| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹5.9 L+₹2.0 L (51.0%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹5.9 L+₹2.0 L (51.7%)Accepted-Finance | L3 | Accepted-Finance L3 |
Tender Value
₹3.7 L
EMD Value
₹7,320
Closing Date
11 Mar 2020, 2:00 pmClosed
Executive Engineer Electric Division Bijbehara
Electric Division Bijbehara opp Petrol Pump
Creation of 63 kVA Sub-Station along with HT and LT Network at Hugam under Back to Village Program
2020_PDD_94114_1
EDB/e-tender/64 of 2019-20
Open Tender
Electrical Works
Turn-key
7 days
Hugam
Please refer Tender documents.
5 documents required · 5 mandatory
₹300
Executive engineer Ed Bijbehara
₹7,320
14 Mar 2020
3 Mar 2020
12 Mar 2020
3 Mar 2020
11 Mar 2020
3 Mar 2020
3 Mar 2020 - 11 Mar 2020
Amount
Creation of 63 kVA Sub-Station along with HT/LT network at Hugam
Carriage, Installation, testing & commisioing of 63 KVA (11/0.433 KV) 3-Phase dully Oil Filled Distribution Transformer (Level-2)
Supply, Erection, testing & commissioning of S.T Pole 9mtr Long SP-33 with base plate & cap for HT. Strictly as per REC standards
Supply, Erection, testing & commissioning of S.T Pole 8mtr Long SP-15 with base plate & cap for LT. Strictly as per REC standards
Supply, Laying, stringing, tensioning & binding of ACSR 30mmsq (Weasel) Conductor (for both HT/LT)
Providing & fixing of ISMC 75x40x6mm Channel iron cross arms for x-mer frame- 8 Nos @16.5 kg each 8' long including Nuts & Bolts
Supplying and erection of MS Channel “V’ cross-arm (75 x 40x6mm) with MS Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole [email protected] kg each
Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm 2.5 mtr long through GI Strip(25x3 mm) to each HT pole including supply and welding of GI channel 70x40x150 mm on pole for earth connection
Painting of poles with one coat of red oxide and two coats of Aluminium paint as per Standards. This also includes numbering of ploes with paint, submission of Pre and Post Execution photographs duly anthenticated by AEE concrened.
Supply,fixing, testing & commissioning of 11KV GO Set, AB Switch as per IS Standards
Supply,fixing, testing & commissioning of 11KV DO Fuse Set as per IS Standards
Supply,fixing, testing & commissioning of 11KV LA Set Gap less as per IS Standards
Supply,fixing, testing & commissioning of 11KV Pin Insulators with GI pins complete.
Providing & fixing of Thimbles Suitable for 63KVA DT as per standards
Providing & fixing of Soldress Clamp for 63KVA DT as per standards
Providing & fixing of LT Shackles Insulator with GI mukhi clamps including nuts & bolts
Supply, laying of 120 mmsq Single Core XLPE, FRLS unaroumed Cable
Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm, 2.5 mtr long through GI Strip of 50X6 mm for neutral earthing and 25X3 mm for 2 transformer body earth, 1 no. LA Earth and 1 no. GO handle earth. (Note: For LA Earth 1 pipe shall have to be kept separate)
Cement concreting of poles in 1:2:4 mix 0.45 cums/pole- as per REC Standards (HT Only)
Providing, Fixing of nuts and bolts for fixing of x-arms and other accessories.
Supply, installation, testing & commissioing of LT Distribution Box for 63KVA DTR with MCCB for incommer and MCCB's for outgoing ckts. With terminal extensions (Short Ckt Rating for incomer is 16kA and 100Amp MCCB)
SAJAD AHMAD RAH
M/S GHULAM QADIR RAH
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_177578.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .