Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹18.7 L+₹4.8 L (34.6%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
₹16.1 L
EMD Value
₹32,200
Closing Date
18 Aug 2020, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIRS AND MAINTENANCE OF COOLING APPLIANCES, REFGRIGERATOR WATER COOLERS DEEP FREEZER GEYSERS AT EAST AREA OF GE M AF JALAHALLI BANGALORE
2020_MES_359313_2
8486E8
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹32,200
Yes
26 Nov 2020
10 Aug 2020
20 Aug 2020
11 Aug 2020
18 Aug 2020
13 Aug 2020
11 Aug 2020 - 11 Aug 2020
Amount
Material and labour for servicing/cleaning of complete indoor and out door unit of Ducted Split type / Split Type Air conditioner of following capacity by means of adding cleaning solution with water. The cleaning of the condenser and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge for Ducted Split type AC 8.3 TR Capacity. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item No 1 above but for Ducted Split Type AC 4.0 TR
All as per item No 1 above but for Split Type AC 2.0 TR
All as per item No 1 above but for Split Type AC 1.5 TR
Material and labour for servicing / cleaning of complete water cooler / refrigerator/deep freezer of following size and capacity by cleaning the outer unit by means adding cleaning solution with water. The cleaning of condenser and chiller tubes is done with use of nylon brushes till the scaling is removed for water cooler & deep freezer the inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial and descaling and ensuring its serviceability all as specified and as directed by Engineer-in-Charge for Water cooler of any capacity , make and model. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item No 5 above but for Refrigerator of any capacity, make and model
All as per item No 5 above but for Deep freezer of any capacity, make and model
Attending complaints as per Job card issued by the department for repair / troubleshooting the following cooling appliances / Voltage stabilisers complete including replacement of unserviceable fasteners etc, identification of defective components including replacing, to make unit functional for Ducted Splity type AC 8.3 TR Capacity Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per item No 8 above but for Ducted Split Type AC 4.0 TR
All as per item No 8 above but for Split Type AC 2.0 TR
All as per item No 8 above but for Split Type AC 1.5 TR
All as per item No 8 above but for Water Cooler of any capacity make and model
All as per item No 8 above but for Refrigerator of any capacity make and model
All as per item No 8 above but for Deep freezer of any capacity make and model
All as per item No 8 above but for Voltage stabiliser of capacity 1 to 1.5 KVA
Taking out unserviceable compressor of any type of AC/Refrigerator/Water cooler/Deep freedger, from site and replacement of new compressor against repair of existing make, the compressor sealed unit in position, charging of refrigerant gas suitable type of required quantity, bracing of discharge and suction line and leak testing complete as directed by the Engineer-in-charge for Split Type AC 1.5 Ton capacity
All as per item No 16 above but for Split Type AC 2.0Ton capacity
All as per item No 16 above but for Ducted Split Type AC 4 Ton capacity
All as per item No 16 above but for Ducted Split Type AC 8.3 Ton capacity
All as per item No 16 above but for Water cooler of any make and capacity
All as per item No 16 above but for Refrigerator of any make and capacity
All as per item No 16 above but for Deep freezer of any make and capacity.
Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers and capillary tubes all as required testing complete for the Ducted Split Type AC 8.3 TR including transportation to workshop.
All as above but for Ducted Split Type AC 4.0 TR capacity.
All as above but for Air conditioner Split type 1.5 / 2 TR capacity.
All as above but for Water cooler of any make and capacity
All as above but for Refrigerator of any make and capacity
All as above but for Deep Freezer of any make and capacity
Gas charging with R-134a for Refrigerator and Water coolers in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also)
Gas charging with R-22a for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also)
Supply only Condenser blower motor for Outdoor Split type type AC 1.5 / 2 TR capacity.
Supply only Condenser blower motor of water cooler / deep freezer of any capacity, make and model
Supply only Blower motor of indoor unit of split AC 1.5/2TR
Supply only Fan Blade suitable for 1.5 / 2 Ton Split Type Air conditioner
Supply only Fan Blade suitable for Water Cooler of any capacity / Make
Supply only thermostat for water cooler / refrigerator / deep freezer / Window type ACs of any capacity and make.
Supply only relay for any type of AC / water cooler /refrigerator/deep freezer of any capacity & make.
Supply only OLP for any type of A/C/water cooler /refrigerator/deep freezer of any capacity & make.
Supply only PCB suitable for split /window type A/C 2/1.5 TR of any make.
Supply only wiring kit suitable for split type A/C 2/1.5 TR of any make.
Supply only wiring kit suitable for water cooler/refrigerator/deepfreezer /Window type ACs of any capacity and make.
Supply only starting capacitor 80/ 100 mfd for airconditioner .
Supply only starting capacitor 120 mfd for airconditioner .
Supply only Running capacitor 45 mfd for Split type Air conditioner 1.5 Ton Capacity
Supply only Running Capacitor capacitor 60 mfd for Air conditioner 2 Ton Capacity
Supply only Running capacitor 36 mfd for air conditioner of any capacity & water cooler of any capacity
Supply only auto swing motor for inside unit of split A/C of capacity 2/1.5 TR of any make
Supply only remote control system of split / window type A/C of capacity 2/1.5 TR .
Supply only PVC air filter for split type A/C of any capacity & make .
Supply only contactor suitable for 2/1.5 TR of any make
Supply only contactor suitable for 4 /8.3 TR of any make
Supply only Brass angle valve 5/8 inch for split AC 1.5/2TR capacity.
Supply only Brass angle valve 3/8 inch for split AC 1.5/2TR capacity.
Supply only Copper tubing 5/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply only Copper tubing 3/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply only Puff insulation to suction pipe of split AC.
Supply only Bi-metal for refrigerator
Supply only timer for refrigerator
Supply only PVC ball valves,float valve for water cooler of any capacity & make
Supply only brass chromium plated push button tap outer/Inner thread suitable for water cooler of any type of size 15 mm .
Supply only PCB suitable for capacity upto 5 KVA Voltage stabiliser
Supply only Transformer Suitable for up to capacity 5 KVA Voltage stabiliser
Supply only door lock for refrigerator/Deep freezer any capacity
Supply only baffle tray for refrigerator any capacity
Supply only crisper tray for refrigerator any capacity
Supply only condensor coil for 1.5 Ton Split AC
Supply only condensor coil for 2.0 Ton Split AC
Supply only condensor coil for refrigerator of any capacity
Supply only Evaporator coil for refrigerator of any capacity
Supply only indoor unit for 1.5 Ton Split AC
Supply only indoor unit for 2.0 Ton Split AC
Supply only add on block suitable for 4/8.3 Ton split AC
Supply only timer ET 500 suitable for 4/8.3 Ton split AC
Supply and fix copper cable flexible 3 core of size 2.5 sq mm .rubber insulated
Supply and fix plug top 15 Amp,3 pin conforming to revent IS
Supply and fix plug top 5 Amp,3 pin conforming to revent IS
Taking down the existing window type AC from the wall and Material and labour for closing the existing opening after removing window type AC by closing of opened wall with neccesary brick masonary and plastering including matching with the existing surface all as directed.
Supplying and laying of CPVC pipes 20 mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
Fixing only the Geyser of 25 / 50 Ltr capacity, type, make on Wall including provision of 4 Nos of anchor bolts of suitable size, PVC connection for inlet and cromium plated copper connection for outlet (HOT WATER SIDE)connection making the electric connections, testing and commissionning complete all as directed by Engineer in charge. Note:- Geyser will be isuue under sch 'B' Free for fixing
Attending complaints / servicing including trouble shooting /repair of geyser 25 to 50Ltrs capacity checking of serviceability of individual parts such as thermostat, heating element, pressure release valve, inlet/outlet connections etc, replacing worn-out fasteners and defective components and testing including taking down the geysers and refixing the same after repairs. Note : Spare parts including replacement will be measured and paid separately under relevant item. Rate quoted shall include replacement of worn-out fasteners.
Supply only heater coil of geyser / Solar water heater all as per existing make / model / size conforming to relevant IS for 1.5 KW of any type
Supply only heater coil of geyser / Solar water heater all as per existing make / model / size conforming to relevant IS for 2.0 KW of any type
Supply only thermostat for any type /make/capacity of geyser .
Supply only water inlet & outlet assembly complete of any type /make of geyser complete for the capacity . 50 Ltrs
Supply only water inlet & outlet assembly complete of any type /make of geyser complete for the capacity 25 Ltrs
Supply only pressure release valve 15mm dia with new one for any type /make/capacity of geyser .
Supply only PVC flexible connection of 15 mm dia 600 mm long with check with new one suitable for cold/hot water connection of geysers
Material and labour for GI tubing 20mm dia medium grade in short length with all fittings complete to walls, or laid on roofs including taking down existing unserviceable pipes.
Supply anjd fixing stop valves, fancy type chromioum plated,cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends with iron pipes of 15mm bore including taking down existing unserviceable stop valves
Supply and Fix 20 mm Non return valves, cast copper alloy, for GI Pipes pipe all as directed
Cleaning the surface of geysers 25 / 50 Ltrs capacity to free from dust, grease and preparing surfaces for painting and spray painting with synthetic enamel paint of existing colour including writing MES No. complete all as directed.
Taking the copper or steel container carefully from the geyser, descaling, rectifying leakage by braising, resetting the insulating (glass wool), testing for the required pressure replacing rubber gaskets, worn-out fasteners etc,. with new ones complete all as directed by Engineer in charge.
Removing & Taking down solar water heater of any type & make after disconnecting the electric and water connections plugging the inlet and outlet as required at the building , repairing the solar water heater by removing unservicable parts such as , thermostat,heating element, pressure release valves, rubber gaskets,inlet/outlet connections ,testing for the required pressure, refixing the same in position with nuts and washers complete all as directed by engineer in charge.
Supply anjd fixing copper cable flexible 3 core of size 4 sq mm .rubber insulated
Supply anjd fixing heating element 3 KW, 230V for solar water heater for 200 LPD capacity
Supply anjd fixing heating element 3 KW, 230V for solar water heater for 100 LPD capacity
Supply and fixing Toughened glass 1010 x 2020 x 5 mm for solar pannels alongwith nessary fittings and fixtures including taking down old / broken toughned glass carefully by disconnecting all connects, complete all as directed.
Cleaning of storage tank of solar water heaters of any capacity in position with liquid soap solution, flushing with fresh potable water, sweeping with clean dry cloth and resetting of float valve to maintain the correct level of water in the tank and writting the date of tank cleaning clearly in white letters all as specified by Engineer in charge.
Supply anjd fixing MCB Single pole, 240 volts 5 to 30 Amps 10 KA rupturing capacity for Acs and Geysers of various ratings.
Supply and Fix Base plate of Water Heater of 25 / 50 Ltrs Capacity all as directed
Supply only Indicator Lamp of RED / GREEN Suitable for Water Heater
Supply anjd fixing Solar collector panel of any capacity of solar wtaer heater
Supply only Annode Rods for any capacity of solar wter heater
Supply only rubber pipe for any capacity of solar wter heater
Supply only copper washer for any capacity of solar wter heater
Supply anjd fixing in replacement of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket and offering for credit.
ANAND REFRIGERATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .