Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹30 L
Closing Date
15 Oct 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
PR & CC
Construction of LPG sheds at Sitarganj LPG Plant
20000480-HD-10157
20000480-HD-10157
Open Tender
Two Bid
Unknown (Unspecified Location)
₹0
₹30 L
15 Oct 2020
25 Sept 2020
15 Oct 2020
15 Oct 2020
26 Sept 2020 - 5 Oct 2020
7 Oct 2020
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | Excavation in soil 0-1.5 | Excavation in soil 0-1.5 — SHED WORK/CIVIL, LPG PROJECTS: EXCAVATION IN ORDINARY SOIL 0-1.5 METER: EXCAVATION FOR FOOTINGS, PLINTH BEAMS, FOUNDATIONS, PEDESTALS, CULVERTS, PITS, TRENCHES, ROADS ETC. AS DIRECTED, IN ALL SOILS INCLUDING SOFT ROCK AND DIS-INTEGRATED ROCK BUT EXCLUDING HARD ROCK TO A DEPTH OF 1.5 M BELOW EXISTING GROUND LEVEL AND INCLUDING STACKING WITHIN PLOT BOUNDARY, SHORING AND STRUTTING IF ANY REQUIRED; TAKING SPOT LEVELS ON EDGES AND CENTERLINE AT 3 TO 5M C/C AS PER SPECIFICATIONS; BAILING OUT OF WATER IF ENCOUNTERED (UNTIL FOUNDATION WORK IS COMPLETE); PROVIDING TEMPORARY SUPPORTS IF REQUIRED. JOB INCLUDES BACKFILLING OF EXCAVATED EARTH IN SUB-STRUCTURE TO PROPER GRADE AND LEVEL WHICH IS EXCAVATED AND STACKED EARLIER WITHIN THE PLANT BOUNDARY, INCLUDING RE-EXCAVATING THE DEPOSITED SOIL EXCAVATED EARLIER, BREAKING CLODS, LAYING AT ALL DEPTHS AND HEIGHTS IN LAYERS OF THICKNESS NOT EXCEEDING 200 MM LOOSE THICKNESS, WATERING, ROLLING AND RAMMING BY MANUAL METHODS/MECHANICAL COMPACTORS TO ACHIEVE 95% LABORATORY MAXIMUM DRY DENSITY, DRESSING, TRIMMING ETC. IN FOUNDATIONS, PLINTHS, TRENCHES, PITS ETC. ALL COMPLETE. THE REMAINING EXCESSIVE EARTH IS TO BE CARTED AWAY, DISPOSED, LEVELED AND COMPACTED TO 95% DRY DENSITY TO ANY OTHER LOCATION WITHIN PLANT BOUNDARIES ALL COMPETE AS PER INSTRUCTIONS OF HPCL. | - | Cubic Meters |
| 2 | Excavation in soil 1.5-3.0 | Excavation in soil 1.5-3.0 — SHED WORK/CIVIL, LPG PROJECTS: EXCAVATION IN ORDINARY SOIL 1.5 TO 3 METER: EXCAVATION FOR FOOTINGS, PLINTH BEAMS, FOUNDATIONS, PEDESTALS, CULVERTS, PITS, TRENCHES, ROADS ETC. AS DIRECTED, IN ALL SOILS INCLUDING SOFT ROCK AND DIS-INTEGRATED ROCK BUT EXCLUDING HARD ROCK TO A DEPTH FROM 1.5 TO 3.0 METER BELOW EXISTING GROUND LEVEL AND INCLUDING STACKING WITHIN PLOT BOUNDARY, SHORING AND STRUTTING IF ANY REQUIRED; TAKING SPOT LEVELS ON EDGES AND CENTERLINE AT 3 TO 5 METER C/C AS PER SPECIFICATIONS; BAILING OUT OF WATER IF ENCOUNTERED (UNTIL FOUNDATION WORK IS COMPLETE); PROVIDING TEMPORARY SUPPORTS IF REQUIRED. JOB INCLUDES BACKFILLING OF EXCAVATED EARTH IN SUB-STRUCTURE TO PROPER GRADE AND LEVEL WHICH IS EXCAVATED AND STACKED EARLIER WITHIN THE PLANT BOUNDARY, INCLUDING RE-EXCAVATING THE DEPOSITED SOIL EXCAVATED EARLIER, BREAKING CLODS, LAYING AT ALL DEPTHS AND HEIGHTS IN LAYERS OF THICKNESS NOT EXCEEDING 200 MM LOOSE THICKNESS, WATERING, ROLLING AND RAMMING BY MANUAL METHODS/MECHANICAL COMPACTORS TO ACHIEVE 95% LABORATORY MAXIMUM DRY DENSITY, DRESSING, TRIMMING ETC. IN FOUNDATIONS, PLINTHS, TRENCHES, PITS ETC. ALL COMPLETE. THE REMAINING EXCESSIVE EARTH IS TO BE CARTED AWAY, DISPOSED, LEVELED AND COMPACTED TO 95% DRY DENSITY TO ANY OTHER LOCATION WITHIN PLANT BOUNDARIES ALL COMPETE AS PER INSTRUCTIONS OF HPCL. | - | Cubic Meters |
| 3 | Anti-termite treatment | Anti-termite treatment — SHED WORK/CIVIL, LPG PROJECTS, ANTI-TERMITE TREATMENT: SUPPLYING AND INJECTING WITH APPROVED QUALITY CHEMICAL EMULSION AT THE RATES AND CONCENTRATIONS AS PER IS 6313-1981 PART II FOR PRE CONSTRUCTIONAL ANTI TERMITE TREATMENT AND CREATING A CHEMICAL BARRIER UNDER AND ALL ROUND THE COLUMN PITS, FOUNDATION, WALL TRENCHES, PLINTH FILLING, JUNCTIONS OF WALL AND FLOOR, EXPANSION JOINTS, APRON, SURROUNDING OF PIPES, CONDUITS ETC., ALONG THE PERIMETER OF THE BUILDING/SHED INCLUDING ALL BYE WORKS COMPLETE AS PER SPECIFICATION AND DIRECTION OF ENGINEER (ONLY GROUND FLOOR PLINTH AREA OF THE BUILDING WILL BE MEASURED FOR THE PAYMENT. WORK TO BE EXECUTED BY M/S PEST CONTROL (INDIA) OR ANY OTHER APPROVED AGENCY AND SPECIFIED GUARANTEE FOR 10 (TEN) YEARS SHALL BE FURNISHED BY THE BIDDER. THE ANTI-TERMITE TREATMENT SHALL BE PROVIDED AS PER BIS 6313 (PART-2)-LATEST REVISION. THE CHEMICALS USED SHALL BE ANY ONE OR COMBINATION OF THE FOLLOWING WITH CONCENTRATION SHOWN AGAINST EACH IN AQUEOUS EMULSION: CHEMICALS CONCENTRATION: CHLOROPYRIFOS (20% EC) 1% BY WT (IS:8944-LATEST REV), LINDALE (20% EC)-1% BY WT (IS:632 LATEST REV) OR IMIDACLOPRID (30.5% SC).IN CASE LINDALE IS BANNED, SAME SHALL NOT BE USED. THE VARIOUS STEPS AND RATES OF APPLICATION GIVEN IN IS:6313 (PART-2) SHALL BE FOLLOWED. | - | Square Meters |
| 4 | Earth filling upto floor level | Earth filling upto floor level — EARTH FILLING UP TO FLOOR LEVEL, SHED WORK/CIVIL, LPG PROJECTS: SUPPLYING AND FILLING OF EARTH/SOIL OF APPROVED QUALITY WITH PI OF 1 TO 7 (LOW PLASTIC) OR 7 TO 17 (MEDIUM PLASTIC) CONTAINING NOT MORE THAN 20% COHESIVE FINES NAMELY CLAY, 40 MM AND DOWN SIZE GRADING AND MAXIMUM DRY DENSITY OF MATERIAL NOT LESS THAN 1.70 GMS/CC, INCLUDING EXCAVATION AT BORROW PITS OUTSIDE PLANT PREMISES; PAYMENT OF ROYALTY TO OWNER OF BORROW PIT, IF APPLICABLE; PAYMENT OF APPLICABLE ROYALTIES, TAXES, ETC TO STATUTORY AUTHORITY FOR OPERATING THE BORROW PIT; LOADING AT BORROW PIT END; TRANSPORTATION FROM BORROW PIT TO HPCL PREMISES; REMOVING DEBRIS, ORGANIC MATTER, ETC; SPREADING IN LAYERS NOT EXCEEDING 200MM LOOSE DEPTH; DEWATERING DURING COURSE OF FILLING, WATERING, COMPACTION WITH VIBRO-COMPACTOR TO OBTAIN 95% OF STANDARD PROCTOR MAXIMUM LABORATORY DRY DENSITY AND FINISHING TO SLOPES AND GRADES AS PER DRAWINGS ALL COMPLETE AS PER SPECIFICATIONS AND INSTRUCTIONS OF HPCL ENGINEER-IN-CHARGE. RATE SHALL BE APPLICABLE FOR ALL DEPTHS BELOW FFL. QUOTED RATES ARE DEEMED TO INCLUDE PROVIDING DEWATERING PUMP FOR DEWATERING IF REQUIRED; CONDUCTING INITIAL LABORATORY TESTS ON SAMPLES AND SUBSEQUENT IN SITU DRY DENSITY/OMC TEST SAT 500 SQUARE METER OF AREA AFTER EACH LAYER OF FILLING ALL COMPLETE. CONTRACTOR SHALL PLAN FOR SUPPLY OF MURRUM AFTER CHECKING THE APPROX. VOLUME OF SERVICEABLE EARTH AVAILABLE FOR BACKFILLING IN CONSULTATION WITH HPCL. | - | Cubic Meters |
| 5 | PCC 1:3:6 below floor | PCC 1:3:6 below floor — PCC 1:3:6 BELOW FLOOR, SHED WORK/CIVIL, LPG PROJECTS: PCC 1:3:6: PROVIDING AND LAYING IN POSITION PLAIN CEMENT CONCRETE UNDER FOUNDATIONS, PLINTH BEAM, FLOORS, DRAINS, ETC. AS SPECIFIED IN ANY SHAPE, LEVEL, THICKNESS, POSITION AND FINISHING THE TOP SURFACE SMOOTH ETC. ALL COMPLETE AS DIRECTED BY HPCL EIC, INCLUDING THE COST OF CENTERING AND SHUTTERING, TAMPING, RAMMING, CURING, ETC-ALL WORK UP TO PLINTH LEVEL. PCC SHALL BE OF NOMINAL VOLUMETRIC MIX 1:3:6 (1 CEMENT: 3 COARSE SAND: 6 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE). | - | Cubic Meters |
| 6 | PCC 1:4:8 below foundation | PCC 1:4:8 below foundation — PCC 1:4:8 BELOW FOUNDATION, SHED WORK/CIVIL, LPG PROJECTS: PCC 1:4:8: PROVIDING AND LAYING IN POSITION PLAIN CEMENT CONCRETE UNDER FOUNDATIONS, PLINTH BEAM, FLOORS, DRAINS, ETC. AS SPECIFIED IN ANY SHAPE, LEVEL, THICKNESS, POSITION AND FINISHING THE TOP SURFACE SMOOTH ETC. ALL COMPLETE AS DIRECTED BY HPCL EIC, INCLUDING THE COST OF CENTERING AND SHUTTERING, TAMPING, RAMMING, CURING, ETC-ALL WORK UP TO PLINTH LEVEL. PCC SHALL BE OF NOMINAL VOLUMETRIC MIX 1:4:8 (1 CEMENT: 4 COARSE SAND: 8 GRADED STONE AGGREGATE 40 MM NOMINAL SIZE). | - | Cubic Meters |
| 7 | RCC M15 Plinth protection | RCC M15 Plinth protection — RCC M15 PLINTH PROTECTION, SHED WORK/CIVIL, LPG PROJECTS: PCC/RCC M 15: SUPPLYING AND LAYING WITH DESIGN MIX, REINFORCED CEMENT CONCRETE OF GRADE M-15 (EXCLUDING SHUTTERING AND REINFORCEMENT) AT ALL DEPTHS AND HEIGHTS IN ALL TYPES OF FOUNDATIONS, FOOTINGS, EQUIPMENT FOUNDATIONS, COLUMNS, PEDESTAL, WALL, LINTELS, PLINTH BEAMS, BRACKETS, SILLS, PARAPETS, BANDS, PLINTH PROTECTION AND ANY OTHER WORKS ALL COMPLETE AS PER DRAWINGS, SPECIFICATION AND INSTRUCTION OF ENGINEER EIC. FOR DESIGN MIX, MODERATE EXPOSURE SHALL BE CONSIDERED. DESIGN MIX SHALL BE AS PER IS:456-2000 AND IS: 10262 AND SAME SHALL BE DESIGNED BY A LAB/AGENCY/INSTITUTION APPROVED BY HPCL. RMC WILL BE PERMITTED BASED ON PRIOR INSPECTION BY HPCL. CEMENT OF TENDER APPROVED MAKE ONLY SHALL BE PERMITTED. | - | Cubic Meters |
| 8 | RCC M20 Flooring | RCC M20 Flooring — RCC M20 FLOORING, SHED WORK/CIVIL, LPG PROJECTS: RCC M20: SUPPLYING READY MIXED CONCRETE WITH WELL GRADED STONE CHIPS OF 20 MM NOMINAL SIZE CONTAINING DESIGNED QUANTITY OF CEMENT PER CU.M OF WET CONCRETE PRODUCED IN COMPUTERIZED BATCHING PLANT UNDER CONTROLLED CONDITION USING APPROVED SUPER PLASTICIZER, DESIGNING CONCRETE MIX FOLLOWING I.S. 10262 AND I.S. 456, MINIMUM CEMENT CONTENT, W/C RATIO AS PER IS 456, MODERATE EXPOSURE AND STANDARD GENERAL NOTES OF DRAWING, INCLUDING EPOXY BONDING AGENT AS REQUIRED ON CONCRETE SURFACE AS SPECIFIED, TRANSPORTING THE MIX WITH AGITATION IN TRANSIT MIXER TO WORK SITE DEPOSITING THE MIX ON A PLATFORM ERECTED FOR THE PURPOSE AT REQUIRED LEVELS OF CONCRETING AND THEN PLACING THE MIX IN ITS FINAL LOCATION OF FORM WORK, COMPACTING AND CURING THE SAME COMPLETE AS PER SPECIFICATION AND DIRECTION OF THE ENGINEER-IN-CHARGE INCLUDING COMPUTERIZED BATCHING PLANT TRANSIT MIXER WITH ALL ACCESSORIES, VIBRATORS ETC. INCLUSIVE OF ALL OTHER INCIDENTAL CHARGES IN THIS CONNECTION (EXCLUDING THE COST OF REINFORCEMENT AND SHUTTERING) IN FOUNDATION, TRENCHES, PILE CAPS, PITS, GRADE SLABS, SUPERSTRUCTURE ETC. CONCRETE FOR GRADE SLAB M20 WITH WELL GRADED STONE CHIPS OF 20 MM NOMINAL SIZE. | - | Cubic Meters |
| 9 | RCC M25 below ground | RCC M25 below ground — RCC M25 BELOW GROUND, SHED WORK/CIVIL, LPG PROJECTS: RCC M25 BELOW GROUND: SUPPLYING AND PROVIDING OF DESIGN MIX, REINFORCED CEMENT CONCRETE OF M25 GRADE WITH WELL GRADED STONE CHIPS OF 20 MM NOMINAL SIZE (EXCLUDING SHUTTERING AND REINFORCEMENT) FOR BELOW GROUND CONCRETE FOR FOUNDATION, TRENCHES, PILE CAPS, PITS, GRADE SLABS, ETC. AND ANY OTHER WORKS ALL COMPLETE AS PER DRAWINGS, SPECIFICATION AND INSTRUCTION OF ENGINEER. FOR DESIGN MIX, MODERATE EXPOSURE SHALL BE CONSIDERED AND WATER CEMENT RATIO SHALL BE LIMITED TO 0.5. DESIGN MIX SHALL BE AS PER IS:456-2000 AND IS: 10262 AND SAME SHALL BE CARRIED OUT BY A LAB/AGENCY/INSTITUTION APPROVED BY HPCL.RMC WILL BE PERMITTED BASED ON PRIOR INSPECTION BY HPCL. MINIMUM CEMENT CONTENT SHALL BE 350 KG/M3 FOR M-25 GRADE CONCRETE. | - | Cubic Meters |
| 10 | RCC M25 above ground | RCC M25 above ground — RCC M25 ABOVE GROUND, SHED WORK/CIVIL, LPG PROJECTS: RCC M25 ABOVE GROUND: SUPPLYING AND PROVIDING OF DESIGN MIX, REINFORCED CEMENT CONCRETE OF M25 GRADE WITH WELL GRADED STONE CHIPS OF 20 MM NOMINAL SIZE (EXCLUDING SHUTTERING AND REINFORCEMENT) FOR ABOVE GROUND CONCRETE FOR BEAMS/COLUMNS/PEDESTALS/ SLABS AND ANY OTHER WORKS ALL COMPLETE AS PER DRAWINGS, SPECIFICATION AND INSTRUCTION OF ENGINEER. FOR DESIGN MIX, MODERATE EXPOSURE SHALL BE CONSIDERED AND WATER CEMENT RATIO SHALL BE LIMITED TO 0.5. DESIGN MIX SHALL BE AS PER IS:456-2000 AND IS: 10262 AND SAME SHALL BE CARRIED OUT BY A LAB/AGENCY/INSTITUTION APPROVED BY HPCL.RMC WILL BE PERMITTED BASED ON PRIOR INSPECTION BY HPCL. MINIMUM CEMENT CONTENT SHALL BE 350 KG/M3 FOR M-25 GRADE CONCRETE. | - | Cubic Meters |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
20000480-HD-10157.pdf
TENDER_DOCUMENT • 24.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .