Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | ₹1.8 Cr Quoted ₹1.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.9 Cr+₹60,368.30 (0.32%)Rejected-Finance AT BARIMAL PO HATIBARI PS SUKINDA DIST JAJPUR PIN 755018 | JAJAPUR | ODISHA | 755018 | ₹1.9 Cr+₹60,368.30 (0.32%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.9 Cr+₹5.7 L (3.05%)Rejected-Finance | ₹1.9 Cr+₹5.7 L (3.05%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹2.3 Cr+₹44.6 L (23.8%)Rejected-Finance | ₹2.3 Cr+₹44.6 L (23.8%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹2.4 Cr+₹48.2 L (25.8%)Rejected-Finance | ₹2.4 Cr+₹48.2 L (25.8%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
7 Feb 2022, 6:00 pmClosed
CWE No 2 Visakhapatnam
Commander Works Engineer 2 ,Chief Engineer Navy Visakhapatnam Complex, Station Road, Visakhapatnam, 530004
SPECIAL REPAIRS TO ASHOK DIVISION BLDG NO T 42 A AT INS CHILKA
2022_MES_498788_1
82541
Open Tender
Civil Works
Item Rate
270 days
GE CHILKA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE CHILKA
₹2.6 L
Yes
18 Apr 2022
1 Jan 2022
11 Feb 2022
1 Jan 2022
7 Feb 2022
25 Jan 2022
1 Jan 2022 - 31 Jan 2022
Amount
Taking down existing waterproofing treatment complete of any description from brick or RCC wall and RCC slab by scrapping including removal of rubbish where directed to a distance not exceeding 100m all as specified and directed by Engineer in charge
M&L for rendering 10mm thick on fair faces of brick or concrete sufaces in cement mortar 1:3 with WPC @ 3% by weight of cement content complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately.
M&L for water proofing roof treatment, consists of a five layered Atactic polypropylene modified polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm, with and including priming the surface with a coat of hot blown bitumen of grade 85/25 @ 1.2 kg/Sqm each at top and bottom of the membrane as bonding material, and a coat of bituminous aluminium primer @ 100 gm/Sqm on top, including sealing all joints by thermo fusion, complete all as per manufacturer's instructions.
S&F 1000 ltr capacity Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including provision of inlet, outlet overflow and wash out connections and taking down the existing unserviceable tank complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforced cut as required to facitade demolition) complete all as specified and directed.
M&L Mild steel TMT bar 10mm Dia and over cut to length bent to shape reqd incl cranking bending spirally for hooping for column hooking end and binding with and incl mild stel wire(annealed) not less than 0.9mm Dia or securing with clip.
M&L RCC nominal mix (1:2:4) type B-1 using 20mm graded aggregate as in chajjas complete all as specified and directed.
M&L for use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finish surfaces
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.00 kg of cement per Sqm complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 Sqm but not exc 0.36 sqm, in floors etc set and joint in neat cement slurry and pointed in white or colour cement to match including 15mm thick rendering in CM 1:4 complete all as specified and as directed
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 Sqm but not exc 0.18 sqm, in floors etc set and joint in neat cement slurry and pointed in white or colour cement to match including 15mm thick rendering in CM 1:4 complete all as specified and as directed
S&F Coloured Glazed ceramic tiles in vertical surfaces 350x250x7mm /450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match in vertical surfaces such as skirting / dado etc including 10 thick rendering/backing coat vertical surfaces in CM 1:4 all as specified.
M&L for chequered cement concrete tiles 20cmx20cmx 25mm thick for stair case , set jointed and pointed in neat cement slurry in floor with grey cement and pigment including 20mm thick screed bed in CM 1:4 all as specified and as directed.
S&F in repairs CP Bib taps in 15 mm dia chromium plated cast copper alloy, fancy type screwed down for iron pipe complete all as specified and directed.
S&F in repair CP tubular towel rail, 20mm dia D type 600mm long as in repair, brass chromium plated and fixed all as specified and directed by Engr-in-Charge
S&F in repair PVC soap tray fixing with screw in the all as specified. (Make : Prayag /Parry ware and equivalent)
S&F in repair water closet Vitreous China, semi-pedestal pattern (Anglo-Indian Type) including and connection to drain and to flush pipe & mild steel chromium plated or aluminised hinging device etc (excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in-Charge.
S&F PVC floor trap with grating including jointing with solvent cement to waste pipe 75 mm dia complete all as specified and directed
S&F Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) all as directed and specified
S&F in repair PVC (EWC) water closet seat, white colour, closed pattern with flat bottom, and cover and mild steel chromium plated or CP hinging device complete all as specified and directed.
S&F in repairs shower rose brass chromium plated of size 125 mm with swivel joint fixing to GI pipe of 15 mm dia including GI Elbow and nipple as in repairs as specified and directed by Engr-in-Charge.
S&F in repair 15mm dia chromium plated, fancy type stop valves, cast copper alloy, screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified
S&F in repair 25mm dia CP flush cock half turn with adjustable flange complete all as specified and directed, Make : Prayag/Parry ware or equivalent.
Taking down eaves gutters and rainwater pipes (any size of pattern) including all fittings, heads, shoes, bends, swan-necks etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre lineover fittings and accessories) complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls & floors 110 mm bore complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls & floors 75 mm bore.
S&F in repair 110 bore PVC (SWR) bends any radius complete all as specified and directed
S&F in repair 75 bore PVC (SWR) bends any radius complete all as specified and directed
S&F in repair PVC (SWR) double ‘Y’ junction of 110mm dia all as specified and as directed.
S&F in repair PVC (SWR) double ‘Y’ junction of 75mm dia all as specified and as directed.
S&F in repair PVC (SWR) reducer 110/75mm dia all as specified and as directed.
S&F in repair 110 bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified and directed
S&F in repair 75 bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified and directed
S&F 110 bore PVC (SWR) vent cowl complete all as specified and directed
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal from site of size 15mm bore of dia complete all as specified & directed.
Ditto all as per item no.37 above but 20mm dia
Ditto all as per item no.37 above but 25mm dia
Ditto all as per item no.37 above but 32mm dia
Ditto all as per item no.37 above but 40mm dia
Ditto all as per item no.37 above but 50mm dia
Refixing old GI steel tubing and connections in new or old position (Walls, ceiling, floors etc) of size 15mm bore of dia complete all as specified & directed.
Ditto all as per item no.43 above but 20mm dia
Ditto all as per item no.43 above but 25mm dia
Ditto all as per item no.43 above but 32mm dia
Ditto all as per item no.43 above but 40mm dia
Ditto all as per item no.43 above but 50mm dia
S&F GI tubes, 'medium grade' galvanised, with all fittings and fixed to walls and in ceilings of size 15mm bore complete all as specified and directed.
Ditto all as per item no.49 above but 20mm dia
Ditto all as per item no.49 above but 25mm dia
Ditto all as per item no.49 above but 32mm dia
Ditto all as per item no.49 above but 40mm dia
Ditto all as per item no.49 above but 50mm dia
S&F gun-metal, globe or gate valves 50mm bore, with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed.
Ditto all as per item no.55 above but 40mm dia
Ditto all as per item no.55 above but 32mm dia
Ditto all as per item no.55 above but 25mm dia
Ditto all as per item no.55 above but 20mm dia
Taking down cement plaster on brick or stone walls etc including racking out joints, backing for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 5mm thick on ceiling surfaces in CM 1:3 including finishing even & smooth without using extra cement for patch work, complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick or concrete sufaces in cement mortar 1:6, including finishing even and smooth without using extra cement, complete all as specified and as directed.
M&L for rendering 15mm thick in two layers on fair faces of brick or concrete sufaces in cement mortar 1:4, including finishing even and fair (without using extra cement) mixed with WPC @ 3% by weight of cement content complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound
M&L preparation of new plastered surfaces and applying three coats of white wash on ceiling surface complete all as specified
M&L preparation of new plastered surfaces of walls and applying three coats of white wash on wall surface complete all as specified
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coat oil bound distemper over a coat of primer complete all as specified and directed
M&L for preparation of new plastered external wall surfaces of any description over 10 cm width/girth and including applying two coat of weather coat anti dust emulsion paint, exterior grade of approved shade over a coat of alkali guard anti efflorescence primer as per manufacturer's instruction complete all as specified and as directed by Engineer -in - Charge.
Taking down chowkats or frames not exceeding 1.5 Sqm each but with shutters (without taking off shutters from the frames) all as specified.
Taking down chowkats or frames exceeding 1.5 Sqm and not exceeding 4 Sqm each but with shutters (without taking off shutters from the frames) all as specified.
Refixing of chowkhats or frames exc 1.5 Sqm but n exc 4.0 Sqm each in same opening complete all as directed
Taking down Shutters of any description not exceeding 1 sqm each and refixing in the same opening complete all as directed
M&L for Preparing surfaces of wood and wood based materials and treated with tar or coal tar black paint for back of chowkhats etc area exceeding 0.10 Sqm but not exceeding 0.5 Sqm each all as specified.
Cutting holes in brick walls/stone wall exceeding half brick but not exceeding one brick in cement mortar for inserting holdfasts and making good dismantled protiion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required.
S&F MS flat iron conforming to Fe290-0 Gde E-165 as in hold fasts etc bend to shape as required all as specified.
S&F 2nd class hard wood plain, solid straight chowkats and frames, wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and as directed
S&F 2nd class hardwood plain, 30mm thickness of shutter Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc divided into squares, with plain, chamfered or roun ded, mitred and rebated sash bars, any numbers edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass ,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified and as directed.
S&F 30 mm thick, 2nd class hard wood, plain, framed panelled shutters (any number of panels), with panels of timber flat on both side (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied & fitted to chowkats all as specified.
S&F MS 150mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and fixed in aluminium windows all as specified and directed by Engineer-in-Charge complete all as specified.
S&F Powder coated anodised aluminium frame for windows/ventilator with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.
S&F Anodised Powder coated aluminium window shutters, sliding type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings including locking arrangements with lock (minimum thickness of powder coating 50 micron) all as specified and as directed.
S&F Anodised Powder coated aluminium window & ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stas 150mm long (1 No) hinge type B-21 100mm long (2 No) suitable handle (1 No) complete all as specified.
S&F sheet glass 4.0 mm thick ordinary quality and glazing with oil putty/ beading in squares not exceeding 0.5 sqm each pane for fixing to aluminium or wooden joinery work complete all as specified and as directed.
Material and labour for machine cut kota stone slab flooring 18-20mm thick over 15mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
M&L for Machine cut kota stone slab 18-20mm thick riser of steps / skirting /dado and pillars laid over cement screed 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed
S&F Aluminium anodised powder coated of any colour (thickness of powder coating not less than 15 micron) Deco grill DG 202 with aperature size 60X45mm fixed with suitable channel for windows/ventelator fixing arrangements all as specified and as directed.
S&F aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F aluminium, anodised barrel tower bolts of extruded section of size 150 mm long
S&F aluminium, anodised barrel tower bolts of extruded section of size 100 mm long
S&F Aluminium handles 125mm size, cast type, anodised complete all as specified and as directed.
S&F 100 mm butt hinges, medium weight, cold rolled mild steel, and fixed all as specified and as directed.
M&L Preparing new wooden surfaces of any description exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC Sheet & edges will be painted to match with prelam sheet, reinforced with MS Square tube supplying & fixing in opening as per specification complete as directed
S&F Factory made solid panel PVC door shutter 30 mm thick (style) considering of frame made out of MS tubes for top & bottom rails M.S frame shall be covered with heat moulded both side Prelam PVC sheet used PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification complete as directed.
S&F in repair plain mild steel wire galvanised class 3 (dia of wire 4mm) in fencing/cloth line with pvc coated including straining and fixing to steel post and to straining bolts, including securing with and provision of galvanised iron tying wire or staples or steel pins etc including removing of old wire complete all as specified and directed.
Demolition of masonary work like precast concrete loures/jallies built in cement mortar complete all as specified and directed.
Demolition of brick work/stone masonry built in cement mortar and removal of rubbish from site complete all as specified and directed.
M&L brick work with fly ash bricks, straight or curved on plain exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
M&L for rendering 10mm thick on fair faces of brick or concrete sufaces in cement mortar 1:3 using WPC @ 3% by weight of cement content on sunken floor concrete complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately.
M&L for PCC 1:5:10 type E2 (using 40mm graded stone aggregate) as in sunken floor treatment complete all as specified and as directed
M&L 40 mm thick PCC 1:2:4 type B1 (20 mm grade aggregate) as in sub base (Sunken floor) finishing cement concrete surface even and smooth without using extra cement
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Dismantling type 3 ballies, hard or soft wood, any position, except in posts and struts; including taking out iron straps, bolts and nuts, etc., if any complete all as specified and as directed
M&L for Framed work such as grills, gratings, hold fasts etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, ladders framed balusters, and similar work conforming to Fe-290-0 or Fe-310-0, incl portions framed and hung as gates, pintle hinges,stops,hand-made sliding bolts etc.complete all as specified.
M&L preparation of sreel surfaces of any description over 10cm in width or girth, and painting two coats of synthetic enamel paint over a coat of red oxide zinc primer complete all as specified and as directed
M&L for IInd class hard wood handrails of size 100X75mm moulded or shaped with splayed faces in straight lengths and fixed to the iron balusters complete all as specified and as directed.
S&F for 25mm thick pre-formed filler (bituminous pad) for crumple/expansion joints with Joint Sealing Compound Grade “A” (Normal) in 25/30 Kg complete all as specified and as directed.
S&F in repairs 0.56mm thick plain aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the places can be cut) complete all as specified and directed.
M&L for PCC 1:2:4 Type B0 (12.5mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-in-Charge
M&L for preparation old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces by brooming down or steel wire brushing, scraping down moulds, mass and efflorenscent salts and greasy spots of wall and applying one coat of oil bound distemper of approved shade complete all as specified and directed by Engr-in-Charge.
M&L for old decorated surfaces of walls by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of white washing on walls all as specified
M&L for preparation old decorated surfaces of ceiling by washing, rubbing down and stopping of distempered surfaces by brooming down or steel wire brushing, scraping down moulds, mass and efflorenscent salts and greasy spots of ceiling and applying one coat of oil bound distemper of approved shade on ceiling complete all as specified and directed by Engr-in-Charge.
M&L for preparing old decorated plastered surfaces including brooming down or steel wire brushing, scraping down moulds, mass and efflorescent salts and greasy spots and applying two coat of white wash on ceiling all as specified.
M&L for preparation of old plastered decorated surfaces of external wall by brooming down or steel wire bruching, scraping down smoke soot, moulds, moss and efflorescencent salts and trading oil and greasy spots of any description over 10 cm width/girth and applying one coat of weather proof anti dust emulsion paint, exterior grade of approved shade as per manufacturer's instruction and also rewrite the bldg No as per existing font style and size with enamel paint of approved shade complete all as specified and as directed.
M&L Preparing old treated wooden surfaces of any description exc. 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed
M&L preparing old treated steel surfaces of any description over 10cm in width or girth, and painting one coat of synthetic enameled paint of approved shade complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thick (below or above ground level) complete all as specified and as directed.
M&L for 75mm thick cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base for hard standing/pathway complete all as specified and directed
M&L 75mm thick PCC 1:2:4 type B2 using 40mm graded stone aggregate as in hard standing / path way etc and finishing surface by brooming when the concrete is green.complete all as specified and directed.
M & L for forming Construction joint 30mm deep x 10mm wide filled with sealing Grade 'A' (joints shall be formed with mechanical cutter) compound complete all as specified and directed.
M & L for dummy joints 60mm deep x 10mm wide filled with sealing Grade 'A' (joints shall be formed with mechanical cutter) compound complete all as specified and directed.
M & L for walling of random rubble masoney, uncoursed , well bonded bedded and solidly hearted , built in cm 1:6 complete all as specified
All as per item no.125 above but except stone Note : Serviceable RR stones from demolition shall be reused.
M & L for flush pointing to random rubble masonry uncoursed or brought upto courses in CM (1:4) complete all as specified and directed.
M & L for flush pointing to random rubble masonry uncoursed or brought upto courses in CM (1:4) including racking out of joints in repair work complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping , cills etc complete all as specified and directed.
M&L PCC 1:2:4 type B2 using 40mm graded stone aggregate in surface channels and drains complete all as specified and directed.
Taking down carefully copper / aluminium point wiring surface/concealed [light, fan, socket, ceiling or power] complete including fittings, switches, ceiling roses, pendents, regulators, sockets, holders stair case light etc., and making good the disturbed surfaces complete all as specified.
M&L Point wiring concealed with 2 runs of 1.5 Sqmm (Nominal area) PVC insulated, unsheathed cable FRLS grade with copper conductors, single core, multi stranded 1100 Volts, ISI marked (IS 694) (For Phase, neutral ) drawn through and including 20mm dia PVC rigid conduit ISI marked, (IS 9537 Part III) Heavy grade with conduit accessories including concealed steel terminal boxes fabricated out of 2mm thick MS sheet, fitted with PVC modular plate for fixing switches, sockets etc, including 1.5 sq mm FRLS multistranded copper conductor cable as continuous earth wire complete and connecting the earth wire to common earth dolly for one light/fan/ bell/5 amp socket point controlled by one switch complete all as specified.
All as per item no. 132 above but light point controlled by 2 nos of 2 way switches as in staircase lighting
All as per item no.132 above but 2 runs of 2.5Sqmm PVC insulated unsheathed multistranded copper FRLS grade cable including one run of 2.5sqmm PVC insulated unsheathed copper cable as earth continuity for power socket on independent board
Taking down carefully sub main wiring including batten/conduit by unscrewing from wall,ceiling,etc., and making good the disturbed surfaces complete all as directed.
M&L for sub main wiring concealed with two runs of 4 sq. mm multistranded copper conductor cable FRLSH grade 1100 volt and one run of 4 Sq.mm multistranded copper conductor cable FRLSH grade 1100 volt drawn through and including PVC rigid conduit heavy grade 25 mm dia complete all as specified. Note: Three runs of 4 Sq.mm cable and one run of PVC conduit will be measured as one unit.
M&L for sub main wiring concealed with two runs of 6 sq. mm multistranded copper conductor cable FRLSH grade 1100 volt and one run of 6 Sq.mm multistranded copper conductor cable FRLSH grade 1100 volt drawn through and including PVC rigid conduit heavy grade 25 mm dia complete all as specified. Note: Three runs of 6 Sq.mm cable and one run of PVC conduit will be measured as one unit.
M&L for sub main wiring concealed with four runs of 6 sq. mm multistranded copper conductor cable FRLSH grade 1100 volt and one run of 6 Sq.mm multistranded copper conductor cable FRLSH grade 1100 volt drawn through and including PVC rigid conduit heavy grade 25 mm dia complete all as specified. Note: Five runs of 6 Sq.mm cable and one run of PVC conduit will be measured as one unit.
S & F Modular switch flush type single module one way, 5/6 Amps, 230 Volts,50Hz complete all as specified.
S & F Modular switch flush type single module two way, 5/6 Amps, 230 Volts,50Hz complete all as specified.
S & F for Modular socket out let 3 pin 5 Amps flush type, 230V, double module complete all as specified.
Supply and fixing of modular switch flush type, single module, one way, 15/16 Amp, complete all as specified.
S&F Modular type socket 2/3 pin, 6/16 Amps flush type, 230V double module complete all as specified and directed.
S&F ceiling rose surface backlite 3 terminals 65X50mm 230V including PVC Box of size 3"X3" round type complete all as specified
S&F modular stepped type fan regulator 2 module as per site requirement to use in wiring socket type 300 Watt complete all as specified
Taking down defective exhaust fan and wall mount fan from its position and refixing the same after minor repairs complete all as directed by Engr-in-Charge. Note := Spare parts replaced for defective parts shall be measured and paid as `supply only` against respective items
M&L Painting of ceiling fans with blades complete in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler,including complete cleaning all dust, dirt etc and preparing the surface complete all as directed by Eng-in-charge.
All as per item No.147 above but for Exhaust fan of 450 mm sweep of any make and painted with grey colour.
Taking down carefully defective ceiling fans from its position and refixing back to its original position after repairs complete all as directed Note := Spare parts replaced for defective parts shall be measured and paid as `supply only` against respective items
Rewinding of ceiling fan motor of type 1200 mm sweep and any make with super enamelled copper wire of appropriate guage including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish,greasing the bearings,replacement of missing/worn out nuts,bolts,washers,split pins,etc complete all as directed by Eng-in-charge.
All as per item No. 19 above but for Exhaust fan motor of 450 mm sweep of any make complete all as specified and as directed.
Supply and fix in replacement of new ball bearing 6201 / 6202 / 6203 including metal filling, machining if required, complete all as specified. Make : SKF/NBC
Supply only canopy (upper and lower) to match the ceiling fan of make/model as per site complete all as specified.
Supply only gun metal bush, suitable for any make and sweep ceiling fan complete all as specified.
Supply only fan clamp with nut & bolt and rubber bush suitable for ceiling fan of any sweep and make, complete all as specified.
Supply only ceiling fan capacitor/condensers 2.5 mfd of approved make complete all as specified. MAKE : NICCO/Havells/Universal.
Supply only exhaust fan capacitor 4 mfd of approved make complete all as specified. MAKE : NICCO/Universal/Havells.
S&F 20 W tubelight fitting with lamp, Endura linear LED Wall mounted LED batten with polycarbonate housing & integrated driver for efficient heat dissipatio with complete fitting. make: Havell Cat part No.- LUMILINEBS20WLED865SPCWH, Bajaj Cat part No. BCLSB 20 WH or equvalent to philips//CG/Surya roshini
S&F 9 W LED tubelight fitting with lamp, Endura linear LED Wall mounted LED batten,exruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver with complete fitting.
Supply and fixing LED street light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-charge. Make : Havells cat part No.VILUMINASL25W LED757SASYBOPC or PHILLIPS cat part No.BRPO42PLED25CWSLE S1 PSU GR P4210 or equivalent Crompton Greaves.
Taking down carefully old un serviceable MCB DBs with MCBs of any type by unscrewing from wall,ceiling,etc., and making good the disturbed surfaces to match the original status complete all as directed.
S & F MCB DB,SPN, sheet metal enclosure, double door type, 8 way,AC,240 V with 200 Amps rated bus bar,complete all as specified and directed by Eng-in-charge.
S & F MCB DB,TPN, sheet metal enclosure, double door type, 4 way,AC,415 V with 200 Amps rated bus bar complete all as specified and directed by Eng-in-charge.
S & F Vertical distribution board,double door type, 8 way,with provision to mount MCCB TP upto 250 Amps 36KA as incomer and MCB SP as outgoing,415 V with 200 Amps rated bus bar complete all as specified and directed by Eng-in-charge.
Taking down carefully old unserviceable MCB/MCCB any type by unscrewing from wall,ceiling and making good surfaces to match with original status as specified and directed.
S & F MCB SP 6 to 32 Amps, C Series,240 Volts , complete all as specified and directed by Eng-in-charge.
S & F in repair MCB SPN 40 Amps,240 Volts , C series complete all as directed by Eng-in-charge.
Supply & fix Isolator three pole 100 Amps 415 volt 50 Hz complete all as directed by Eng-in-charge.
Supply & fix MCB four pole 63 Amps 415 volt 50 Hz complete all as directed by Eng-in-charge.
Supply & fix in replacement MCCB 200 Amps 36 KA 4 pole 415 Volts 50 HZ. Make Indoasian/GE/Havells/HPL/Legrand/C&S
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 M below ground level connected with galvanised earth wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron to earth test point all as specified or indicated including necessary excavation and earth work any type of soil PCC (1:3:6) watering funnel, GI tubing 20 mm for watering all as specified and directed and all as shown in electrical plate No.5 of SSR part 1.
M&L for water proofing roof treatment for sunken floors, consists of a five layered Atactic polypropylene modified polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm, with and including priming the surface with a coat of hot blown bitumen of grade 85/25 @ 1.2 kg/Sqm each at top and bottom of the membrane as bonding material, and a coat of bituminous aluminium primer @ 100 gm/Sqm on top, including sealing all joints by thermo fusion, complete all as per manufacturer's instructions.
ANIL KUMAR BISWAL
PEARL CORPORATION
Sri Surya Enterprises
srisampathassociates
SOUTHERN BUILDERS
M/s KRK Raju Constructions
SRI SURYA PROJECTS
S A R CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .