Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹9,400
Closing Date
15 Oct 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
3rd Floor Purta Bhavan, Sarat Sarani Kodalia Hooghly
SITC of Spilt Type AC Machines along with Electrical Installation Work at DLSA Building, Serampore, Hooghly
2026_WBPWD_5021938_1
WBPWD/EE/ HED / NIeT-82 (2nd Call) of 2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Hooghly
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,400
O/O the E.E,HED,PWD,
17 Oct 2026
3 Sept 2026
17 Oct 2026
3 Sept 2026
15 Oct 2026
3 Sept 2026
7 Sept 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [7(a)/ E-16 ] | 112 | Mtr. | 1.25 | ₹140 |
| 2 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/ E-17] | 7 | Each | - | - |
| 3 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [5(b)/ E-17] | 7 | Each | 100 | ₹700 |
| 4 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17/ E-19] | 7 | Each | 100 | ₹700 |
| 5 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
[1(v)/ E-9] | 112 | RM | 1.25 | ₹140 |
| 6 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes
2.5 sq mm [9(i) / F-5] | 14 | Set | - | - |
| 7 | 4 sqmm [9(ii) / F-5] | 28 | Set | - | - |
| 8Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on the compressor and 1 year warranty on PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC.(Daikin/Hitachi/Carrier/Blue star/Voltas) | |||||
| 8.1 | Cooling Capacity- 5.2 kW (Minimum) , Air Flow Rate:600 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) [Item 2.2/Page 2] | 4 | Each | 100 | ₹400 |
| 8.2 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) [Item 2.3/Page 2] | 3 | Each | 100 | ₹300 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.36 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_5101500.xls
BOQ • 0.35 MB
time15102026.pdf
PDF • 0.72 MB
time12102026.pdf
PDF • 0.72 MB
time29926.pdf
PDF • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .