CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
REPAIR AND MAINT OF WINTER APPLIANCES AND CONNECTED ITEMS AT NIWARU MIL STN
2024_MES_676693_1
CWE/JPR/82421/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JAIPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE JAIPUR
₹18,000
Yes
19 Dec 2024
26 Sept 2024
26 Oct 2024
26 Sept 2024
24 Oct 2024
10 Oct 2024
26 Sept 2024 - 10 Oct 2024
Amount
Taking down storage type water geysers of 25 ltrs capacity any type any make, any model, from its existing location, transportation to work shop for repairs and transportation back and reinstallation of geyser as per technical instructions and as directed by engr-in-charge and including the following:- (a) Dismantling complete geyser and carrying out complete overhauling i.e disconnecting electric supply and opening the heating plate, inner assembly, descaling complete assembly including heating element or otherwise. Replacement of defective heating element inlet and outlet tubes and refixing the assembly with gasket of good quality and tightening the nuts properly, reassembling geyser with all safety devices as specified in technical instructions and as directed by Engineer -in- Charge complete. Notes:- (i) Spare parts, safety devices with its required accessories shall be measured and paid seperately as supply only rates here-in-after . Notes:- (i) Spare Parts,Safety devices with it required accessoriesshall be measured and paid saperately under respective items of schedule as supply only labour for fixing the same are deemed to be included in rate quoted.
Supply only following parts of geysers 25 Ltrs capacity of make Bajaj/Havells/Usha/Venus/ or equivalent ISI marked ( Make of parts shall be as per make of Geysers):-
Heating element 2 KW suitable for operation on 230V AC 50Hz
Heating element 1.5KW suitable for operation on 230V AC 50Hz
Thermostat 40 to 90 degree centigrade varying capactiy for 25 Ltrs capacity Geyser.
M& L for replacement of inlet/outlet assembly suitable for storage water heater of capacity 25 Ltrs having provn of any make housing thermostat, heating element including connected accessories provinding rubber gasket and holding nut bolts complete all as specified and directed.
M& L for fasteners suitable for hanging of water storage heater of capacity 25 Ltrs (04 Nos Nut,Bolts & washer) complete all as specified and directed.
M& L for plug top suitable 15 Amp suitable for (geyser) water storage heater of capacity 25 Ltrs as per existing complete all as specified and directed.
S&F in repair of thermal-cutout with heating sensor rod (capillary type) overload relay/contactor (model T100 20Amp 250 Volts) as per existing sample suitable for 25 litres capacity Geysers, Complete all as specified and directed by Engr-in-charge.
S&F in repair of neon indicator lamp round or rectangular type (ISI marked) , Complete all as specified and directed by Engr-in-charge.
S&F in repair Pressure release safety valve for Geysers spring loaded suitable for 15 mm pipe chromium plated (ISI marked), Complete all as specified and directed by Engr-in-charge.
Supply and fix in repair flexible copper wire PVC insulated, 3 core, 2.5 Sqmm dia multistranded, Complete all as specified and directed by Engr-in-charge.
M&L for replacement of old U/S Chromium plated stainless steel pipe connection for cold water inlet/ hot water outlet pipe of size 15 mm dia complete with nipple/adaptors 450mm long (ISI marked), Complete all as specified and directed by Engr-in-charge.
M&L for replacement of old U/S PVC connection pipe threaded type for cold water inlet/ hot water outlet pipe of size 15 mm dia complete with nipple/adaptors 450mm long (ISI marked) make- prayag/polytuf, Complete all as specified and directed by Engr-in-charge.
S&F in repair SP MCB ranging from 6 to 32 Amp C-Curve type 240 Volt, 50 Hz AC supply with breaking capacity of 10 KA in accordance with IS/ IEC 60898-1 of Make- Polycab/Legrand/ABB/Havells or equivalent make as per PS
S&F in repair SPN MCB ranging from 32 Amp C-Curve type 240 Volt, 50 Hz AC supply with breaking capacity of 10 KA in accordance with IS/ IEC 60898-1 of Make- Polycab/Legrand/ABB/Havells or equivalent make as per PS
M&L for replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp , 10 KA
M & L in replacemnt of sub main wiring with two single core 4.0 Sqmm PVC insulated FR-LSH unsheathed cable multi-stranded copper conductor drawn through and including PVC conduit / PVC casing capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 2.5 Sqmm PVC insulated unsheathed one core multistranded copper conductor earth wire complete all as specified and directed.. Make: Havells/Polycab/RR Kabel/ KEI (Note: Two run of 4 sqmm and one run of 2.5 sqmm earth wire including PVC conduit should be measured & paid as one length)
Less Schedule of Credit
M/S TRADE LINKERS (BID ID -3148291)
R K ENTERPRISES (BID ID -3140738)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .