| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | ₹46.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹47.7 LRejected-Finance 622 A STREET NO 3 FIRST FLOOR SHAKTI NAGAR BATHINDA 151001 PUNJAB | BATHINDA | PUNJAB | 151001 | ₹47.7 L | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹48.6 LRejected-Finance | ₹48.6 L | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹48.7 LRejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹48.7 L | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹49.0 LRejected-Finance | ₹49.0 L | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | A B K Enterprises L5 | Goyal Enterprises L3 | M/s GANJOO AND CO L7 | UNITED ENGINEERING CORPORATION L4 | M/S Rohit Enterprises L6 | M/S Parshant Associates L1 | M/S ADHIKARI CONSTRUCTION CO. L8 | Truly Technos LLP L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installing, commissioning and testing complete of Manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven Generating Set capable of delivering 100 KVA (80 KW), at 0.8 power factor 107 HP as per latest amendement CPCB-IV+ 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz at power factor minimum power factor of 0.8 lagging. Compact size with manual/automatic starting system, sound proof, weather proof enclosure, low vibration, best in class fuel consumption, class G2 governing in its range, which gives better accuracy in decreasing the speed drop in transient and lowering the recovery time of the speed, confirms to statutory Govt. CPCB-IV+ emission & noise level norms, the enclosure is of modular construction with the provision to assemble and dismantle easily, the sheet metal components are 11 tanks pre-teated and is polyster based powder coated (inside as well as outside) for long life. All nuts, bolts, hardware of of stainless steel for longer life. Battery is provided in a tray inside the enclosure. Doors are gasketed with high quelity EDPN gasket to avoid leakage of sound, a special residential silencer is to be provided to control exhaust noise, specially designed sound attenuators to provide to control sound at air entry and exist points inside the enclosure. System sound to vibration free, engine and alternator are to mounted on specially designed anti-vibration pads mounted on base frame. Adequate ventilation is to be provided to meet the air requirement for combustion and heat removal. | 1 | Each | 19,80,000 ₹19.8 L | 14,97,000 ₹15.0 L | 20,85,000 ₹20.9 L | 16,74,000 ₹16.7 L | 19,99,999 ₹20.0 L | 20,85,000 ₹20.9 L | 19,99,999 ₹20.0 L | 18,20,000 ₹18.2 L |
| 1.01(I) Diesel Engine. Diesel engine 100 KVA, 4 cylinder, three phase liquid cooled, turbo charged developing 107 HP. Electric start, compressed ignition, 4 stroke engine design to run continiously at 1500 RPM. Diesel Genset confirms to present CPCB IV+ norms. The disel engine comprise of following :- (a) Radiator with fan (b) Electric starter motor with self starting system (c) G2 as per ISO 8528 part V class governor (d) Battery charging alternator (e) Dry type air cleaner with service indicator (f) 1 x 12 V DC battery (g) Lube oil and fuel filter (h) First fill of oil and Coolant . The Engine shall be Water cooled 100 KVA, CPCB-IV+, HP-107, oil lubricated, Exhaust silencer, Self seating arrangements and battery charger unit developing 1500 rpm suitable for above output of alternator, capable of taking 10% overloading for 1 hour after 12 hour of continuous operation. The engine shall be fitted complete with all the required accessories like oil type air cleaner, Exhaust silencer suitable for canopy, Expansion bellow,Lube oil cooler,Full flow lube oil filter, Fuel filters (Primary and micron) in-line mono block fuel injection pump, mechanical Governor and fuel feed pump,Flywheel with starter ring and bell housing suitable for close coupling,Exhaust gas driven turbocharger,12 Volt electric starter motor, Battery charging alternator, microprocessor based controller fixed in power panel, Protection system for Low lube oil pressure, High cylinder head temperature, Fuel off solenoid, Initial fill of lube oil, Lube oil drain arrangement,Breather Pipe, AVM's etc complete all as specifiedand directed. | |||||||||||
| 1.02(II) Alternator. Alternator should suitable for continious operation rated at 1500 rpm, 415 volts, 0.80 PF, 50 Hz, Ph. In SPDP enclosure, self excited, self-regulated brush less, floor mouted. The alternator confirms to IS : 4722, BS EN 60034-1 & shall be suitable for tropical conditions. (III) FUEL TANK: in built type fuel tank of capcity 12 Hrs running operation with Fuel gauge air vent and drain plug arrangement with fuel filling cap with Lock & key arrangement is made on the canopy complete all as specified. (IV) BASE FRAME : The base frame shall be Epoxy coated Sheet metal base frame suitable for mounting the Canopy structure directly on the channels.the cross members are designed in such a way that it can house engine and Alternator. Base frame will have provision to mount fuel tank and Battery. End channel will be of removal type for removing the fuel tank etc. Base frame will have provision for Lube oil drain hose and Breather hose. (V) BATTERY and Battery Charger : The Battery of 180 AH 12 volts of quantity recommended by as per OEM specifications with one set of connecting leads of 16 Sqmm size Copper cable as specified by Engineer in charge. The battery charger shall besuitable to charge required number of batteries at 12 Volt/24 volts complete with transformer,rectifier,charge rate selector switch, ammeter, voltmeter, and connections between battery and battery charger shall be provided with suitable size copper cables and lugs. (VI) EXHAUST PIPING : The exhaust piping shall be DG set in complete with Exhaust piping i.e Silencer is mounted and connected by means of MS pipe through flexible pipe to the engine manifold.Entire exhaust piping inside the canopy (cold zone) is insulated by means of ceramicwool and aluminium cladded. | |||||||||||
| 1.03(VII) SPECIFICATION OF CANOPY : (i) Acoustic Enclosure: The Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet . The silent canopy shall be of nut bolt type construction. Critical process of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1mm . Powder coating is done after eleven tank surface preparation process of sheet metal.Canopy panel and doors shall have inside lining of Fire Retardant foam as acoustic material . Four hinged doors shall be provided to canopy one door shall have glass window for control panel along with following connected accessories/ arrangements like Emergency stop button with wiring ,12 Volt Emergency light with wiring,4 nos Slam type Lock with key, 4 Nos lifting hooks,Viewing glass for control panel in the door,Rock wool stuffing in hot air zone,25 mm thickness FTD 32 model foam,3 mm thickness polyurethene cross link tape provided in between top roof and hood,Rain cover plate for Exhaust pipe opening in the roof, All external fasteners used are SS and internal are MS with Green Passivation,Exhaust piping system provided with tail pipe after silencer. (II) Performance Parameters: The average sound level, when measured in green field condition (ISO 3744or 8528 PT 10 ) at 1- meter distance from all four sides shall be less than 75-dBA averages as per CPCB IV+ norms.The average stabilized hot air temperature rise within the canopy is maintained within 10 ºC over and above ambient temperature. | |||||||||||
| 1.04(VIII) AUTOMATIC MAINS FAILURE CONTROL PANEL: M & L for Automatic main failure LT panel factory made indoor type with CRCA sheet of 2 mm thick with by pass arrangement and controls as per manufacture's spcification suitable for DG set cap 100 KVA grouted in floor, PCC Foundation including following accessories and degree of protection shall be IP-42 conforming to IS -2147. (i) MCCB FP 160 Amps 36 KA Adjustable type- 02 Nos (ii) 3 Phase Power contactor of 160 A FP -02 Nos. (iii) Spreader Terminal - 02 Nos, (iv) Rotary Handle - 02 Nos (v) Aux. Contact - 02 Nos (vi) Copper bus bar 200 Amps FP (vii) AMF Controller with RS-485 - 01 No. (viii) Battery Charger - 01 Nos (ix) Multifunction meter with RS-485 - 01 Nos (x) Hooter - 01 Nos (xi) CT for metering 200/5A 15 VA - 03 Nos (xii) Fuses for controlling - 06 Nos (xiii) On delay timer - 03 Nos (xiv) PLA Relay 2C/O 24V DC with base - 03 Nos (xv) DC Ammeter (0-200 A) - 01 Nos (xvi) Indicating lights (Mains ON/DG ON/ Load ON Mins/ Load ON DG Set) - 04 Nos (xvii) Engine Start/Engine Stop Bush button - 02 Nos (xviii) Accept/Reset push button - 02 Nos (xix) A/M selector switch 6 A 2P/2W - 01 Nos (xx) 06A 1P MCB 10 KA 'C' Curve - 08 Nos. (IX) Testing:Testing shall be done complete all as specified and as directed by Testing Officer TO BE NOMINATED BY ACCEPTING OFFICER . The fuel consumption for testing of DG is deemed to be included in the rate quoted. IV) Cost of PCC foundation as per design of OEM is deemed to be included in overall cost quoted : NOTE- (i) COST OF PCC FOUNDATION AS PER DESIGN OF OEM IS INCLUDED IN OVERALL COST QUOTED (ii) Pre- dispach inspection of DG set shall be carried out by the rep of Accepting officer within overall cost quoted | |||||||||||
| 2.00 | Supply, laying, jointing and testing XLPE LT insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 volts grade earthed system and conforming to IS:7098 of 1995 and of size 3.5 core x 150 Sqmm and laid in trenches/ ducts/ pipe or on pole complete all as specified and directed
Note : Rate quoted by the contractor deemed to be inclusive of suitable size of aluminium lugs, thimbles, cable glands, nuts and bolts at cable termination ends irrespective of any span or any length complete all as specified and directed by Engr-in-charge. | 200 | RM | 850 ₹1.7 L | 1,970 ₹3.9 L | 1,040 ₹2.1 L | 960 ₹1.9 L | 1,050 ₹2.1 L | 600 ₹1.2 L | 999 ₹2.0 L | 1,250 ₹2.5 L |
| 3.00 | Supply, laying, jointing and testing XLPE LT insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 volts grade earthed system and conforming to IS:7098 of 1995 and of size 3.5 core x 70 Sqmm and laid in trenches/ ducts/ pipe or on pole complete all as specified and directed
Note : Rate quoted by the contractor deemed to be inclusive of suitable size of aluminium lugs, thimbles, cable glands, nuts and bolts at cable termination ends irrespective of any span or any length complete all as specified and directed by Engr-in-charge) | 110 | RM | 450 ₹49,500 | 1,197 ₹1.3 L | 620 ₹68,200 | 525 ₹57,750 | 500 ₹55,000 | 300 ₹33,000 | 499 ₹54,890 | 760 ₹83,600 |
| 4.00 | Fabricate, Supply install test and commissioning in replacement of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators as indicated on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (Main panel)
(a) Bus bar Aluminium - 500 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 250 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No.
(c) MCCB 125 Amps 3 pole 25 KA with adjustable thermal range as out going- 01 Nos for Lawn panel
(d) MCCB 100 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 02 Nos.
(e) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 05 Nos.
(f) MCB TP 63 Amps, 10 KA, 'C Series -04 Nos
(g) MCB SPN 40 Amps, 10 KA, 'B' Series -04 Nos
(h) Digital multifuctional meter (Make : L&T) 4410 Series, Cat No. WL441010OOOO - 01 Nos
(j) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 09 Set of three | 1 | Each Job | 2,25,000 ₹2.3 L | 1,80,600 ₹1.8 L | 1,99,000 ₹2.0 L | 2,10,000 ₹2.1 L | 2,10,000 ₹2.1 L | 1,75,000 ₹1.8 L | 1,49,999 ₹1.5 L | 2,15,000 ₹2.1 L |
| 5.00 | Fabricate, Supply install test and commissioning in replacement of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators as indicated on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (Main panel)
(a) Bus bar Aluminium - 250 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves.
(b) MCCB 125 Amps 4 pole 25 KA with adjustable thermal range as out going- 01 Nos for Lawn panel
(c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 02 Nos.
(d) MCB TP 63 Amps, 10 KA, 'C Series -06 Nos
(e) MCB SPN 40 Amps, 10 KA, 'B' Series -10 Nos
(f) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 01 Set of three | 1 | Each Job | 1,00,000 ₹1 L | 99,000 ₹99,000 | 99,000 ₹99,000 | 1,20,000 ₹1.2 L | 1,00,000 ₹1 L | 1,10,000 ₹1.1 L | 99,999 ₹99,999 | 1,18,000 ₹1.2 L |
| 6.00 | Cutting existing road surfaces or hard standing 0.45 mtr depth and 0.3 mtr width (22 CM thick comprising bituminous topping) for laying of pipes/cables and making good to the disturbed surfaces to match with existing complete all as specified and directed. Note : Rate quoted by the contractor deemed to be inclusive of PCC 1:2:4 to be required to making good the disturbed surface to match with existing. | 20 | RM | 450 ₹9,000 | 157 ₹3,140 | 200 ₹4,000 | 500 ₹10,000 | 500 ₹10,000 | 500 ₹10,000 | 499 ₹9,980 | 3,000 ₹60,000 |
Updated dates
Tender Value
₹57.5 L
EMD Value
₹1.1 L
Closing Date
28 Nov 2025, 6:00 pmClosed
Col L Suvarna CWE
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
PROVN OF STANDBY POWER SUPPLY TO PERIMETER LIGHTS, SPECIAL REPAIR/ REPLACEMENT OF BER AIR CONDITIONERS AND PROVN OF AIR CONDITIONING AT CERTAIN BUILDINGS AT AF STN ARJANGARH IN AOR OF GE (AF) GURGAON
2025_MES_735751_1
CWE/GGN/GT-28/2025-26
Open Tender
Electrical and Maintenance Works
180 days
AF Stn Arjangarh
As per NIT
8 documents required · 8 mandatory
₹1,000
GE AF Gurgaon
₹1.1 L
Yes
22 Jan 2026
17 Oct 2025
1 Dec 2025
17 Oct 2025
28 Nov 2025
8 Nov 2025
17 Oct 2025 - 7 Nov 2025
Amount
Supply, installing, commissioning and testing complete of Manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven Generating Set capable of delivering 100 KVA (80 KW), at 0.8 power factor 107 HP as per latest amendement CPCB-IV+ 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz at power factor minimum power factor of 0.8 lagging. Compact size with manual/automatic starting system, sound proof, weather proof enclosure, low vibration, best in class fuel consumption, class G2 governing in its range, which gives better accuracy in decreasing the speed drop in transient and lowering the recovery time of the speed, confirms to statutory Govt. CPCB-IV+ emission & noise level norms, the enclosure is of modular construction with the provision to assemble and dismantle easily, the sheet metal components are 11 tanks pre-teated and is polyster based powder coated (inside as well as outside) for long life. All nuts, bolts, hardware of of stainless steel for longer life. Battery is provided in a tray inside the enclosure. Doors are gasketed with high quelity EDPN gasket to avoid leakage of sound, a special residential silencer is to be provided to control exhaust noise, specially designed sound attenuators to provide to control sound at air entry and exist points inside the enclosure. System sound to vibration free, engine and alternator are to mounted on specially designed anti-vibration pads mounted on base frame. Adequate ventilation is to be provided to meet the air requirement for combustion and heat removal.
(I) Diesel Engine. Diesel engine 100 KVA, 4 cylinder, three phase liquid cooled, turbo charged developing 107 HP. Electric start, compressed ignition, 4 stroke engine design to run continiously at 1500 RPM. Diesel Genset confirms to present CPCB IV+ norms. The disel engine comprise of following :- (a) Radiator with fan (b) Electric starter motor with self starting system (c) G2 as per ISO 8528 part V class governor (d) Battery charging alternator (e) Dry type air cleaner with service indicator (f) 1 x 12 V DC battery (g) Lube oil and fuel filter (h) First fill of oil and Coolant . The Engine shall be Water cooled 100 KVA, CPCB-IV+, HP-107, oil lubricated, Exhaust silencer, Self seating arrangements and battery charger unit developing 1500 rpm suitable for above output of alternator, capable of taking 10% overloading for 1 hour after 12 hour of continuous operation. The engine shall be fitted complete with all the required accessories like oil type air cleaner, Exhaust silencer suitable for canopy, Expansion bellow,Lube oil cooler,Full flow lube oil filter, Fuel filters (Primary and micron) in-line mono block fuel injection pump, mechanical Governor and fuel feed pump,Flywheel with starter ring and bell housing suitable for close coupling,Exhaust gas driven turbocharger,12 Volt electric starter motor, Battery charging alternator, microprocessor based controller fixed in power panel, Protection system for Low lube oil pressure, High cylinder head temperature, Fuel off solenoid, Initial fill of lube oil, Lube oil drain arrangement,Breather Pipe, AVM's etc complete all as specifiedand directed.
(VII) SPECIFICATION OF CANOPY : (i) Acoustic Enclosure: The Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet . The silent canopy shall be of nut bolt type construction. Critical process of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1mm . Powder coating is done after eleven tank surface preparation process of sheet metal.Canopy panel and doors shall have inside lining of Fire Retardant foam as acoustic material . Four hinged doors shall be provided to canopy one door shall have glass window for control panel along with following connected accessories/ arrangements like Emergency stop button with wiring ,12 Volt Emergency light with wiring,4 nos Slam type Lock with key, 4 Nos lifting hooks,Viewing glass for control panel in the door,Rock wool stuffing in hot air zone,25 mm thickness FTD 32 model foam,3 mm thickness polyurethene cross link tape provided in between top roof and hood,Rain cover plate for Exhaust pipe opening in the roof, All external fasteners used are SS and internal are MS with Green Passivation,Exhaust piping system provided with tail pipe after silencer. (II) Performance Parameters: The average sound level, when measured in green field condition (ISO 3744or 8528 PT 10 ) at 1- meter distance from all four sides shall be less than 75-dBA averages as per CPCB IV+ norms.The average stabilized hot air temperature rise within the canopy is maintained within 10 ºC over and above ambient temperature.
Supply, laying, jointing and testing XLPE LT insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 volts grade earthed system and conforming to IS:7098 of 1995 and of size 3.5 core x 150 Sqmm and laid in trenches/ ducts/ pipe or on pole complete all as specified and directed Note : Rate quoted by the contractor deemed to be inclusive of suitable size of aluminium lugs, thimbles, cable glands, nuts and bolts at cable termination ends irrespective of any span or any length complete all as specified and directed by Engr-in-charge.
Supply, laying, jointing and testing XLPE LT insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 volts grade earthed system and conforming to IS:7098 of 1995 and of size 3.5 core x 70 Sqmm and laid in trenches/ ducts/ pipe or on pole complete all as specified and directed Note : Rate quoted by the contractor deemed to be inclusive of suitable size of aluminium lugs, thimbles, cable glands, nuts and bolts at cable termination ends irrespective of any span or any length complete all as specified and directed by Engr-in-charge)
Fabricate, Supply install test and commissioning in replacement of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators as indicated on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (Main panel) (a) Bus bar Aluminium - 500 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. (b) MCCB 250 Amps 4 pole 36 KA, with adjustable thermal magnetic range as in coming - 01 No. (c) MCCB 125 Amps 3 pole 25 KA with adjustable thermal range as out going- 01 Nos for Lawn panel (d) MCCB 100 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 02 Nos. (e) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 05 Nos. (f) MCB TP 63 Amps, 10 KA, 'C Series -04 Nos (g) MCB SPN 40 Amps, 10 KA, 'B' Series -04 Nos (h) Digital multifuctional meter (Make : L&T) 4410 Series, Cat No. WL441010OOOO - 01 Nos (j) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 09 Set of three
Fabricate, Supply install test and commissioning in replacement of CPRI approved Outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 3.15 mm thick CRCA sheet load bearing members and load bearing members such as door partitions etc of thick no less than 2.0 mm thick , with gland paltes at bottom with suitable Brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators as indicated on incoming side and ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCB's with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection,including terminal adapters, spreader links on incoming and out going sides of MCCB's complete all as specified and directed and comprising of the following (Main panel) (a) Bus bar Aluminium - 250 A capacity- 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. (b) MCCB 125 Amps 4 pole 25 KA with adjustable thermal range as out going- 01 Nos for Lawn panel (c) MCCB 63 Amps 3 pole 16 KA with adjustable thermal magnetic range as out going- 02 Nos. (d) MCB TP 63 Amps, 10 KA, 'C Series -06 Nos (e) MCB SPN 40 Amps, 10 KA, 'B' Series -10 Nos (f) ON/OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 01 Set of three
Cutting existing road surfaces or hard standing 0.45 mtr depth and 0.3 mtr width (22 CM thick comprising bituminous topping) for laying of pipes/cables and making good to the disturbed surfaces to match with existing complete all as specified and directed. Note : Rate quoted by the contractor deemed to be inclusive of PCC 1:2:4 to be required to making good the disturbed surface to match with existing.
M & L for GI tubing (light grade) with all necessary fitting laid in trenches/under road crossing, or fixed on poles/walls/under floor etc complete all as specified and as directed for the following sizes:-
50 mm dia bore
80 mm dia bore
Excavation in trenches in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for pipes and getting out complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
M&L for sand cushning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed. Note : Sand Compacted thickness 18cm shall be considered for measurement and payment purpose.
Supply and lay well burnt brick class B as protection to cable in cable trenches all as specified and directed
Supply and installation of refrigerator, electric driven (single phase), capacity 322 ltrs, 3 star frost free smart invertor compressor double door multi air flow cooling , complete.
Supply and installation of refrigerator, electric driven (single phase), capacity 242 ltrs, 3 star frost free smart invertor compressor double door multi air flow cooling complete.
Supply and installation of refrigerator, electric driven (single phase), capacity 192 ltrs, 3 star invertor direct cooled single door Auto defrost technology, 2023 Model stabilizer free operation.
Supply , installation, commissioning of water cooler fully stainless steel electric driven (single phase) having approx storage capacity 80 Ltrs and nominal cooling capacity 40 Ltrs per hour.
Supply , installation, commissioning of water cooler fully stainless steel electric driven (single phase) having approx storage capacity 120 Ltrs and nominal cooling capacity 60 Ltrs per hour.
Supply & installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V accuracy of 2.5 % and capacity of size 5 KVA.
Supply and fixing of desert cooler having heavy duty Fan of metal body, including 450mm sweep, 1500 RPM, 240 Volts, single phase fan motor and submersible water pump of best quality for 2 m head, body of cooler fabricated out of GI sheet of not less than 1.20mm thick, including 5m, 3 core flexible cord with plug top 5/15 Amp, 3 pin, electric driven having nominal air flow capacity of 4000 Cum/hour complete all as specified and as directed.
Supply and install hi wall split Type Airconditioner with indoor & outdoor (copper condensor) unit single phase electric driven complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser, PM 2.5 Filter for better indoor air quality with minimum 5 star rating of capacity 2 TR with precharged CFC free (R32/R410A) refrigerant all as specified and directed by Engr-in-Charge. Note Outdoor stand with anchor fastner is included in the item rates.
Supply and install hi wall split Type Airconditioner with indoor & outdoor (copper condensor) unit single phase electric driven complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser, PM 2.5 Filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR with precharged CFC free (R32/R410A) refrigerant all as specified and directed by Engr-in-Charge. Note Outdoor stand with anchor fastner is included in the item rates.
M&L for sub main wiring with two runs of 6.0 Sqmm 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 and drawn through non metallic PVC conduit of size not less than 25mm dia ISI marked with one run of 6.0 Sqmm single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and eath dolly in conduit incl connecting to main panel complete all as specified and directed. Note : Two run of 6.0 sqmm copper conductor and one run of 6.0 sqmm earthing wire and OVC conduit with conduit accessories shall be considered and measured as one unit length.
S&F drain pipes 25 mm dia heavy duty rigid PVC from indoor unit to exist point as per design including accessories clamps fastner complete all as specified and directed.
S&F additional copper tubing 5/8" with rubber insulation unit suitable for 2 TR Split AC all as specified and directed .
S&F additional copper tubing 1/4" with rubber insulation unit suitable for 1.5 TR Split AC all as specified and directed.
S&F additional copper tubing 1/2" with rubber insulation unit suitable for 1.5 TR Split AC all as specified and directed.
S&F additional copper cable 4 core 2.5 sqmm suitable for 1.5/2 TR Split AC all as specified and directed.
S&F MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, all as specified.
M&L for fabrication of Air conditioner outdoor unit shed cover canopy type made of hollo MS square pipe of sizes 25x25x2mm including welding with top GI sheet not less than of 0.7mm thick (Japani sheet) including welding grouting on PCC platform with nuts bolts detachable type all as specified and directed
M&L for cement concrete in foundation concrete type C1 (1:3:6) mix with 20 mm graded stone aggregate to serve as thrust block for water pipe line complete all as specified and directed. Note :- Pipe line will be required to be laid in trench or above ground as per site requirement in full length or part length, pipe line is passing through jungle area, hill, nala etc. Note lighting arrangement required is included in item rates.
M&L for stickers/ radium strips printing (6.50cmx2.5cm) for air conditioners/voltage stabilizers on front face with SM/MES Numbers incl preparation of surface complete all as specified and directed
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20-32 Amps complete all as specified and directed.
Supply & installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V accuracy of 2.5 % and capacity of size 5 KVA complete all as specified and dirceted.
Supply & installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V accuracy of 2.5 % and capacity of size 4 KVA complete all as specified and dirceted.
S&F additional copper cable 3 core 2.5 sqmm suitable for 1.5/2 TR Split AC all as specified and directed by Engineer in Charge.
Net Contract Sum will be after deducting Sch of Credit of Rs 4000.00
Truly Technos LLP (BID ID -3479472)
Goyal Enterprises (BID ID -3474637)
UNITED ENGINEERING CORPORATION (BID ID -3483058)
A B K Enterprises (BID ID -3473586)
M/S Rohit Enterprises (BID ID -3485157)
M/s GANJOO AND CO (BID ID -3479185)
M/S ADHIKARI CONSTRUCTION CO. (BID ID -3471423)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_823876.xls
BOQ • 1.02 MB
TDGT28.pdf
Tender Documents • 1.24 MB
Download all tender documents and submit your bid