| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-Finance 01 AGNI AUTOMATION AND SECURITY 01 KUNDAN BHAWAN SHIVAM VIHAR COLONY OPP KIET ENGG COLLEGE MURADNAGAR GHAZIABAD 201206 U P INDIA MURADNAGAR | GHAZIABAD | UTTAR PRADESH | 201206 | ₹24.9 L | L1 | Accepted-Finance ok |
| 2 | L2₹24.9 L+₹1,581.20 (0.06%)Accepted-Finance | ₹24.9 L+₹1,581.20 (0.06%) | L2 | Accepted-Finance ok |
| Sl No | Description | Qty | Unit | AGNI AUTOMATION AND SECURITY L1 | K.L Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Making of all safety arrangements i.e. safety belt, gum boots, helmet, gloves etc. to carry out the work. | 1 | Job | 12,200 ₹14,396 Lowest | 12,370 ₹14,596.6 |
| 2.00 | Dismantling of old liquid rotor starter by opening its incoming and outgoing connection of the motor and opening/cutting the grouted angles nut/bolts etc. | 2 | jobs | 89,600 ₹1,05,728 Lowest | 89,720 ₹1,05,869.6 |
| 3.00 | Shifting of the LRS from the installed location to outside the pump house using Hydra/crane as per requirement & instructions of the Engineer-In-Charge. | 2 | Jobs | 49,600 ₹58,528 Lowest | 49,800 ₹58,764 |
| 4.00 | Supply of the FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 170 KW Motor using Crane/Hydra as per site requirement and as per instructions of Engineer-In-Charge. Make – Innovative/ Any other approved make of DJB. | 1 | No. | 7,54,800 ₹8,90,664 Lowest | 7,55,000 ₹8,90,900 |
| 5.00 | Supply of the FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 220 KW Motor using Crane/Hydra as per site requirement and as per instructions of Engineer-In-Charge. Make – Innovative/ Any other approved make of DJB. | 1 | No. | 8,24,800 ₹9,73,264 Lowest | 8,24,950 ₹9,73,441 |
| 6.00 | Work of installation of FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 170KW/220 KW Motor using Crane/Hydra as per site requirement and as per instructions of Engineer-In-Charge. Make – Innovative/ Any other approved make of DJB. | 2 | Jobs | 2,89,600 ₹3,41,728 Lowest | 2,90,000 ₹3,42,200 |
| 7.00 | Work of connection of the feedback from the main incoming panel and connection of feedback of ACB/MCCB the FCMA panel & Connection of the FCMA rotor controller with required lugs/thimbles /tape etc. to complete the work. | 2 | Jobs | 39,600 ₹46,728 Lowest | 39,700 ₹46,846 |
| 8.00 | Complete testing of the Panel after installation. | 2 | Jobs | 50,000 ₹59,000 Lowest | 50,000 ₹59,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
1 Aug 2026, 2:00 pmClosed
Executive Engineer (EnM)HP II
OFFICE OF THE EXECUTIVE ENGINEER (EnM) HP-II DELHI JAL BOARD GOVT OF NCT OF DELHI HAIDER PUR WATER WORKS, DELHI 110085
S/I/T/C of Soft Starters for already installed Slipring Induction Motors by replacing existing Liquid Rotor Starters at Delhi Cantonment BPS.
2026_DJB_295904_5
NIT 01 (2026-27)/HP-II
Open Tender
Miscellaneous Works
Item Rate
120 days
EE(EnM)HP-II
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB
₹50,000
4 Aug 2026
25 Jul 2026
1 Aug 2026
25 Jul 2026
1 Aug 2026
25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Making of all safety arrangements i.e. safety belt, gum boots, helmet, gloves etc. to carry out the work. | 1 | Job | - | - |
| 2 | Dismantling of old liquid rotor starter by opening its incoming and outgoing connection of the motor and opening/cutting the grouted angles nut/bolts etc. | 2 | jobs | - | - |
| 3 | Shifting of the LRS from the installed location to outside the pump house using Hydra/crane as per requirement & instructions of the Engineer-In-Charge. | 2 | Jobs | - | - |
| 4 | Supply of the FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 170 KW Motor using Crane/Hydra as per site requirement and as per instructions of Engineer-In-Charge. Make – Innovative/ Any other approved make of DJB. | 1 | No. | - | - |
| 5 | Supply of the FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 220 KW Motor using Crane/Hydra as per site requirement and as per instructions of Engineer-In-Charge. Make – Innovative/ Any other approved make of DJB. | 1 | No. | - | - |
| 6 | Work of installation of FCMA based Rotor controller fixed in enclosure with Start/Stop/Run indication and required contactors for operation, having motor protection relay, suitable for 3 Phase 415 Volt supply, motor rating 170KW/220 KW Motor using Crane/Hydra as per site requirement and as per instructions of Engineer-In-Charge. Make – Innovative/ Any other approved make of DJB. | 2 | Jobs | - | - |
| 7 | Work of connection of the feedback from the main incoming panel and connection of feedback of ACB/MCCB the FCMA panel & Connection of the FCMA rotor controller with required lugs/thimbles /tape etc. to complete the work. | 2 | Jobs | - | - |
| 8 | Complete testing of the Panel after installation. | 2 | Jobs | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_393779.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .