| Sl No | Description | Qty | Unit | WEDWAY INDUSTRIES L1 | SRI RAVI BALAJI ERECTORS L2 |
|---|---|---|---|---|---|
| 1.00 | Testing and calibration of electrical equipment’s at MRT control / Power Lab. Charges for assisting, testing of relays/ contactors/ Switches and calibration of meters. | 400 | Opn | 700 ₹2.8 L | 710 ₹2.8 L |
| 2.00 | Routine cleaning maintenance of control and protection panels and testing assistance activities pertaining to Generator auxiliary system, 230 KV Switchyard and MRT lab. | 104 | Opn | 120 ₹12,480 | 120 ₹12,480 |
| 3.00 | Routine maintenance of cleaning and visual inspection of relays in HT/LT switch gear system. | 400 | Opn | 13 ₹5,200 | 14 ₹5,600 |
| 4.00 | Charges for reconnection of control cables, setting of open/ close limit/ torque switches and checking of operations instructed by the maintenance Engineer incharge. | 100 | Opn | 820 ₹82,000 | 820 ₹82,000 |
| 5.00 | Charges for transporting the testing equipment to transformer yard, assisting for conducting OCC, SCC tests on GT, UAT’s (A&B) and its NGT, terminal tightness checking in marshalling boxes, metering and protection CT’s. | 10 | Opn | 8,500 ₹85,000 | 8,500 ₹85,000 |
| 6.00 | Charges for transporting the testing equipment to transformer yard, assisting for conducting OCC, SCC tests on ST1 & ST2 and its NGT, terminal tightness checking. | 4 | Opn | 5,300 ₹21,200 | 5,300 ₹21,200 |
| 7.00 | Charges for transporting the testing equipments and tools to Ash handling swgr, Central Control panels, Ash handling transformer and Bottom Ash hopper and for assisting the testing of HT/LT breakers such as HT breakers pole Resistance/contact resistance, Opening / Closing timings, HT/LT motors, Relays /Meters and Checking the bottom ash hopper feed gate actuators and their operation. | 64 | Opn | 4,200 ₹2.7 L | 4,200 ₹2.7 L |
| 8.00 | Charges for transporting the testing equipments and assisting for HT breaker pole resistance and opening/closing time measurement. | 220 | Opn | 1,480 ₹3.3 L | 1,480 ₹3.3 L |
| 9.00 | Charges for transporting the testing equipments and assisting for HT breaker contact resistance during BUS LC. | 220 | Opn | 1,480 ₹3.3 L | 1,485 ₹3.3 L |
| 10.00 | Charges for transporting the testing equipments and assisting for Testing of P.O/Spare/field equipment/ materials/cable fault locations at field / Central Stores. | 180 | Opn | 510 ₹91,800 | 510 ₹91,800 |
Tender Value
Refer Docs
EMD Value
₹27,900
Closing Date
21 Jan 2025, 2:00 pmClosed
SE/ES/NCTPS-I
Superintending Engineer Electrical System NCTPS I Chennai 120
NCTPS I ES Circle MRT Dn SD IV Time bound works contract for the maintenance of MRT equipments for a period of 360 days at NCTPS I
2025_EB_517122_1
CE/NCTPS-I/SE/ES/WC-51/2024-25
Open Tender
Power/Energy Projects/Products
360 days
NCTPS-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹27,900
Yes
26 Mar 2026
7 Jan 2025
22 Jan 2025
7 Jan 2025
21 Jan 2025
7 Jan 2025
Amount
Testing and calibration of electrical equipment’s at MRT control / Power Lab. Charges for assisting, testing of relays/ contactors/ Switches and calibration of meters.
Routine cleaning maintenance of control and protection panels and testing assistance activities pertaining to Generator auxiliary system, 230 KV Switchyard and MRT lab.
Routine maintenance of cleaning and visual inspection of relays in HT/LT switch gear system.
Charges for reconnection of control cables, setting of open/ close limit/ torque switches and checking of operations instructed by the maintenance Engineer incharge.
Charges for transporting the testing equipment to transformer yard, assisting for conducting OCC, SCC tests on GT, UAT’s (A&B) and its NGT, terminal tightness checking in marshalling boxes, metering and protection CT’s.
Charges for transporting the testing equipment to transformer yard, assisting for conducting OCC, SCC tests on ST1 & ST2 and its NGT, terminal tightness checking.
Charges for transporting the testing equipments and tools to Ash handling swgr, Central Control panels, Ash handling transformer and Bottom Ash hopper and for assisting the testing of HT/LT breakers such as HT breakers pole Resistance/contact resistance, Opening / Closing timings, HT/LT motors, Relays /Meters and Checking the bottom ash hopper feed gate actuators and their operation.
Charges for transporting the testing equipments and assisting for HT breaker pole resistance and opening/closing time measurement.
Charges for transporting the testing equipments and assisting for HT breaker contact resistance during BUS LC.
Charges for transporting the testing equipments and assisting for Testing of P.O/Spare/field equipment/ materials/cable fault locations at field / Central Stores.
Charges for transporting the testing equipments, cable connections and assisting for Tan-Delta testing of Generating Transformer, 230 KV Bushings, 230 KV CTs, Generator ,230KV CVTs, UATs, Excitation Transformer, STs, HT Motors during AOH/LC.
Charges for transporting the testing equipment, Cleaning & assisting for conducting the tests on HT Relay Panel.
Charges for transporting the testing equipment, Cleaning & assisting for conducting the tests on LT Relay Panel
SRI RAVI BALAJI ERECTORS (BID ID -1234836)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_615367.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid