SE ETC NOIDA
220 KV SUB STATIONS SECTOR-20 NOIDA
Work of partial discharge test, internal inspection, rectification of fault, centrifuging of transformer oil etc. of 100 MVA T/F No-3 (Aditya Make) at 220 kV S/S Sector-129 under ETD-I Noida
2020_UPTCL_538699_2
E-VST-45/ETCN/2020-21
Open Tender
Electrical Works
Item Rate
15 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
EE ETD NOIDA
₹11,000
26 Dec 2020
21 Dec 2020
26 Dec 2020
21 Dec 2020
26 Dec 2020
21 Dec 2020
120 days
Amount
Carriage of 20 KL oil tanker from different substations of UPPTCL in Noida and Ghaziabad to 220 kV Sub Station Sector129 including loading and unloading at both end distance upto 100 KM. (Truck/Trailer and Crain shall be arrange by the Contactor).
Testing of partial discharge of 100 MVA Transformer No.-3 at 220 kV Sub-Station Sector-129 Noida.
After Partial Discharge test, drain out of complete Transformer oil in empty oil tanker for internal inspection of Transformer.
Opening of HV/LV side jumpers and other associated works.
Opening of inspection plate, dismantling of HV/LV side bushings for internal inspection of 100 MVA Transformer at 220 kV Sub-Station Sector-129 Noida.
Providing of dry air generator at time of dismantling of bushings, internal inspection and erection of bushings.
Internal inspection of 100 MVA Transformer, checking of HV/LV side winding lead of Transformer, tightening of joints, connections and all other components inside the main tank of Transformer for rectification of fault .
Erection of dismantled bushings and replacement of gasket of open parts of 100 MVA Transformer.
Centrifuging of Transformer oil in 20 KL oil tanker by Ultra high vacuum oil filtration plant after connecting the centrifuging the pipe with oil tanker to oil filtration plant including taking the BDV value of oil periodically till the required value is achieved. (approx. 25 KL)
Complete evacuation of 100 MVA Transformer main tank and filling of Dry air/Dry Nitrogen of dew point -50deg C or better in vacuum up to pressure of 0.25Kg/Cm2 and the again evacuating the Transformer tank after required time interval (approx 12/24 Hrs) using centrifuging machine the work shell including connecting pipe of machine as required measuring Due Point values of N2 after every cycle till the required value is achieved.
Create the vacuum inside the 100 MVA Transformer before filling the Transformer oil including vacuum standing test.
Filling of centrifuged Transformer oil from oil tanker to Transformer main tank top up in conservator tank upto required level and taking the IR/BDV value oil T/F oil at an interval of 6 hrs. as per norms of T/F manufacturer. After achieving the desired value (machine shall be provide by the Contractor) (Approx 25 KL).
Jumpering of HV/LV side bushings and ready for energize of Transformer.
Perfect Power Transformer Associates
Gupta Elect and Engg Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .