Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹57.3 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹60.3 L+₹1.4 L (2.38%)Rejected-Finance 143 RAM GALI HAJINDER NAGAR II KANPUR UP PIN 208007 | KANPUR NAGAR | UTTAR PRADESH | 208007 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹69.9 L+₹11.0 L (18.7%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | Rejected-Technical 548 C 259 CHANDRODAYA NAGAR DEOPUR PARA LUCKNOW 226017 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226017 | - | Rejected-Technical Rejected due to Sr No 8 (b) (v) of Appx A to NIT | |
| 5 | Rejected-Technical 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | - | Rejected-Technical Rejected due to adverse remark in WLR of Pune |
Tender Value
₹75.5 L
EMD Value
₹1.4 L
Closing Date
29 Mar 2023, 6:00 pmClosed
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Pin-208008
SPECIAL REPAIR TO OLD OBSOLETE HT, LT CABLE, BER TRASFORMER CAPACITY 3.15 MVA AT MRS AND ASSOCIATED E/M WORKS AT VARIOUS LOCATION AT AFS KANPUR
2023_MES_582634_1
CA No.CWE(AF)/CHK/EM/T-39 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) E/M Chakeri
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) E/M Chakeri
₹1.4 L
20 Apr 2023
23 Feb 2023
31 Mar 2023
23 Feb 2023
29 Mar 2023
16 Mar 2023
Amount
Supply, install,testing, & commissioning outdoor type Power transformer having no load voltage ratio at rated voltage 33/11 KV, 3150 KVA oil immersed, naturally cooled 3 phase 50 Hz, vactor group DYN-11 and ON Load tap Changer with AVR & RTCCP +5% to -15% in step of 1.25% tap changing switch on HT side to very secondary voltage, connected internally and hand operated ON circuit tap changing switch, star Delta connected internally with HV coil, copper double wound, LV side provided with 3 phase and neutral with the temprature rise not exceeding 60 degree C by thermometer in oil and 55 degree Celsius by resistance with first filling of oil as per IS grade 335 and transformer conforming to IS 2026 level 1 insulation level "class A" all as directed and specified with and including the following fitting and accessories including first fill of transformer oil necessary mounting on PCC floor mounted as per manufacturer's recomendations and specifications
(a) Lifting lugs, Top cover lugs & jacking Pad.
(b) Earthing Terminals.
(c ) Conservator with oil gauge Glass, Oil filling hole with plug and drain plug.
(d) Transformer Drain valve
(e) 04 Nos Bi Directional plain/Flat rollers
(f) Explosion Vent with Diaphragm
(g) Thermometer Pocket
(h) Air Vent Plug
(j) First Fill Silica get Breather
(k) Rating & Diagram Plate, Inspection cover,. Terminal Making Plate
(l) Cooling Radiators
(m)LV Neutral Bushing brought out for external earthing.
(n) First Fill of EHV grade Transformer Oil
(o) Buchholz Relay with Contracts for Alarm & Trip Contacts
(p) Magnetic Oil Level Gauge with Alarm Contacts
(q) Oil Temp indicator with Alarm & Trip Contacts
(r) Winding Temprature indicator with Alarm & Trip Contacts
(s) Marshaling Box)
Supply ,laying and testing XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured HT electric power cable heavy duty with aluminium conductor 11000 volts grade earthed cross sectional area 300 sq mm 3 core, laid in ducts including taking out existing unserviceable cable complete all as specified and directed.
Supply & Fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm all complete as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sqmm 4 core, 1100 volt grade including taking down of existing unserviceable cable complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sqmm 8 core, 1100 volt grade including taking down of existing unserviceable cable complete all as specified and directed.
Supply ,laying and testing XLPE insulated armoured heavy duty LT electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 95 sq mm 3.5 core ,laid in ducts including taking out of existing unserviceable cable complete all as specified and directed
Supply ,laying and testing XLPE insulated armoured heavy duty LT electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 120 sq mm 3.5 core ,laid in trenches/ducts /encased in GI pipe /fixed to pole including taking out of existing unserviceable cable complete all as specified and directed
Supply ,laying and testing XLPE insulated armoured heavy duty LT electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 150 sq mm 3.5 core ,laid in ducts including taking out of existing unserviceable cable complete all as specified and directed
M&L for Earthing (in replacement) complete with copper earth plate electrode of size 600 mm x 600 mm x 3.15 mm thick buried directly to ground vertically to a depth not less than 2.25 m below the ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to copper strip 32 x 6 mm size as earthing lead filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to copper strip by means of GI nuts, bolts and washers strip connected to earth test point including chamber PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) alongwith lifting handle complete all as specified and directed.
M&L for Earthing (in replacement) complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 m below the ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI strip 32 x 6 mm size as earthing lead filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth test point including chamber PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) alongwith lifting handle complete all as specified and directed.
M.S CONSTRUCTIONS
KB PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .