Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance DB 6 A HARI NAGAR NEW DELHI 64 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
16 Mar 2021, 12:00 pmClosed
Atul Bhardwaj
Ex. Engineer (E)/WZ
Provision for EI, Fans and compound lighting of newly constructed CSE office with a toilet block near the gate of MC Primary School on Old Pankha Road in Ward no 18-S/WZ in Milap Nagar.
2021_SDMC_72747_1
EE/Elect/WestZone/2020-21/22
Open Tender
Electrical Works
Works
30 days
Rajouri Garden
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
Commissioner SDMC
Exempted
17 Mar 2021
9 Mar 2021
17 Mar 2021
9 Mar 2021
16 Mar 2021
9 Mar 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 × 2.5 sq. mm + 1 × 2.5 sq. mm earth wire
2 × 4 sq. mm + 1 × 4 sq. mm earth wire
4 × 2.5 sq. mm + 2 × 2.5 sq. mm earth wire
4 × 4 sq. mm + 2 × 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes. (a) 2 x 6 sq mm
S.I.T.C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium batten prewired with high efficient LEDs with the following . (a) Total system wattage 20 watt +/-5% (c) Luminous efficacy lumens/Watt>=95 (d) Power Factor>=0.95
providing and fixing circular/Hexagonal cast iron M.S. Sheet box for ceiling fan Clamp of internal dia 140mm,73mm height,top lid of 1.5 mm thick MS sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/MS sheet box by means of 3.3mm dia round headed screws,one lock at the corners,clamp shall be made of 12 mm dia MS bar bent to shape as per standard drawing.
SITC Of single phase monoblock pump set complete with all accessories workable on 240/415 volts, 50 Hz ac supply. (a) 1 HP (0.75 KW) single phase pump set, head from 12-30 metre suction and delivery 25x25 mm
Supply of 1200 mm Sweep 50 Watt, Energy saver ISI Marked BEE 5 Star rating AC Ceiling fan suitable for 230 V, 50 Hertz AC Supply without regulator with blades, down rod etc. complete as required.
Supply of 12" (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as reqd.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 25A
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .