Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.8 LAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹29.4 L+₹3.4 L (13.1%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹30.0 L+₹4.0 L (15.3%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-3 | Rejected-Finance L-3 | |
| 4 | L-3₹30.0 L+₹4.0 L (15.3%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 5 | L-4₹33.5 L+₹7.5 L (28.8%)Rejected-Finance | L-4 | Rejected-Finance L-4 |
| Sl No | Description | Qty | Unit | NAVYUG VYAPARI L2 | sheetal engineering L4 | Surjit and Sons L8 | M/S Anand Enterprises L3 | Singh Associates L6 | Vijeta Solutions L7 | M/S ADHIKARI CONSTRUCTION CO. L1 | M/S Parshant Associates L3 | PARAS ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed. | 955 | Per Point | 5 ₹4,775 Lowest | 9 ₹8,595 | 5 ₹4,775 Lowest | 10 ₹9,550 | 20 ₹19,100 | 9 ₹8,595 | 9 ₹8,595 | 10 ₹9,550 | 10 ₹9,550 |
| 2.00 | M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators complete all as specified and directed.
NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls. | 300 | Per Point | 220 ₹66,000 | 300 ₹90,000 | 325 ₹97,500 | 180 ₹54,000 | 450 ₹1,35,000 | 129 ₹38,700 Lowest | 199 ₹59,700 | 180 ₹54,000 | 320 ₹96,000 |
| 3.00 | All as per item No 2 above but 5 Amp socket outlet, independent. | 80 | Per Point | 220 ₹17,600 | 300 ₹24,000 | 325 ₹26,000 | 250 ₹20,000 | 480 ₹38,400 | 159 ₹12,720 Lowest | 199 ₹15,920 | 250 ₹20,000 | 320 ₹25,600 |
| 4.00 | All as per item No 2 above but on the same board. | 50 | Per Point | 100 ₹5,000 | 300 ₹15,000 | 100 ₹5,000 | 150 ₹7,500 | 300 ₹15,000 | 89 ₹4,450 Lowest | 199 ₹9,950 | 150 ₹7,500 | 150 ₹7,500 |
| 5.00 | All as per item No 2 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable. | 25 | Per Point | 120 ₹3,000 | 300 ₹7,500 | 325 ₹8,125 | 300 ₹7,500 | 500 ₹12,500 | 89 ₹2,225 Lowest | 199 ₹4,975 | 300 ₹7,500 | 300 ₹7,500 |
| 6.00 | All as per item No 2 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly. | 100 | Per Point | 250 ₹25,000 | 390 ₹39,000 | 440 ₹44,000 | 250 ₹25,000 | 600 ₹60,000 | 189 ₹18,900 Lowest | 299 ₹29,900 | 250 ₹25,000 | 450 ₹45,000 |
| 7.00 | M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through PVC casing caping of ISI marked with fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators complete all as specified and directed.
NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls. | 200 | Per Point | 180 ₹36,000 | 300 ₹60,000 | 375 ₹75,000 | 180 ₹36,000 | 450 ₹90,000 | 129 ₹25,800 Lowest | 199 ₹39,800 | 180 ₹36,000 | 300 ₹60,000 |
| 8.00 | All as per item No 7 above but 5 Amp socket outlet, independent. | 75 | Per Point | 180 ₹13,500 | 300 ₹22,500 | 375 ₹28,125 | 300 ₹22,500 | 480 ₹36,000 | 179 ₹13,425 Lowest | 199 ₹14,925 | 300 ₹22,500 | 300 ₹22,500 |
| 9.00 | All as per item No 7 above but on the same board. | 25 | Per Point | 100 ₹2,500 | 300 ₹7,500 | 100 ₹2,500 | 150 ₹3,750 | 300 ₹7,500 | 79 ₹1,975 Lowest | 199 ₹4,975 | 150 ₹3,750 | 150 ₹3,750 |
| 10.00 | All as per item No 7 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly complete all as specified and directed. | 100 | Per Point | 250 ₹25,000 | 390 ₹39,000 | 475 ₹47,500 | 350 ₹35,000 | 600 ₹60,000 | 201 ₹20,100 Lowest | 299 ₹29,900 | 350 ₹35,000 | 450 ₹45,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
31 Jul 2025, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/REPLACEMENT OF INTERNAL WIRING, SUMMER APPLIANCES, HOT WATER APPLIANCES, EARTHING PITS, LIGHTENING ARRESTORS, UG PIPELINES, CENTRIFUGAL PUMP SETS AND OTHER E/M INSTALLATION AT AF STN NARAINA UNDER AOR OF GE (AF) FARIDABAD
2025_MES_719691_1
GE (FBD)/AF-T-34/2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naraina
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹98,000
Yes
6 Oct 2025
10 Jul 2025
4 Aug 2025
10 Jul 2025
31 Jul 2025
17 Jul 2025
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators complete all as specified and directed. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 2 above but 5 Amp socket outlet, independent.
All as per item No 2 above but on the same board.
All as per item No 2 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable.
All as per item No 2 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through PVC casing caping of ISI marked with fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators complete all as specified and directed. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 7 above but 5 Amp socket outlet, independent.
All as per item No 7 above but on the same board.
All as per item No 7 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly complete all as specified and directed.
S&F in replacement of switch piano type 5 amp SP one way ISI Marked complete all as specified and directed.
S&F in replacement of switch 15 Amps SP one way ISI Marked complete all as specified and directed.
S&F in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed.
S&F in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed.
S&F in replacement of stepped type electronic fan regulator flush type on the existing phenolic sheet etc complete all as specified and directed.
S&F in replacement for modular switches 6 amps single pole one way complete all as specified and directed.
S&F in replacement for modular sockets out let 6 amps 6 pin 2 module with shutter complete all as specified and as directed.
S&F in replacement for modular switches 16 Amps single pole one way complete all as specified and as directed.
S&Fin replacement modular socket out let 6-16 Amps 3 pin combined shuttered complete all as specified and directed.
S&F in replacement of stepped type electronic fan regulator modular complete all as specified and directed.
S&F in repair ceiling rose complete all as specified and as directed.
S&F in replacement of ding dong bell electric 230 volt AC complete all as specified and directed.
S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed..
S&F single pole blanking plate in the existing cover plate complete all as specified and as directed.
Supply and fix modular white cover plate with frame 3 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame 4 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame 6 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame 8 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 3 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 4 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 6 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 8 module ISI marked complete all as specified and as directed.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 4"x4" complete all as specified and as directed.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 7"x4" complete all as specified and as directed.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8"x10" complete all as specified and as directed.
S&F in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 20 Amps complete all as specified and directed.
M&L PVC insulated FRLS single core with strandard copper cable of size 6 Sqmm in two run and 6 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable acomplete all as specified and directed. NOTE :- 2 runs of 6 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
All as per item No 37 above but copper cable single core of size 4 Sqmm in two run with earth wire 4 Sqmm single run for continuity . NOTE :- 2 runs of 4 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
All as per item No 37 above but copper cable single core of size 2.5 Sqmm in two run with earth wire 2.5 Sqmm single run for continuity. NOTE :- 2 runs of 2.5 Sqmm cable and one run of 2.5 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
M&L PVC insulated FRLS single core with strandard copper cable of size 2.5 Sqmm in two run and 2.5 Sqmm one run for earth and drawing through ISI marked casing caping including taking down old UNSV cable acomplete all as specified and directed. NOTE :- 2 runs of 2.5 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and as directed.
Supply and fix in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 800 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and as directed.
M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed.
S&F in replacement wall mounting box type LED tube light fitting , extruded aluminium heat sink provided for efficient heat dissipation & Integrated electronic driver 1x20 watt comprising of strong jointless CRCA body complete with all accessories and complete all as specified and as directed.
M&L for Recess mounted 36/ 40 Watt high efficancy 2x2 recess LED flat panel with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and as directed.
Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries complete all as specified and as directed.
Supply and fixing in replacement of old unsv GI bracket made out of 32 mm bore,light grade 1.2 m long bent to shape suitable for street light fitting including MS flat clamp 50 x 6 mm 2 Nos for each bracket with nut & bolt complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and as directed.
S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and as directed. Note : - MCCB shall be measured and paid separately
S&F sheet metal enclosures DB Double door Verticle distribution type, 08 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and as directed. Note : - MCCB shall be measured and paid separately
S&F in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed.
S&F in replacement MCB DB SPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed.
S&F in replacement MCB DB SPN 6 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed.
S&F in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed.
S&F in replacement MCB DB SPN 12 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and as directed.
S&F in replacement of MCCB TPN 63Amps 16KA complete all as specified and directed.
S&F in replacement of MCCB TPN 125 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and as directed.
S&F in replacement of MCCB TPN 100 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 Amps 240 Volts."B" grade complete all as specified and directed.
S&F in repairs MCB,SP 40 Amps, 240 Volts."B" grade complete all as specified and directed.
S&F in repairs MCB SPN, 40 Amps, 240Volts ."B" grade complete all as specified and directed.
S&F in repairs MCB SPN, 63 Amps, 240Volts."B" grade complete all as specified and directed.
S&F in repairs MCB TPN, 63 to 100 Amps,415Volts ."B" grade complete all as specified and directed.
Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and as directed.
S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and as directed.
Supply and fix modular type gang box (3 module for one socket and one switche) suitable for 5/15amp 6pin including plate cover plastic sunken box etc including suitable size of switches and sockets complete all as specified and as directed.
Taking down storage water heater 25 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and as directed.
M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacity ISI Make as per sample complete all as specified and as directed.
M&L for replacement of heating element 1.5KW,Triangular/round type as per sample complete all as specified and as directed.
M&L for replacement of heating element 2 KW with complete assembly of any model and type as per site requirement /sample complete all as specified and as directed.
Material and Labour for disconnecting from electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly 6/9 holes with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as specified and as directed.
M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 16 SWG powder coated complete with all connected accessories suitably fitted with existing wall complete all as specified and as directed.
M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and as directed.
M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long (for hot and cold water inlet and outlet) having PTMT nuts with washer complete all as specified and as directed.
S & F in Replacement of bottom cover suitable cylindrical type geyser as per existing required as per site for 25 Ltrs capacity complete all as specified and as directed.
Dismantling and opening storage tank of geyser 25 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and as directed.
S & F in replacement of indication lamp red and green (pilit type ISI marked) for 25 Ltrs water heater complete all as specified and as directed.
Supply and fixing in replacement of PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitable for 650 volts grade complete all as specified and as directed.
S & F in replacement of glass wool in any capacity of geyser complete all as specified and as directed.
Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including servicing, greasing,oiling,replacing wornout bearing ,bush and refixing the same at site complete all as specified and as directed.
All as per item No 80 above but for Exhaust fan complete.
All as per item No 80 above but for wall/floor mounted fan .
Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and as directed.
All as per item No 83 above but for Exhaust fan 300 mm sweep.
All as per item No 83 above but for wall/floor mounted fan 450 mm sweep.
M&L Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
M&L for Replacement of old unserviceable fan blades, (ISI Marked), suitable for 1200mm sweep ceiling fan duly painted in white/brown by using spray gun method(fully furnished) complete all as specified and directed.
M&L for Repalcement of old unserviceable down rod of ceiling fan of dia 20mm bore "medium grade" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) dully painted in white/brown by using spray gun method (fully furnished) complete all as specified and directed.
Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor cable of size 0.5 sqmm,3 core cut to size of approx 0.30 metre from block of fan to ceiling rose complete all as specified and directed.
M&L for Replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grinding and welding work complete all as specified and directed.
M&L for Replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed.
M&L for Replacement of old unserviceable steel screw of size 5mm to 8mm (to be used for fixing of fan blade) complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, and accessories 230V, 1200/1400mm sweep with squirrel cage induction motor complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fix exhaust fan sweep 250 mm in replacement made up of sturdy engineering metal body complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed.
Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed.
Supply and fix Ventilation fan PVC (200 mm Sweep) with louvers and acessories complete all as specified and directed.
M&L for Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd (ISI marked) complete all as specified and directed.
M&L for Replacement of old unserviceable capacitor AC 400/415 volts 3.15 mfd (ISI marked) complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to and including earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe for watering and funnel, GI Pipe medium grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 complete all as specified and directed.
M & L in repairs earthing complete with galvanised steel earth plate electode 600 x 600 x 6.0 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & including galvanised steel wire 4.0 mm dia size means of nuts and bolt check nuts and washers of galvanised rion sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to earthing test point complete including testing filling of adquate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil upto 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.
M&L for making new hole of 150 mm dia and 3.0 mtr depth or excvation of earthing size 1.5x1.5x3.5 mtr one pit and supply and filling in micronite(bentonite) base earthing enhancement micronite compound (0.001 ohms mtr conductive grounding granuals 25 kg in each pit) and copper electorode rod 17.7 mm dia and 3 mtr long as per relavent IS and to achieving the desired earth result complete all as specified and as diercted by Engr-in-Charge. (Each earth pit shall include minimum 25 kg NABL Lab certified micronite aggregate and cement 12.5 kg for filling bore hole with water mixed in 1:2 ratio (two parts of micronite aggregate compound and one part of cement), so also achieve eath resistance below 1 ohm including PVC pit box with cover shall be deemed to be inclusive in the quoted rates. In case of non achieving of desired results the same shall be re-done by the contractor on his own cost.
M&L in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Supply and fix aluminium strip 25 mm x 4 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed.
Supply and fix copper strip 20mm x 3.15 mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips complete all as specified and directed.
Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long all as specified and directed.
S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed.
M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed,
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed.
M&L for Testing of exisiting earthing resistance with suitable digital Earth tester and recording the readings obtained and making the earthing good by pouring the salt water complete all as specified and directed.
Repairs to earth chambers by demolishing unserviceable earth chambers and fixing new chambers of PCC 1:3:6 type C1 as per electrical plate no.3 of SSR Part-I complete all as specified and directed.
Repairs to earth chamber cover by removing unserviceable earth chambers cover and fixing new cover all as specified and directed.
M&L for CI plate triangular with 500 mm long spike for writing earthing name and value complete all as specified and directed.
M&L for point wiring with single core FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in enamelled steel conduit suitable for flameproof switch/socket/LED Bulk Head ligh/Fluorescent LED fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush box of suitable size modular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed.(a) One light point controlled by one switch complete all as specified and directed.
Supply and fix Fluorescent LED tube light fitting 1 x 16/20W flameproof type made of Die cast aluminium alloy housing with heat resistant glass/heat resistant dome glass/extrenal reflector with CMRI certified LED FLameproof well glass luminaire for gas/vapour grtoup of IIA & IIB ans Zone 1 & IP65 protection etc. complete with all accessories prewired and including connecting up with three core twisted flexible copper conductor cable with suitable size all as directed.
Supply and fix Fluorescent LED tube light fitting 1 x 8 W flameproof type made of Die cast aluminium alloy housing with heat resistant glass/heat resistant dome glass/extrenal reflector with CMRI certified LED FLameproof well glass luminaire for gas/vapour grtoup of IIA & IIB ans Zone 1 & IP65 protection etc. complete with all accessories prewired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S & F flame proof exhaust fan 305 mm (12)" sweep heavy duty 1440 RPM, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.5 sqmm (16/0.2 mm) from ceiling rose to fan and connecting up with three core twisted flexible copper conductor cable with suitable size all as specified and as directed
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Suppply and fix flame proof switch socket & plug combined in LM 6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Taking up or downs DI pipes of size 80 mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Supply laying and testing of Ductile Iron pipes in replacement of unserviceable CI pipe of 80 mm bore with spigot and socket ends centrifugal cast, class K-7 as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches including taking down complete all as specified and directed.
Supply and fixing in replacement of unserviceable GI tubing medium grade with all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc including taking down complete all as specified and directed.
All as per item No 126 above but 100 mm dia.
All as per item No 126 above but 80 mm dia.
All as per item No 126 above but 50 mm dia.
All as per item No 126 above but 40 mm dia.
All as per item No 126 above but 25 mm dia.
All as per item No 126 above but 20 mm dia.
Supply and fix connected Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves complete all as specified and directed.
All as per item No 133 above but 50 mm dia.
All as per item No 133 above but 25 mm dia.
All as per item No 133 above but 20 mm dia.
All as per item No 133 above but 15 mm dia.
Taking out existing unserviceable/ broken / damaged CI sluice valve from its existing position and S&F CI sluice valve stainless steel, spindle CI body class –I, PN-1.6 ISI marked both end flanged and drilled and fixed by means of new nuts, bolts and washer including providing rubber gasket of suitable thickness of following sizes complete all as specified and directed.
All as per item No 138 above but 100 mm dia bore of pipe
All as per item No 138 above but 80 mm dia bore of pipe
All as per item No 138 above but 50 mm dia bore of pipe
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 100 mm dia complete all as specified and directed.
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 150 mm dia complete all as specified and directed.
S&F brass foot valve of size 80mm suction pipe complete all as specified and directed.
M&L for draining out sedimentation sludgy water from RCC Semi-Ground Sump 70,000Ltr capacity -01 nos incl scrapping out sticken forieign material from inner side of Semi UG sump walls/Ceiling by wire brush and removing excavated sedimentatation manually and depositing 50 mtr away fromSump and flushing out the floor with fresh water till satisfaction of Engineer in Charge providing two coats of white wash on old prepared surface cleaning of after completely draining out water from the tank.Writing of cleaning date on the tank complete all as specified and directed. Note : (i) The cost of the same shall be deemed included in the respective items. (ii) All T&P required for the cleaning of tanks / sumps will be arranged by the contractor.
M&L for draining out sedimentation sludgy water from RCC Under Ground Sump 30,000Ltr capacity -01 nos incl scrapping out sticken forieign material from inner side of UG sump walls/Ceiling by wire brush and removing excavated sedimentatation manually and depositing 50 mtr away fromSump and flushing out the floor with fresh water till satisfaction of Engineer in Charge providing two coats of white wash on old prepared surface cleaning of after completely draining out water from the tank.Writing of cleaning date on the tank complete all as specified and directed. Note : (i) The cost of the same shall be deemed included in the respective items. (ii) All T&P required for the cleaning of tanks / sumps will be arranged by the contractor
S&F, in replacement of fully automatic star delta submersible starter with short circuit protection in sheet metal enclousers suitable for 20HP , 415 Volt 50 Hz with over load protector and phase preventer and taking out old U/S starters of any type and any capacity complete all as specified and directed.
S&F, in replacement of fully automatic star delta submersible starter with short circuit protection in sheet metal enclousers suitable for 10HP , 415 Volt 50 Hz with over load protector and phase preventer and taking out old U/S starters of any type and any capacity complete all as specified and directed.
S&F in replacement of DOL starter for 10 HP with complete protection complete all as specified and directed.
M&L for removing all connections from existing starter suitable capacity of 20HP/10HP , Star Delta type starter, for repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the starter as per standard engineering pactice complete all as specified and directed. Note : Old U/S items will be provided against respective items separately.
Supply and fixing of overload relay suitable for 20HP/10HP fully automated start delta starter complete all as specified and directed.
Supply and fixing of phase preventer suitable for 20HP/10HP fully automated start delta starter complete all as specified and directed.
S & F pneumatic timer 0.1-60 seconds time delay,suitable for mounting in starter panel ,12.5 HP capacity,415 volts AC complete all as specified and directed.
S & F pneumatic timer 30-120 seconds star delta time delay model GIC complete all as specified and directed.
S & F thermal over load relay,5-15 Amps range,240-440 volts complete all as specified and directed.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 50 to 110 complete all as specified and directed.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 40 to 45 complete all as specified and directed.
Supply and fix in replacement amp meter digital type as per existing size and type complete all as specified and directed.
Supply and fix in replacement volt meter digital type as per existing size and type complete all as specified and directed.
S & F Volt Meter 0 to 500 Volts digital square type 4” complete all as specified and directed.
S & F Ammeter 0 to 200 Amps digital Square type 4” complete all as specified and directed.
S&F in repair CT 30/5 to 200/5 complete all as specified and directed.
S & F Indicating Lamp set of three (Red , Yellow & Blue) complete all as specified and directed.
Supply and fix in repairs Decrin dozing pump 100 PSI 40 GPD Capacity and testing complete all as specified and directed.
Supply and fix in replacement of circuit of speed of Dozing pump complete all as specified and directed.
Supply and fix in replacement of injector Nozzle of Decrin dozing pump complete all as specified and directed.
Supply and fix in replacement of Regulator Knob of dozing pump complete all as specified and directed.
Supply and fix in replacement of power cord of dozing pump 2 mtr long plug top 5 AMP 240 volt AC complete all as specified and directed.
M&L for "lifting and Lowering of any capacity" Submersible Pump Set of capacity 7.5 HP for repair/ Overhauling /rewinding /devolpment incl increasing the length of delivery pipe/or any other requiremwnt at site at tube well installation with man power/Chain Pulley arrangement including shifting to local workshop for repair and to bring back after repair at site including testing and commisioning complete all as specified and directed. Note :- Any minor part if required will be provided by contractor without any extra cost.
M & L for Dismantling and strip opening of burnt submersible pump of capacity 7.5HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commmisioning such as (i) Impeller GM . (ii) Distance bush SS.(iii) Guide Bush (iv) Neck ring gun metal (v) Impeller key (vi)Guide van (vii) Sand Guard including tranportation to local work shop etc complete all as specified and directed.
M & L for Dismantling and strip opening of burnt Booster pump motor of capacity upto 10 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commisioning including tranportation to local work shop etc complete all as specified and directed.
M & L for Dismantling and strip opening of burnt Booster pump motor of capacity upto 20 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commisioning including tranportation to local work shop etc complete all as specified and directed.
Supply and fixing in repair flat PVC insulated Sheathed, Copper conductor,4 sq mm ,3 core (flexible) cable,1100 Volts complete all as specified and directed.
Supply and fixing in repair flat PVC insulated Sheathed, Copper conductor,6 sq mm ,3 core (flexible) cable,1100 Volts complete all as specified and directed.
Attending Complaints by deploying sufficient labour for rectification of leakage of UG water pipe lines of size 200/150 mm bore of any description such as CI/DI/GI pipe line at any location including necessary excavation in any type of soil (approx 2 meter length,width 1.5 meter ,depth 1.5 meter) dewatering complete by using pump set as per site requirement, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material etc complete all as specified and as directed.
All as per item No 176 above but of size 100mm dia pipe line
All as per item No 176 above but of size 50/40 mm dia pipe line
All as per item No 176 above but of size 25/20 mm dia pipe line
Costruction of valve chamber in PCC 1:5:8 masonry built in CM(1:4) with MS covers 3 mm thick and locking arrangement including excavaton and earth works PCC (1;4;8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15 mm thick with Cm 1:4 painting with one coat of bituminous black paint on all steel surface or the following sizes chambers complete all as specified and directed :-
All as per item No 180 above 1350 mm x 1000 mm x 1200 mm internal dimension
All as per item No 180 above 900 mm x 900 mm x 1000 mm internal dimension
All as per item No 180 above 900 x 600 x 1000 mm internal dimension
Supply only Calcium based white to white free granular chlorination chemical decomposing at 177 C mol 112.98,Toxiicity oral rat LD 50 : 850 mg/kg in 45 Kg packing complete all as specified and directed. Make:Purichlor or equivalent product of other manufacturers.
Supply only Alum crystal super quality complete all as specified and directed.
S&F Water level Indicator for OH/UG tank, water level display wired sensor security system with alaram system having power input 230V, 50 Hz, including electrical cable for connection complete all as specified and directed.
Supply only chlorine test kit with PH colured sample complete with all testing fitment and OT solution in rexine box complete all as specified and directed.
M&L for chemical and bacteriological analysis of Raw water collected from all the pump house complete all as specified and directed.
M&L for chemical and bacteriological analysis of chlorinated water collected from distribution line complete all as specified and directed.
Disconnecting & dismantling of pump set from the foundation breaking the existing defective PCC foundation in any size, shape M&L for PCC 1:2:4 type B-2 using 12.5 mm graded aggregate for foundation of any size of motor pump set from 50 HP to 75 HP capacity pump set and fitting pumping set in position with base frame painted with synthetic enamel black paint complete all as specified and directed.
NAVYUG VYAPARI (BID ID -3368410)
M/S Parshant Associates (BID ID -3378637)
M/S Anand Enterprises (BID ID -3373018)
sheetal engineering (BID ID -3369322)
PARAS ENTERPRISES (BID ID -3375789)
Singh Associates (BID ID -3378253)
Vijeta Solutions (BID ID -3369127)
Surjit and Sons (BID ID -3369573)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .