Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹11.2 L+₹1.2 L (12.5%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹11.9 L+₹1.9 L (19.4%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance Not Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Recommended as contractor is not enlisted in requisite category | |
| 5 | Rejected-Technical SAHEED UDHAM SINGH NAGAR THANDI KHUEE SUJANPUR PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | - | Rejected-Technical Not Recommended as contractor is not enlisted in requisite category |
Tender Value
Refer Docs
EMD Value
₹13,840
Closing Date
26 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
PROVN OF SPLIT ACs FOR MI ROOM AT 167 MH UNDER GE SOUTH PATHANKOT
2022_MES_531983_1
GES/PKT/T-19/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹13,840
Yes
16 Aug 2022
18 Jun 2022
28 Jul 2022
18 Jun 2022
26 Jul 2022
4 Jul 2022
60 days
Amount
Supply and install hi wall split units indoor/ outdoor complete with cordless remotecontrol unit and with cooling and heating function of capacity 1.5 TR 3 star rated complete all as specified and as directed.
Supply and fix water heater storage vertical type, SS tank, polycarbonate body electrical operated, capacity 25 litres.BEE 5 star rated duly fixed on wall through proper anchoring, grouting with the help of suitable nuts and bolts, and making good all the disturbed surface all as specifed and directed.
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 50 Sq mm 3.5 core.
Supply, laying and testing cable XLPE Insulated screened , PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
S & F in replacement existing unsv distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
Supply and draw sub main wiring in repairs of two run 4.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 2.5 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical, plate No. 5 connected to earthing test point all as specified or indicated including testing on completion.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtrs in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. (cable shall be laid 60 cm below ground level )
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
Cutting existing steel tubing for alteration including screwing in position for branch connecting size 15/20/25mm bore complete.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm suitable for hot and cold water all as specified and directed
S&F brass angle valve, cromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm dia.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15 mm dia all as specified and directed
S&F in replacement iron clad, with double door 4 way IP-54, 1K-09 protection, cement sprill prptector sutable for MCCB as incommmer AC 415 Volts three pole with thermal release adjustable type (80% to 100%) and MCB as outgoing complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 ple 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at sit or directed. (Outgoing MCB will be measured speparately)
S&F for SPN 40 to 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
M&L for GI tubing medium grade of 15 mm dia complete all as specified and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed
Supply and fixing GI tubing light grade ISI marked with requisite fittings laid in trenches or crossing roads/ paths/ culverts/along poles/walls complete all as specified and directed for 50 mm dia size.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Material, labour , testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 10 Sqmm to 25 sqmm 3½ or 4 core with working voltage 1100 volts make: Denson/ M Seal/Raychem.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .