Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.9 L+₹62,811.30 (3.86%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹17.5 L+₹1.3 L (7.71%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹17.9 L+₹1.6 L (9.83%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹18.0 L+₹1.7 L (10.7%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹17.8 L
EMD Value
₹35,600
Closing Date
28 Jan 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
PROVN OF PCC ROAD FROM GATE NO 1 TO GATE NO 2 IN SOUTH CAMP AT KHANPUR AND PROVN OF 02 X SENTRY POST FOR DSC GUARDS AT DGIS AND PROVISION OF COPPER WIRING AND FIXTURES AND CONNECTED ACCESSORIES AT P 80D OFFRS MD ACCN OF GE (SOUTH) DELHI CANTT 10
2020_MES_312499_1
GE/DS-68/2019-20
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹35,600
Yes
24 Feb 2020
7 Jan 2020
31 Jan 2020
7 Jan 2020
28 Jan 2020
21 Jan 2020
8 Jan 2020 - 18 Jan 2020
Amount
B/R Works:- Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes & sewage lines, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
M&L for hardcore of broken stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in mass concrete.
M&L for brickwork with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) complete all as specified and as directed by the Engineer-in-Charge.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, as roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate in chajjas complete all as specified and as directed by the Engineer-in-Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15mm thick in Cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 15mm thick in Cement mortar 1:3 on ceilings, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75mm thick cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base to floor finished rough to receive finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L for joint free Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-Charge.
All same as per item No. 15 here in before but on skirting.
M&L for 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
M&L for mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on plastered surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of cement primer complete all as specified and as directed by the Engineer-in-Charge.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric(wt. not less than 150 gms/sqm) laid on primed surface including primer by forced application by using Butane torch and sealing all joints with 100mm of side laps and 150mm at end laps minimium complete all as specified and as directed by the Engineer-in-Charge.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per Sqm roof/wall surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L for 75mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggt) as in sub base of floor etc finished surface fair & even complete all as specified and as directed by the Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed by the Engineer-in-Charge.
M&L for rolling of forming surface over cutting/filling earth with 8 to 10 ton power roller complete all as specified and as directed by the Engineer-in-Charge.
M&L for soling 150mm thick (Compacted thickness) with crushed/broken stone metal (Quartzite) graded from 100 to 50mm intersectices filled, surface framed and rolled consolidated to required camber & gradient complete all as specified and as directed by the Engineer-in-Charge.
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) as in sub floor complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm (except sand) under floor complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material i.e soil exc. 250m but n.exc 500m amd depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L for cement concrete (Design Mix) work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using minimum 400 kg of cement per cubic metre using metallic hardener at the rate of 5.00 Kg/Sqm complete all as specified and directed by the Engineer-in-Charge. Note:- Metallic hardener shall be measured and paid for separately.
Supply only metallic hardener Make:- Sikka/ Nitoflor
M&L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'B' complete all as specified and as directed by the Engineer-in-Charge.
M&L for forming contraction (Dummy) joints 65mm deepx10 mm wide, filled with sealing compound grade 'B' complete all as specified and as directed by the Engineer-in-Charge.
M&L for finishing surface to concrete roads, pavements, by brooming complete all as specified and as directed by the Engineer-in-Charge.
E/M Works M&L for sub main wiring complete multistrand copper conductor cable 2 runs of 6 Sq mm for phase and neutral and 1 run of 4 Sqmm for earth wire drawn through existing concealed steel/PVC conduit wiring in wall not less than 25 mm dia with all fittings like tees, bends, junction/terminal boxes etc as per site requirement complete all as specified and as directed by the Engineer-in-Charge. Note:- Phase should be of Red /Yellow/Blue, neutral should be of back and earthing wire should be of green colour. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length).
M&L for point wiring complete with 1.5 sq mm as per IS specification FR PVC insulated unsheathed stranded copper conductor cable drawn through and including siutable size of pvc conduit including pvc flexibal pipe and all assessories complete in walls and in steel terminals boxes suitable for switches, sockets, fan regulator etc with screw, cup washer and 1.5 sq mm copper earth continuity wire connected to celing rose to fitting and earth dolly completeall as specified and directed. Note-the rate is inclusive cutting/ chasing and making good disturbed surface with CM 1:3 and same surface finshes with the adjoining surface of disturbed area with ODB/colour wash/ white wash for the following complete all as specified and as directed by the Engineer-in-Charge.
One light/fan/bell point controlled by one switch.
One switch socket outlet type 5 pin 6 amp on same board.
All as per item No 39 above but 2.5 sq mm cable and 2.5 sq mm copper earth dolly for one switch socket outlet type 5 pin 6 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 39 above but 2.5 sq mm cable and 2.5 sq mm copper earth dolly for One switch socket outlet type 5 pin 6 amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
One sheet metal enclosure point for geyser on independent board.
Supply and fixing surface mounting tube light fitting, 1X20 watt, 230 volts 4 ft LED CRCA batten including retropit T8 glass (LED tube rod) with and including, internally pre wired with all accessories and including connecting up to fitting, complete all as specified and as directed by the Engineer-in-Charge. Make-C&S Cat Part No TARA-Mi/20.
Supply and fixing surface mounting tube light fitting, 1X10 watt, 230 volts 2 ft LED CRCA batten including retropit T8 glass (LED tube rod) with and including, internally pre wired with all accessories and including connecting up to fitting,complete all as specified and as directed by the Engineer-in-Charge. Make-C&S Cat Part No TARA-M/10.
Supply and fixing angular lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing 9 watt LED bulb complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing surface mounting round shaped LED down lighter with durable housing with aluminium heat shink with diffuser to give glare free light with removable driver 6 watt LED 6000K lamp type complete with and including, internally pre wired with all accessories, and including connecting up to fitting, complete all as specified and as directed by the Engineer-in-Charge. Make-C&S Cat Part No CORONA-RND/6W/W or equivalent in Havells/Philips/Benlo
S&F in replacement 0-4 step type electronic regulators for ceiling fan 1200 mm sweep, 240 volts, complete all as specified and as directed by the Engineer-in-Charge.
S&F call bell AC 230 volts single phase complete all as specified and as directed by the Engineer-in-Charge.
S&F bell push flush type 5 amp complete all as specified and as directed by the Engineer-in-Charge. .
S&F ceiling rose, two to three terminals complete all as specified and as directed by the Engineer-in-Charge.
S&F switch piano flush type single pole one way 5 Amp complete all as specified and as directed by the Engineer-in-Charge.
S&F socket 2 in 1, 3 pin, 5 Amps complete all as specified and as directed by the Engineer-in-Charge.
S&F switch piano flush type single pole one way 15 Amp complete all as specified and as directed by the Engineer-in-Charge.
S&F socket 2 in 1, 3 pin 5&15 Amps flush type complete all as specified and as directed by the Engineer-in-Charge.
S&F SPN DB 8 way double door type with metal door and IP 43 protetions flush mounting for MCBs & connecting complete all as specified and as directed by the Engineer-in-Charge. Make- Legrand/ABB/Crabtree.
Supply and fixing MCB DP 40 amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing MCB SP 5 to 32 Amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection complete all as specified and as directed by the Engineer-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
aggarwal engineers contractors
Gaurav Construction Company
verma enterprises
Ashish Enterprises
A R construction
KAUSHIK CONSTRUCTION CO
M/S CHANDER MUNI
tomar and associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .