54 but 150 mm bore.
S&F connection & testing sluice valve 100 mm bore 'ISI marked' both ends flanged and drilled cast iron body class PN-1.6 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts and gasket etc for fixing and taking out of old valve complete all as specified and directed of the following sizes :-[Note: For sluice valves fixed with pillars of over head tank, breaking of RCC/lead/ flange joints and repairing the same after fixing of valve deemed to be included in the quoted rates]
All as per item no. 56 but 150 mm bore.
M&L for rectification of leakage of 50mm bore GI Pipe line joints including excavation, returning and filling etc including fittings like unions, sockets, bends, elbows, tees, nipples etc as required complete all as specified
All as per item no. 58 here-in-before but 25 mm bore.
All as per item no. 58 here-in-before but 20 mm bore.
All as per item no. 58 here-in-before but 15 mm bore.
Taking out steel water tubing/ UPVC for 20 mm bore size including fittings complete all as specified and directed.
S & F Unplasticised PVC pipes Sch 40 of fixed complete to walls, ceilings or in floors etc., any type of pipe for 20 mm bore sizes with fittings make: ISI Marked best quality etc complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core
M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- punned thickness only shall be measured & paid
Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
Shree Kanth Technologies
Super Automobiles
Khan Brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .