Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder |
Tender Value
₹4.0 L
EMD Value
₹5,000
Closing Date
6 Dec 2022, 11:00 amClosed
HOD (CIVIL), CMPDI RI IV, JARIPATKA,NAGPUR.
CIVIL DEPARTMENT, CMPDI RI IV, JARIPATKA, KASTURBA NAGAR ,NAGPUR
Repair and renovation of pump house at RI-IV, CMPDI Complex, Jaripatka, Nagpur
2022_CMPDI_262801_1
CMPDI/RIN/CE-439(N)/2022/18
Open Tender
Civil Works - Others
Percentage
90 days
Nagpur Maharashtra
Please refer Tender documents.
10 documents required · 10 mandatory
₹5,000
3 Feb 2023
21 Nov 2022
7 Dec 2022
22 Nov 2022
6 Dec 2022
22 Nov 2022
22 Nov 2022 - 25 Nov 2022
Amount
SCHEDULED ITEMS -PART A
UNSCHEDULED ITEMS -PART B
Dismantling old C.I. pipes exposed on wall after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre: upto 300 mm dia
Providing and fixing Electromagnetic flow meter(Digital) of approved brand and manufacture . The meter shall be of full bore with rubber lining with following specifications. i)flow indicator totalizer;- 4 digit LED flow rate indicator & 9 digit LED totalizer.ii) mounting of indicator :- Integral mounting iii)Line pressure:- max 15kg/cm2 iv) I/p supply:- 230VAC.v)output -4-20mA.vi)conductivity:- minimum 5 uS/cm . vii) End connection:-flange ANSI#150 ix) body and flange,:- M.S. x) Tube :- SS 304 xi)Accuracy +/- .5%of reading xii)Electrode:- SS 316L xiii)Protection class :IP66-Aluminium Die cast Media -Water. Temperature-800 C. xiv) The meter shall have modbus O/p xv) the meter shall be with remounting .The rate shall be inclusive of testing ,calibration, cutting of existing GI pipe line, providing and fixing all necessary G I fittings like elbow socket, union etc Providing Electrical supply arrangement /battery etc complete Installation and commissioning as per instructions of Engineer In charge. . The flow meter shall carry 12 months warranty against manufacturing defects from date of commissioning.Size 50 mm dia
Providing and fixing Electromagnetic flow meter(Digital) of approved brand and manufacture . The meter shall be of full bore with rubber lining with following specifications. i)flow indicator totalizer;- 4 digit LED flow rate indicator & 9 digit LED totalizer.ii) mounting of indicator :- Integral mounting iii)Line pressure:- max 15kg/cm2 iv) I/p supply:- 230VAC.v)output -4-20mA.vi)conductivity:- minimum 5 uS/cm . vii) End connection:-flange ANSI#150 ix) body and flange,:- M.S. x) Tube :- SS 304 xi)Accuracy +/- .5%of reading xii)Electrode:- SS 316L xiii)Protection class :IP66-Aluminium Die cast Media -Water. Temperature-800 C. xiv) The meter shall have modbus O/p xv) the meter shall be with remounting .The rate shall be inclusive of testing ,calibration, cutting of existing GI pipe line, providing and fixing all necessary G I fittings like elbow socket, union etc Providing Electrical supply arrangement /battery etc complete Installation and commissioning as per instructions of Engineer In charge. . The flow meter shall carry 12 months warranty against manufacturing defects from date of commissioning.Size 100 mm dia
Providing and fixing fully automatic water level controller and LED indicator system for main pump house. The controller shall be used to start the pump and switch off the pump automatically at prescribed water level in underground sump and elevated service reservoier (30 m high). Water level indicator shall provide the available level of the water in under ground sump and the elevated service reservoier (30 m high) of four levels like minimum, mid level , 3/4th level and full level. The system shall be of approved quality & make and specifications and shall carry warranty for 12 months against the manufacturing defets etc complete as per instructions of Engineer In charge. The rate shall be inclusive of cost of electrical supply wire through switch/plug of required capacity from nearest available electrical point,sensors ,sensor cable of .4 sqmm ,4 wire etc
Providing and fixing fully automatic water level controller and LED water level indicator system for new office building pump house and overhead water tank (25m ). The contrller shall be used to start the pump and switch off the pump automatically at prescribed water level in overhead water tank). Water level indicator shall provide the available level of the water in surface ground water tank and overhead water tank (25m ) of four levels like minimum, mid level , 3/4th level and full level. The system shall be of approved quality & make and specifications and shall carry warranty for 12 months against the manufacturing defets etc complete as per instructions of Engineer In chargeThe rate shall be inclusive of cost of electrical supply wire through switch/plug of required capacity from nearest available electrical point,sensors ,sensor cable of .4 sqmm ,4 wire etc
Providing and fixing- fully automatic electronic valve of 100 mm dia for new office building surface water tank for inlet GI pipe of approved quality & make and specifications and shall carry warranty for 12 months against the manufacturing defets etc complete as per instructions of Engineer In chargeThe rate shall be inclusive of cost of electrical supply wire through switch/plug of required capacity from nearest available electrical point. sensors ,sensor cable of 0.4 sqmm ,2 wire etc. The cost shll include cutting of G I pipe providing necessary fittings like GI bend,Tee,Nipples, etc of 100 mm dia.
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .