Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹16.5 L Quoted ₹17.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹19.8 L+₹2.5 L (14.1%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹19.8 L+₹2.5 L (14.1%) | L2 | Rejected-AOC Not Being L1 |
| 3 | L3₹34.1 L+₹16.7 L (96.3%)Rejected-AOC M S SATHYAM ENGINEERING KOOTHANKUZHI THIRUVALLUR TAMIL NADU 600 062 | THIRUVALLUR | THIRUVALLUR | TAMIL NADU | 600062 | ₹34.1 L+₹16.7 L (96.3%) | L3 | Rejected-AOC Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 Aug 2023, 6:00 pmClosed
Garrison Engineer, Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai
Repair /replacement of L2 Chemical Earthing, Conventional Earthing and Maint of fire alarms system and allied works at AF Tech area and Repair and maintenance of Earthing infrastructure, Lightening protection and arrestor and connected allied works
2023_MES_609726_1
8119
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Avadi
₹50,000
10 Nov 2023
19 Jul 2023
26 Aug 2023
19 Jul 2023
18 Aug 2023
3 Aug 2023
Amount
M&L for earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using copper strip 20 x 3mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised iron strip 25×4mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 3.15mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1: 2: 4 type C2 including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) all as specified and directed by Engr-in-Charge.
Material and labour for chemical earthing Providing tripod maintenance free earth pits using back fill compound of 75 Kg (Min) ,earth electrode of copper rod /copper bonded steel rod of 3 mtr length (min) & 17.2mm dia complete with test links for cable connection/disconnection,RCC chamber outer dia 400x400,inner dia 300x300 and depth 300mm with top cover including excavation,refilling etc complete all as specified and directed.
Material and labour, test point terminal block made of gun metal or phosphorus bronze or copper, size 75mmx75mmx25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws, complete all as specified and directed.
Material and labour, Earth continuity conductor or main earthing conductor 20mmx3mm copper strip, fixed to wall on batten with saddles and fixing screws or PVC/ Porcelain insulators etc. or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, including brazing on both sides (over lapping) at all joints complete all as specified and directed.
Material and labour, Earth continuity conductor or main earthing conductor 25mmx4mm galvanised iron strip, fixed to wall on batten with saddles and fixing screws or PVC/ Porcelain insulators etc. or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, including brazing on both sides (over lapping) at all joints complete all as specified and directed.
Material and labour, Earth continuity conductor or main earthing lead or lightning conductor, 25mmx3.15mm aluminium strip, fixed to wall on batten with saddles and fixing screws or PVC/ Porcelain insulators etc. or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing or roof conductors and down conductors etc. as required, including brazing on both sides (over lapping) at all joints except test point, fixed as in replacement of existing strip, complete all as specified and directed.
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed by Engr-in-Charge
Material & labour, brazing/ soldering on both sides (over lapping) to the copper strip of size 20mmx3mm and 25mmx3mm as earthing lead, including dismantling the old from the existing position/ equipment without disturbing the functional requirements of the equipments, and reconnecting, after repair/brazing, complete all as specified and directed.
Material and labour, plain cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate, for foundation etc, including use and waste necessary form work, and fair finishing the expose surfaces using extra cement @ 1.2 Kg/Sqm. complete, all as specified and directed.
Demolition and dismantling of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.
Material and labour for Cement concrete in foundations, filling and mass concrete for 1:2:4 Type B-02 40mm graded aggregate complete all as specified.
Supply and Fixing of Rigid non-metallic PVC conduit for 40 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc fixed on walls with suitable clamps on ceiling / roof trusses etc complete all as specified.
M&L for GI tubing light grade laid in floors, on wall and fixing in steel trusses for earth strip protection of size 40 mm dia complete all as specified and directed.
Material and labour, Air termination, single pointed aluminium rod 12mm dia and 300mm long, including making connection to earthing conductor, fixed as in replacement of old termination rod, complete all as specified and directed.
Supply and fix, GI pipe 25mm bore light grade (ISI marked), cut piece of 1.0 metre - 1.5 metre length or as directed by Engineer-in-Charge, fixed vertically with bottom end embeded in & including cast-insitu PCC (1:2:4) block of size 20cmx20cmx15cm including use and waste necessary fair finish form work, and other end (at top) fixed to air termination rod with necessary bolts, nuts etc as required, complete all as specified and directed.
Supply and fixing for 50 sqmm single core flexible copper conductor cable (ISI marked) from Eqpt upto earth pit i/c of any meter all accessories like PVC sleeves ,saddles/clamps/insulator etc complete as per specification and as required at site.
Supply,install ,testing and commissioing of lightning flash/strike counter in water and weather proof , digital display facility,current discharge capacity >1KA,,IP 65 Protection with enclosure for analyzing the frequency of lightning strikes and effectiveness of the lightning protection system in place and connected to down conductor with mounting arrangements with GI Mast tower or Building wall surface and suitable fixing arrangements with standard accessories etc complete as per specification and as required complete all as specified.
Supply and fixing, porcelain supporting insulator of as per existing size/adequate size fixing, on wall/roof for supporting the lightning arrester earthing strips, fixed as in repairs, complete all as specified and directed.
Labour only, testing of earth resistance value using megger and record the reading in register, and retesting and record the reading after making arrangement as to achieve earth resistance with in permissible limit with help of saline water, salt, charcoal, magnesium suphate etc. Complete all as specified and directed. Note: (i) Salt, charcoal/coke, magenesium suplhate (MgSO4), shall be measured and paid for separately as material labour under relevant items. (ii) Testing shall be done every 3 month interval and value will be noted with user signature.
Material & labour, brazing/ soldering on both sides (over lapping) to the copper strip of size 20mmx3mm and 25mmx3mm as earthing lead, including dismantling the old from the existing position/ equipment without disturbing the functional requirements of the equipments, and reconnecting, after repair/brazing, complete all as specified and directed.
Material & labour, Supply of salt and mixing in water, and pouring into earth pit through watering pipe of chamber, in adequate quantity as to maintain earth resistance value within permissible limit, complete all as specified and directed.
Material and labour, Supply of Charcoal/coke powder, mixing in water and pouring into earth pit through water pipe of chamber, in adequate quantity to maintain earth resistant value within permissible limit, complete all as specified and directed.
Material and labour, Supply of magnesium sulphate (MgSO4), mixing in water and pouring into earth pit through water pipe of chamber, in adequate quantity to maintain earth resistant value within permissible limit, complete all as specified and directed.
Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed on wall/ ceiling / roof trusses etc. and connecting to common earth dolly complete including taking down unserviceable submain wiring with accessories all as specified and as directed.
Supply and Fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified.
Repair and rectification of fault for Fire Alaram panel addressable type multi sensor and detectors with connected accessories rectification of any fault occured at fire alaram panels and detectors including internal wiring and provision of DC battery back (02 Nos-6v) with connected accessories complete all as specified. Make:- Ravel/Airlight
Supply and Fixing of detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 with connected and fixing accessories complete including taking down unserviceable smoke detector with accessories all as specified and as directed.
Supply and Fixing of detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination Photoelectric /Optical with base with self built intelligence as per IS: 11360 with connected and fixing accessories complete including taking down unserviceable multisensor detector with accessories all as specified and as directed. ditto but Addressable type multisensor detector with heat and smoke combination
Supply and Fixing of detectors Complying with and type certified to EN - 45 Addressable type heat detector with base with rate of rise cum fixed temperature as per lS:2175 Photoelectric /Optical with base with self built intelligence as per IS: 11360 with connected and fixing accessories complete including taking down unserviceable heat detector with accessories all as specified and as directed.
PSK Enterprises
Sathyam engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .