Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹13.8 L+₹2.0 L (16.5%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance Not being Lowest | |
| 3 | L3₹14.5 L+₹2.6 L (22.1%)Rejected-Finance | L3 | Rejected-Finance Not being Lowest | |
| 4 | L4₹14.8 L+₹2.9 L (24.4%)Rejected-Finance | L4 | Rejected-Finance Not being Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Does not have requisite category c(ii) as per NIT. |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
6 Jun 2025, 6:00 pmClosed
CWE (AF) Palam
CWE (AF) Palam, Delhi Cantt-10
PERIODICAL, PREVENTIVE AND COMPREHENSIVE MAINTENANCE OF LIFTS IN AREA UNDER GE (AF) PALAM AT AF STN PALAM
2024_MES_671066_4
CWE/PM/N-13/2024-25
Open Tender
Miscellaneous Works
Item Rate
330 days
Palam
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Palam
₹30,000
24 Jul 2025
13 May 2025
13 Jun 2025
13 May 2025
6 Jun 2025
23 May 2025
Amount
Comprehensive maintenance of electrically operated lifts 01 No in each tower of Ground + 3 floor (total four landings) with electric power operated doors, auto electric levelling device of capacity 08 passenger lift installed in CPRU and 101 AW complex Tech area complete all as specified and directed (Total 2 x 11 Month = 22 units lifts ) Location :-Installed at CPRU & 101 complex (SRE Towers )
Comprehensive maintenance of electrically operated lifts 02 Nos in each tower of Ground + 8 floor (total nine landings) with electric power operated doors, auto electric levelling device of capacity 08 passenger lift installed in NCEs DSC Accn at Camp area complete all as specified and directed (Total 4 x 11 Month = 44 units lifts Installed at NCEs/DSC block Camp area) Note for ser. item no. 1 & 2 : (i) The tenderer shall have to replace the unserviceable material only. Contractor is responsible for renewal of insurance. Load testing for lift to be carried out once in a year through a charted Engineer and necessary test report shall be submitted. The entire work mentioned in this Sch'A' including comprehensive , preventive and periodical maintenance of lift/elevators shall be executed through OEM i.e. ECE Industries or authorised dealer .
Notes contd... Guarantee and defect rectification during guarantee period shall be responsibility of the contractor. Third party damage due to malfunctioning of lift shall be responsibility of the contractor . (ii) The comprehensive maintenance shall include weekly , fortnightly, monthly, quarterly , half yearly, inspection / testing/ preventive maintenance replacement of un-serviceable parts/ material including labour , transportation cost . (iii) Contractor shall rectify the defects with in 24 Hrs after receipt of complaints, otherwise the complaint will be rectified by the other agency and the expenditure incurred will be recovered from the contractors dues . The penalty for not attending complaints shall be recovered as per PS clause no. 16. (iv) Old material will be produced to AGE E/M yard by the contractor . (v) The schedule 'A' consists of comprehensive maintenance of M/S ECE lift at NCEs/DSCs block and Tech area SRE tower No.1 and 2 . The work shall be done under OEM/authorised dealer for comprehensive maintenance of lift all as specified in Sch 'A' ser. item no. 1 and 2 above, Special condition particular specification , MES SSR and as directed by GE/ Engr-in-Charge . (vi) The cost of labour required for replacement of spares/ accessories, as mentioned in item No. 3 to 24 hereinafter shall be deemed to be included in the quoted rates.
Notes contd... (vii) Lift mechanic shall be well equipped having good experience in lift/ elevators repair and maintenance . Contractor has to give a copy of qualification ( Minimum ITI) , serving certificate of mechanic . (viii) Contractor shall carryout , monthly quarterly , half yearly inspection and submit the same to Engineer-in-Charge without fail . (ix) The contractor / OEM shall ensure proper functioning of safety devices . (x) Contractor shall provide the mobile number and two Email IDs for regular communication .
Supply only LOP Glass suitable for 8 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only APCLD Card with microprocessor suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only VVVF Door Drive suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only Landing Door Shoe suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only Hanger roller suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only Eccentric Roller suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only pickup for R.H opening 800mm suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only Guide shoe liner 16mm suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only Guide shoe liner 10mm suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only Lock crane R.H & L.H suitable for 8 passenger lifts complete all as specified and directed by Engr-in-Charge.
Supply only Interlocking Rope 800 & 900 opening suitable for 8 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only Reed switch complete all as specified and directed by Engr-in-Charge.
Supply only Limit switch suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only COPVF Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only Apex-01 Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only Apex-02 Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only DO Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only VFVRM Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only PU-10 Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only CPIP Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply only lifts controllers including controller, cabin and material required for lift shaft wiring complete all as specified and directed by Engr-in-Charge.
Supply only Data input Card suitable for 08 passenger lift complete all as specified and directed by Engr-in-Charge.
Supply and fixing cabin fan 300mm size including removing of the unserviceable damaged fan complete all as specified and directed by Engr-in-Charge. (Make : Havells/ Usha/ Orient).
Supply and fix control cable of existing size from panel board to lift control box including removing old unserviceable cable complete all as specified and directed by Engr-in-Charge. (Make :Plaza Cable/ Polycab/Havells/Paragon).
Supply and fixing only Main control LT panel suitable upto 16 passenger lift comprises of a main Mother control unit ,SMPS (5 V 220V I/P) ,Contactor 40 A,Relay card for braking ,a calling card ,4 pole MCB ,U strip connector (40 pieces), Two Rectifier(AC to DC) ,One card Top unit,A land operating panel(LOP) and a Drive Braking Resistance unit(DVR) complete with all accessories complete all as specified and directed by Engr-in-Charge. (Make-ECE/ ThyssenKrupp / Kone)
Rewinding of burnt out lift hoist motor 7.5/10 HP capacity of any make, after disconnecting and removing of the burnt out winding conductor with same size and gauge of super enameled copper conductor, insulating varnishing, greasing, re-fixing back and testing complete all as specified and directed by Engr-in-Charge.
Repairs and maintenance of gear box including cleaning greasing, oiling and replacement of burnt out/damaged parts complete all as specified and directed by Engr-in-Charge.
Repairs and maintenance of safety clutch system including cleaning greasing, oiling and replacement of burnt out/damaged parts complete all as specified and directed by Engr-in-Charge.
BRIJ MOHAN LAL AND CO. (BID ID -3309227)
J D ENTERPRISES (BID ID -3315147)
WVT ELEVATORS PRIVATE LIMITED (BID ID -3309476)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .