Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹32.6 L+₹1.9 L (6.28%)Rejected-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L2 | Rejected-AOC HIGHER THAN L1 BIDDER | |
| 3 | L2₹35.6 L+₹4.9 L (15.9%)Rejected-AOC | L2 | Rejected-AOC HIGHER THAN L1 BIDDER | |
| 4 | L3₹35.4 L+₹4.7 L (15.2%)Rejected-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L3 | Rejected-AOC HIGHER THAN L1 BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical All docus are not found in order |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Sept 2022, 6:00 pmClosed
Maj Srinath PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/MAINT OF LT/HT NETWORK,DISTRIBUTION TRANSFORMER,CALIBERATION OF SWITCH GEAR AND PROTECTION SYSTEM AT CODCANTT UNDER GE (I) KANPUR
2022_MES_549197_1
GE(I)/KAN/T-54 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (I) KANPUR
₹80,000
Yes
22 Nov 2022
1 Sept 2022
6 Oct 2022
1 Sept 2022
29 Sept 2022
17 Sept 2022
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables.
All as per item No-1 but depth exc 1.5 mtr but not exc 3.00 mtr
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed by Engr-in-charge.
M&L for pre cast cement concrete ( 1:4:8) type D2 using 40mm graded stone aggregate for oundation filling of poles as mass concrete.
M&L for pre cast cement concrete ( 1:3:6) type D2 using 40mm graded stone aggregate for foundation filling of stays.
Supply and laying to wall or poles or fixing or passing through pipe, in replacement of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 2 core in service connections complete including taking out old unsv cable of any type,make & cap all as required and directed. Make of cable : Make of cable Havells/Grandlay/kalinga/Polycab. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No 10 but cable of size 10 Sqmm 2 core complete all as specified and directed.
All as per srl item No 10 but cable of size 25 Sqmm 2 core complete all as specified and directed.
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core complete including taking out old unsv cable of any type,make & cap.Make of cable Havells/Grandlay/kalinga/Polycab/Gloster. (Note : Incl making good all distributed wall surfaces/ flooring/tilling to match with existing specification)
All as per srl item No 13 but cable of size 35 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 but cable of size 70 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 but cable of size 95 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 but cable of size 120 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 but cable of size 150 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 but cable of size 185 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 but cable of size 240 Sqmm 3.5 core complete all as specified and directed.
All as per srl item No 13 but cable of size 300 Sqmm 3.5 core complete all as specified and directed.
S&F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 4 core.
All as per item No 22 but for 6 to 25 Sqmm size complete all as specified and directed.
All as per item No 22 but for 50 to 95 Sqmm size complete all as specified and directed.
All as per item No 22 but for 120 to 185 Sqmm size complete all as specified and directed.
All as per item No 22 but for 225 to 300 Sqmm size complete all as specified and directed.
S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 4 core.
All as per item No 27 but for 25 to 50 Sqmm size complete all as specified and directed.
All as per item No 27 but for 70 to 150 Sqmm size complete all as specified and directed.
All as per item No 27 but for 185 to 240 Sqmm size complete all as specified and directed.
Disconnecting electrically and taking out old unserviceable HT UG cables any type of size 70 to 120 Sqmm 3 core all as spfd and directed.
Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened PVC sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 kV rated suitable for earthed system including testing and commissioning all as specified and directed Note : (Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately. Make of cable:- Havells/CCI/Polycab/Gloster
All as per item No-32 above but HT 11 kV cable of size 120 Sqmm.
Supply and fix in replacement of cable straight through jointing kit for 11 kV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm. Make :- Denson/ M seal/ 3 M.
Supply and fix in replacement cable end jointing kit for 11 kV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm. Make:- Denson/ M seal/3 M.
Supply and fix in replacement cable end jointing kit for 11 kV grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 Sqmm. Make :- Denson/ M seal/ 3 M.
Demolition of cement concrete (un-reinforced) in ground, floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified.
M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified.
Boring of holes under road ,pavement and hard standing manually using special T&Ps incl GI pipe of 50 mm dia complete all as specified and directed.
Dismantling from insulators and taking down ACSR conductor any size from HT/LT over head lines and depositing to MES store yead.
Dismantling earth wire/cradles wire any size from eye hooks/insulators etc from HT/LT over head lines and depositing to MES store yard.
Dismantling insulator any type and any size from LT over head lines and fixing other side or depositing to MES store yard.
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside all as required at site or directed.
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and depositing iron item to MES store yard and removing of PCC from site.
Dismantling PCC/steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside for reuse or depositing to MES stores yard.
Locating of cable fault in underground cable by providing of fault locating mobile machine (applying voltage 1.1 to 11 kV) mounted in van along with DG set with T&P at site for locating exact fault pf LT/HT underground cables complete all as spfd and directed.
S & F in replacement of Power / Control Copper Cables, with solid copper conductor, XLPE insulated, 2.5 sqmm, 6 core cut to pieces including making all necessary connections as per site requirement and removing the old unsv control cables from ducts etc complete all as specified and directed by Engr-in-Charge,
Dismantling & taking down old, deteriorated, switch air break of any type and S & F with new 11 kV Isolator Double Stack, vertical Type, 400 Amp, each pole consist of galvanised steel base, HT insulators as per IS, non ferrous knife and spring loaded contact, arcing horns of adequate section to break the magnetizing current, including horizontal G.I. pipe adequate length for phase separation, adequate length of G.I. pipe of 32 mm for operation from ground level and operating handle complete in both OFF and ON position, jumpers with suitable conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontally mounting, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. Make : Jaipuria / Pactel/ Rashtriya.
S & F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and as directed by Engineer-in-Charge. (Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge. (ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
Supply, errecting and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint all as spfd and directed. (Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items)
Disconnecting electrically, dismantling from foundation with due care and setting aside LT/HT fedder pillar box any type any size with all accessories.
Supply and installation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated copper bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35/36 kA of make : Legrand/ Schneider/Havells/L&T complete all as required at site.
S&F in replecement HT 11 kV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work complete all as specified and directed by Engr-in-charge.
M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 1991 or directed by Engr-in-charge ( Excavation, PCC, and loop type insulators will be measured separately).
M&L for loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and directed.
M&L for replacement of GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per srl item No 56 but 50mm bore and complete all as specified and directed.
All as per srl item No 56 but 40mm bore and complete all as specified and directed.
Supply and fix in replecement bus bar chambers 300 mm long iron clad with 4 Nos 200 Amp rated copper strips complete fixed flush wall and making good the disturbed wall surfaces all as a required at site or directed.
All as per srl item No but with 59 Nos 100 Amp.
S & F in replacement of in position retro reflective sign board size not less than 2.5 ft to 2 ft, cut to sizes/shape made out of 3 mm thick high density aluminium sheet fixed on wall with aluminium frame work with all weather effected duly riveted with vinyale sheet based of blue colour base by hot process including letter/number as directed fitted on wall with proper arrangement all as specified. Note : The subject matter which is to be written is to be decided by Enge-in-charge
Repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing of new hinges and other material as required at site complete all as spfd and directed.
S&F in replacement of notice board made out of plywood board with fixing of cloth of best quality green colour supported by aluminium beading complete of size 1.5 mtr x 1.5 mtr fixing on wall with necessary arrangement and one packet of pointing nails multicolour as spd and directed by Engineer-in-charge
Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not esceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M.
M & L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictly all branches in one place as directed by Engineer-in-Charge.
Disconnecting electrically, dismantling from foundation with due care and setting aside old unserviceable LT panel box any type any size with all accessories.
M & L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron frame fixed on RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar not less than 40X5mm suitable for 500 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T,suitable for and including one incoming MCCB 400 Amps 3 pole 35/36 kA, Three Nos 100 Amps 4 pole 25 kA, two Nos 63 Amps16 kA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as required at site or directed. Make : As per Makes approved by CELZ Note: All MCCBs should have adjustble thermal and fixed magnetic setting and Ics will not less than 75%Icu (Make of MCCB: L&T/C&S/Havells/ABB)
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 400 Amps 35/36 kA, thermal magnetic release, Ics will not less than 75%Icu -01 No (incoming). Make : Legrand/Siemens / Schneider /L&T/ABB/C&S.
All as per item No 68 but MCCB 250 Amps 35/36 kA.
All as per item No 68 but MCCB 100 Amps 16 kA.
All as per item No 68 but MCCB 160 Amps 25 kA.
All as per item No 68 but 63 Amps 16 kA.
Detection of any type of fault in HT underground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carring vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required.
M&L in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed incl testing on competion.
All as per srl item No 74 but connected to galvanised iron strip 32x6mm Earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 connected to earth test point all as specified.
M & L for fixing earthing strip 32 x 6 mm GI strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, In Repair,complete all as specified & directed.
M & L for air termination, single pointed, aluminium rod 12 mm dia and 300 mm long at roof top / top most place of buildings including suitable arrangements for fixing with aluminium strip and pointed upwards for observing lightening all as specified and directed by Engr-in-Charge.
S & F in replacement of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amps suitable for 11000 Volts including brackets, clamps, nuts, washers and connecting to 32 x 6 mm GI strip supplied and fixed in replacement complete all as specified and as directed by Engineer-in-Charge. Make: Crompton Greaves / Alsthom / Areva T & D India Ltd / Rastriya
Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretching of ACSR conductor to achieve proper sag and rebinding to the insulators using alumn/GI binding wire and making all existing cable connections complete all as specified and directed.
S&F Aluminium conductor of any size with steel reinforced complete all as specified and directed.
Taking down carefully transformer any capacity, any make, any type from pole / plinth by dismantling, dis-connecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site and shifting/refixing at other location under GE (I) Kanpur after cleaning and making all electrical/earthing connections complete all as specified and directed.
Transportation of Transformer from site E/M yard to workshop for repairing and from workshop to site /E/M yard after repair etc of capacity upto 250 kVA complete all as specified and directed.
Description all as per item No 83 here-in-before but exceeding 250 kVA not exceeding 750 kVA complete all as specified and directed.
Dismantlling top cover of transformer of capacity upto 250 kVA , any make for repair / replacement of HT / LT bushing of transformer or for replacement of top cover gasket or for inspection of transformer or for minor internal repairs of transformer all including draining carefully transformer oil as required / upto the required level and refilling the same, re fixing the top cover of transformer after completion of the work including testing on completion complete all as specified and directed. Note - spare parts will be measured and paid separately under respective items.
Description all as per item No 84 here-in-before but exceeding 250 kVA not exceeding 750 kVA complete all as specified and directed.
Material and labour for dismantling of complete HV/LV coils of transformer upto 250 kVA (11/6.6/0.433 kV) and segregating, serviceable and unserviceable coils, serviceable coils shall kept aside for reuse after complete varnishing and testing of each coil including removal of complete core and accessories such as HV / LV bushings with metal parts, oil temp indicator ,winding temp indicator and disconnection of OTI, WTI complete all as specified and directed. Note : (i) Rewinding of defective HV / LV Coils shall be measured and paid separately. (ii) The rate deemed to be included of all tools and plants.
Description all as per item No 86 here-in-before but exceeding 250 kVA not exceeding 750 kVA complete all as specified and directed.
Dismantling old un-serviceable HT 11 kV bushes and fixing in replacement of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity up to 250 kVA complete all as specified and directed.
Description all as per item No 88 here-in-before but exceeding 250 kVA not exceeding 750 kVA complete all as specified and directed.
Dismantling old un-serviceable LT bushes and fixing in replacement of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 250 kVA complete all as specified and directed.
Description all as per item No 90 here-in-before but exceeding 250 kVA not exceeding 750 kVA complete all as specified and directed.
Repairs to the leaks of transformer of any cap from tap switch/ fins/ any pats of body, by replacing gasket / seal, or Repairs to the leaks of transformer body / fins, by welding / brazing etc complete all as specified and directed.
M&L for taking out old burnt winding and rewinding of HT/LT coil of different type, capacity and make of transformer with approved quality supper enamelled copper wire/ strip of approved make of suitable gauge and number of turns along with allied materials like cork sheet, fibre glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass) soldering and other packing material etc. all as required at site complete all as specified and directed.
S&F Top gasket made of 3mm thick cork sheet with suitable holes for 11/6.6/0.433 kV transformer of any type/capacity including providing suitable size of bolts, nuts and washer for transformer top cover complete for any capacity/size transformer complete all as specified and directed.
Disconnecting electrically, open the cover of transformer any type/size and filtration and dehydration of Transformer oil for 11 / 6.6 / 0.433 kV transformers, with stream line mobile filtration plant (To be provided by contractor & quoted prices deemed to include its hire charges) at a temp from 60-75 degree celsius to achieve the dielectric strength of oil 60 kV or over at standard gap as per IS 335 of 1993 (Fourth revision) to remove the moisture from winding and core complete all as specified and directed. Note : (a) Filtration should be carried out in OFF position, therefore generator and cables will have to be arranged by the contractor at his own cost. (b) Test result will be recorded before and after filtration of oil and submitted to Engr-in-Charge in a prescribed manner.
M&L for Open the cover of transformer any type/size on site/ in workshop for rep & maint and filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 including heating of oil and die-electric strength 40 kV when tested at 4mm gap complete all as specified and directed.
S&F in replacement of temperature gauge circular dial type of standard size and dia suitable for indoor/outdoor type transformer upto 400 kVA complete all as specified and directed.
M&L for replacement and full fill up fresh silica gel in assembly at site complete all as directed and specified.
Servicing / Calibration to 11/6.6 kV HT VCB complete including the following (a) Taking out 11/6.6 kV HT VCB of 630/800/1250 Amps rating trolley from HT Panel after switching off electric supply. checking of mechanical system for proper functioning of upward / downward movement of HT VCB trolley including opening the VCB & checking the mechanical system. cleaning & servicing the fixed / moving contact & blowing out dust and applying the proper lubrication / greasing and reassembling the VCB / SF6 including connection to HT panel complete insulating oil to be replaced where reqd complete all as directed and specified. (b) Taking out relay set of any make from HT 11/6.6 kV VCB panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC. (Note for (a) & (b):- (i) Replacing new items shall be measured and paid separately as supply only. Note : Minor spares if required shall deems to be included with the above job.
Supply only shunt trip coil assembly suitable for HT, VCB panel 11/6.6 kV, operating on 30 / 110 volt system and testing complete all as specified and directed.
Supply only closing / tripping coil operated on 110 / 30 volt system as per sample suitable for working of relay of HT VCB panel complete all as directed and specified.
Supply only fabricated gears as required for spring charger of VCBs as per sample.
S & F in replacment charging motor for 11 kV, VCB, 1250 Amps operated on 230 volts DC as per sample complete all as specified and directed.( Make:- Electra / Delco or equivalent as approved by GE ) .
M&L for the CTs of ration 200/100/5, with 5 P 10 for protection and class-I accuracy having 15 VA burden all as directed by Engr-in-charge.
S & F in replacement indication lamp (LED type) Red or Yellow or Green colour suitable for 110 volts AC / 110 volt DC / 30 volts DC (as required at site) complete all as specified and directed.
M & L for cleaning,rubbing,preparation for painting all surfaces of Steel tubular poles 9/11 mtr with security light bracket or clamps,channels etc complete and painting all surafces of the same with AL paint 2 coat complete with black & yellow stripes (total 5 nos with 30 cm width from bottom of poles) complete all as specified and as directed by Engr-in-charge.
S & F in replacement Air circuit breaker 1000 A cap 3P, 50 kA manual draw out type thermal magnetic type ,micropro – communication compatible with RS485 modbus protocol conforming to IS/IEC 60947-2 & IEC 60947-2, Dual spring balanced mechanism com[plete with all accessories as per spe cified amd directed by Engr-in-charge. Make : C&S/Seimens/ABB/Legrand
Supply and fix in replacement Gate light fitting LED type 25 W with CCT not less than 5700 K ,and IP 65 Protection ,230V recessed mounting mirror opticluminare complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, Make : Havells /HPL/Indoasian complete including wire and making connection complete with pole all as specified and directed by Engr-in-charge.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections used for security light connections from cable to beacket on poles, twin core cable flat or circular 10 sqmm solid conductor complete all as specified and as directed.
M & L for MS work with hand rails ,half round or other stock section ,drilled and countersunk for balusters running bars,including embeding in concrete and screwing etc , struts in fencing including cutting tops to shape as directed ,drilling holes ,notching for wire etc,flat iron fillets (for securing wire mesh/XPM net etc) including all necessary drilling ,bolting or riveting and similar work conforming ton Fe--290 Gde E-165,with two coats synthetic black paint on steel surfaces complete complete including dismantling of old detoriated fencing and cement concrete type B-2 1:2:4 (40 mm graded having 100 mm thick) complete all as spd and directed.
M & L for PVC coated chain link fencing with mesh size 50X50 mm, GI wire dia not less than 4 mm and final PVC coated diameter should not less than 5 mm, height not less than 1 mtr from the plateform, colour of mesh will be decided by Engr-in charge and fixed complete to MS angles complete all as spd and directed. NOTE: MS angles will be measured in item no 110.
M& L for replacement of battry bank of 30V/100 amp (15 cells of 2V per cell) of battery charger complete with dismantling one & connection complete all as directed by Engr-in-charge Make: Exide/Amron/ equivalent complete all as specified and directed.
DEO Traders
Ashirwad Contractor and Supplier
S B ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .