Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.9 LAdmitted-Finance | -26.02% | ₹14.9 L | L1 | Admitted-Finance |
| 2 | L2₹16.7 LAdmitted-Finance | -17.13% | ₹16.7 L | L2 | Admitted-Finance |
| 3 | L3₹17.1 LAdmitted-Finance | -15.00% | ₹17.1 L | L3 | Admitted-Finance |
| 4 | L4₹18.1 LAdmitted-Finance R O VILLAGE KOTLA TEHSIL KATRA DISTRICT REASI | -10.00% | ₹18.1 L | L4 | Admitted-Finance |
| 5 | L5₹19.8 LAdmitted-Finance | -1.35% | ₹19.8 L | L5 | Admitted-Finance |
Updated dates
Tender Value
₹20.1 L
EMD Value
₹41,000
Closing Date
16 Jan 2026, 3:00 pmClosed
Dy. CEO (P)
SMVDSB, Katra
Repair and renovation of SKC quarters on Chiterkoot on Hathimatha Track at RD 6/500
2025_SMVSB_299176_1
e-NIT No. CO/DEV/691/5946 DT 26.12.2025
Open Tender
Civil Works
180 days
SMVDSB, Katra
refer bid document
4 documents required · 4 mandatory
₹1,000
FA/CAO, SMVDSB
₹41,000
28 Jan 2026
26 Dec 2025
17 Jan 2026
26 Dec 2025
16 Jan 2026
26 Dec 2025
Civil Works
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead: 15.12.2 Of area beyond 3 sqm
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 (1 cement: 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in: Cement mortar 1:4 (1 cement: 4 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
15mm Cement plaster on the rough side of single or half brick wall of mix:1:6(1 cement: 6 fine sand)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to 1.5. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 15:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (Icement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 600x600 mm
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15", landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for:
Suspended floors, roofs, landings, balconies and access platforms
Lintel, beams, plinth beams, girders, bressumers and cantilevers
Columns, pillars, piers, abutments, posts and struts
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: - Butt hinges and necessary screws shall be paid separately). Second kail wood 35mm thick
Providing and fixing panelling or panelling and galzing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Particle Board 12mm thick Plain particule board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked
Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge: Second class Kail wood
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood 35mm thick
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade FE-500D or more
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: Ordinary Rock.
Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63mm thick with zinc coating not less than 275 gram/m2
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/llitre, two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2mm thick
Carriage of material by Mechanical Transport including loading unloading and stacking complete. Sand average lead 55 Km
Crushed Aggregate below 40m nominal size average lead 25 Km
Brick average lead 60 Km
Carriage of material by Mechanical Transport from Katra to Adhkuwari. Sand, Cement, Bricks, Aggregate, Steel
Electrical Works - WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. - Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4.00 sq. mm + 1 X 4.00 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required - 25 mm Conduit.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (Make: - Legrand (Mylinc) / Havell's (Coral)
Modular Switch 5/6 Amp.
Modular Switch 15/16 Amp.
Modular Socket 3 pin 5/6 Amp.
Modular Socket 6 pin 15/16 Amp.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make: - Legrand (Mylinc) / Havell's (Coral)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Make: - Legrand (Mylinc) / Havell's (Coral)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Make: - Legrand (Mylinc) / Havell's (Coral)
3 Module (100 mmX75 mm)
4 Module (125 mmX75 mm)
6 Module (200 mmX75 mm)
MCCB, MCB & DB’s
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. (Make: - ABB/ Schinder/ Legrand/ L&T) 100 Amps TP&N
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: - ABB/ Schinder/ Legrand/ L&T) 12- way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: - Havell's/ ABB/ Schinder/ Legrand/ L&T) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: - ABB/ Schinder/ Legrand/ L&T)
Single pole
Single pole and neutral 40/63 Amp.
Installation, Testing and Commissioning Supply,Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
LED Tube fitting 14-20 Watt 4 feet long. (Batten 4')
LED Tube fitting 10 Watt 2 feet long. (Batten 2')
Fixing of Old ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
BOQ_970483.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid