Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Elegible |
| 2 | Accepted-Technical | Accepted-Technical Elegible |
| 3 | Rejected-Technical | Rejected-Technical Not Elegible |
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
6 Apr 2026, 12:00 pmClosed
Chief Engineer
LDA Gomti Nagar Lucknow
1090 Chuarahe Jiamau Par Navsrajit Commercial Plots ki Suvidha hetu Vikas Karya
2026_LDAUP_1130315_1
261/E-Tender/CE-2025-26
Open Tender
Civil Works
Fixed-rate
90 days
LDA Gomti Nagar Lucknow
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,950
SEC LDA
₹3.6 L
30 May 2026
25 Mar 2026
7 Apr 2026
25 Mar 2026
6 Apr 2026
25 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). | |||||
| 2Mild steel or iron work in plain work such as in R.C.C. or R.B. (when not included in an over all rates ) including bending for proper completion of the work and including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. (SI No. 504) (Sanction Rate) | |||||
| 3Centering and shuttering including strutting, propping etc. and removal of form for :, Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers | |||||
| 4Trenching and Back Filling. Santioned rate. | |||||
| 5Supplying and fixing of 32 mm dia X 2.00 metres long G.l. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. | |||||
| 6Supplying and fixing of light class G.l. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. | |||||
| 7Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect. CAT-AAA SI NO 1451/2018 | |||||
| 8Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer-Incharge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD 501 (i) 6.00 Sqmm 4 Core. | |||||
| 9Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer-Incharge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD 501 (ii) 25.00 Sqmm 3.5 Core | |||||
| 10Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer-Incharge complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD 501 | |||||
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.89 MB
BOQ_2108597.xls
BOQ • 0.24 MB
BIDD.pdf
Tender Documents • 1.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .