COL PALLAWA JHA CWE
HQ CWE MAMUN PIN - 145001
SPL REPAIR AND IMPROVEMENT OF OVERHEAD HT LT NETWORK AND CONNECTED ITEMS UNDER GE S MAMUN AT MAMUN MIL STN
2026_MES_799601_1
CWE/M-TOKEN47/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
MAMUN
As per tender documents
9 documents required · 9 mandatory
₹1,000
Yes
GE SOUTH MAMUN
₹1.5 L
Yes
20 Nov 2026
20 Nov 2026
26 Dec 2026
20 Nov 2026
19 Dec 2026
12 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 40mm dia light grade GI pipe for earth strip protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete. | 50 | Each | - | - |
| 2 | Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3m, including getting out in any type of soil (the excavated soil) and disposal of surplus excavated soil, within a lead of 50m complete all as specified and directed. | 4,391 | Cum | - | - |
| 3 | Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and as directed. | 3,859 | Cum | - | - |
| 4 | M&L for double walled corrugated (DWC) pipe for cable protection with outer dia 40mm and inner dia 30mm including suitable size of coupler for connection of pipe complete all as specified and directed. | 9,712 | RM | - | - |
| 5 | M&L for double walled corrugated (DWC) pipe for cable protection with outer dia 50 mm and inner dia 38 mm including suitable size of coupler for connection of pipe complete all as specified and directed. | 2,400 | RM | - | - |
| 6 | M&L for double walled corrugated (DWC) pipe for cable protection with outer dia 63mm and inner dia 50mm including suitable size of coupler for connection of pipe complete all as specified and directed. | 1,944 | RM | - | - |
| 7 | M&L for double walled corrugated (DWC) pipe for cable protection with outer dia 75mm and inner dia 61mm including suitable size of coupler for connection of pipe complete all as specified and directed. | 200 | RM | - | - |
| 8 | M&L for double walled corrugated (DWC) pipe for cable protection with outer dia 90mm and inner dia 76mm including suitable size of coupler for connection of pipe complete all as specified and directed. | 24 | RM | - | - |
| 9 | M&L for un-reinforced precast concrete cable cover, class HV, type 1, flat, size 300mm x 180mm x 40mm complete all as specified and directed. | 2,382 | Each | - | - |
| 10 | M&L for sand cushioning to under ground cables, 8 cm thick before laying the cable and 15cm thick after laying, stretching and testing the cable complete all as specified and directed.
Note:- Only punned thickness i.e 18cm will be measured and paid. | 35 | Cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
BOQ_897136.xls
BOQ • 0.68 MB
TENDER47.pdf
Tender Documents • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .