Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.6 L+₹5.2 L (16.4%)Rejected-Finance 06 B1 LOHIYA NAGAR REHAB BLDG ST FRANCIS ROAD BHD LIC COLONY VILE PARLE WEST MUMBAI SUBURBAN MUMBAI MAHARASHTRA 400056 | MUMBAI SUBURBAN | MAHARASHTRA | 400056 | L2 | Rejected-Finance L2 | |
| 3 | L3₹38.1 L+₹6.7 L (21.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹41.2 L+₹9.8 L (31.3%)Rejected-Finance A 99 SECTOR 4 AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance L4 | |
| 5 | L5₹43.4 L+₹12.0 L (38.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹58 L
EMD Value
₹1.8 L
Closing Date
15 Feb 2024, 3:00 pmClosed
The Director, CSIR-NIO, Dona Paula, Goa
CONTROLLER OF STORES AND PURCHASE, CSIR-NIO, Dona Paula, Goa
SUPPY OF VRF OR VRV TYPE HVAC SYSTEM CAPACITY OF 64-66HP OUTDOOR UNITS AND REQUIRED QUANTITY OF HI-WALL OR CASSETTE TYPE INDOOR UNITS
2024_CSIR_182678_1
IND/236/HVAC/2023
Open Tender
Equipments (Hospital / Lab)
Supply
180 days
CSIR-NIO, REGIONAL CENTRE MUMBAI
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1.8 L
Yes
CSIR-NIO, REGIONAL CENTRE MUMBAI
22 Apr 2024
23 Jan 2024
16 Feb 2024
23 Jan 2024
15 Feb 2024
6 Feb 2024
31 Jan 2024
Amount
SUPLY OF VRF SYSTEM EQUIPMENT
SUPPLY of VRF R410a aircooled outdoor unit as per specification Supply of VRF outdoor units, with scroll compressors with all inverter, special pre-coated fins, panel, corrosion resistant (suitable for seaside installation) coated condenser, inverter based condenser fan M.S. hot dip galvanized stands / supports, electrical & microprocessor panel, isolating valves and all the necessary accessories for proper functioning of the units, having following capacities. VRF copper piping & low side works executed by low side vendor will be inspected by OEM representative as and when work progresses on the site, Minimum COP - 4.35 at 39 Deg C Outside Temp Conditions: Fire Protection Technology in Indoor as well as Outdoor in order to arrest any fire eruption. Anti-Corrosive coating is mandatory for Indoor as well as Outdoor. Operating Temp range for ODU – 52 Deg C in order to have very less Deration in case of higher Ambient Temp. Compressor must necessarily be equipped with accumulator for safety during normal operations
32 HP (16HP+16HP)
Supply of Variable Refrigerant Flow System (Imported Items-IDU with drain pump) Supply of VRF TYPE HIWALL AND 3 FEET BY 3 FEET FOURWAY CASSETTE in accordance with and meeting the intents 'of the specifications and data sheets complete with: In case of malfunction / power failure on any indoor unit the remaining indoor units and its corresponding outdoor unit should continue to perform without total system break down. Controls shall be provided to maintain the set room temperature within close tolerance limits – Operation must be Automatic without Human Interference DB Level of Hiwall - Not More than 39 DB Level of Cassette - Not More than 32
HIWALL UNITS
FOUR WAY CASSETTE UNIT
Cordless Remote
Receiver Kit (For four way cassette unit)(To be Procured from VRF Unit OEM)
Branch joints (To be Procured from VRF UNIT OEM)
S.I.T.C. OF COPPER PIPE, INSULATION, DRAIN PIPE AND ALL OTHER NECESSARY MATERIALS FOR VRF SYSTEM AND ITS INSTALLATION
SITC OF COPPER PIPING & ITS FITTING COMPLETE WITH CABLE TRAY SITC of all refrigerant piping along with nitrile rubber insulation and supports, between indoor & outdoor units duly insulated with 19mm Nirtile rubber insulation. Both Discharge and suction pipes should be of Copper material or equivalent which should be verified by the OEM of which the units are procured. (Make for copper pipes- Mandev/Mexflow/Nippon, Make for Insulation-Armaflex, K-flex, Superlon)
41.3 mm dia
34.9 mm dia
28.6 mm dia
28.6 mm dia
22.2 mm dia
19.1 mm dia
15.9 mm dia
12.7 mm dia
9.5 mm dia
6.4 mm dia
SITC PVC drain pipe with Supports & 6mm Nitrile Rubber Insulation having pressure holding of 10 kg/cm2 Drain piping complete with all accessories adaptor to join CSU & Ductable indoor units
Dia 25 mm
Dia 32 mm
Dia 40 mm
Dia 50 mm
SITC of COMMUNICATION CABLE WITH CONDUITS (1.5 sqmm, 2 core, copper flexible cable to be laid with conduit pipe along wit suitable fixtures)(Cable Make- Polycab, Finolex, Torrent, R R cables)
GAS TOPUP (R410a gas) (Make-Stallion/Honeywell)
NITROGEN TESTING
TRANSPORTATION
INDOOR HANGER SET
SITC PIPING ACCESSORIES Support rods, C-channels, Cable tray, Clamping materials, etc
Supply and installation of ANTI RUST COATING for the entire outdoor unit (PU coating done in 2 stages, Approved by the OEM)
LIFTING AND SHIFTING
INSTALLATION, TESTING AND COMMISIONING OF ENTIRE VRF SYSTEM
BUYBACK OF EXISTING VRF PLANT
REMOVAL AND DISPOSAL OF OLD SYSTEM (TO BE REDUCED FROM THE OVERALL COST) (Existing Capacity may be entered 74HP VRF outdoor units and 46 indoor units)
COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT
All in All five years comprehensive annual maintenance contract (CAMC) for the entire system including indoor and outdoor units, Electrical, electronic materials, control panels and circuits, all consumables, gas top-ups, etc., in complete respect. [This Five year AMC period will start after the completion of OEM provided Warranty period / defect liability period of 1 Year.]
FIRST YEAR (After the completion of OEM Warranty for 01st year )
SECOND YEAR
THIRD YEAR
FOURTH YEAR
FIFTH YEAR
ATS AIRCON PVT LTD
Anshutech Airconditioning Pvt Ltd
Aqua Cool Co.Pvt Ltd
Fedin Engineering Pvt. Ltd.
Vighneshwar Airconditioning pvt ltd
S D CORPORATION
ATS AIRCON PVT LTD
Anshutech Airconditioning Pvt Ltd
Aqua Cool Co.Pvt Ltd
Fedin Engineering Pvt. Ltd.
Vighneshwar Airconditioning pvt ltd
S D CORPORATION
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .