Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹15.6 L Quoted ₹16.9 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹17.7 L+₹78,145 (4.61%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | ₹17.7 L+₹78,145 (4.61%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹19.2 L+₹2.3 L (13.5%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹19.2 L+₹2.3 L (13.5%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹19.3 L+₹2.4 L (14.2%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | ₹19.3 L+₹2.4 L (14.2%) | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹21.9 L+₹4.9 L (29.1%)Rejected-Finance | ₹21.9 L+₹4.9 L (29.1%) | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,200
Closing Date
14 Mar 2024, 6:00 pmClosed
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR / MAINT OF CEILING FANS, EXHAUST FANS, AIR CIRCULATORS , DESERT COOLERS AND CONNECTED ITEMS AT PATIALA MIL STN UNDER GE (N) PATIALA
2024_MES_643695_1
GE (N)/TOKEN-96/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹60,200
Yes
28 Mar 2024
22 Feb 2024
16 Mar 2024
22 Feb 2024
14 Mar 2024
7 Mar 2024
Amount
Dismantling of ceiling fan 1200 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of ceiling fan 1400 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of wall mounting/Cabin fan 380/400mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of industrial wall mounting air circulator fan 450/600mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of exhaust fan 380/450mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of exhaust fan 225/300 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed. Note for item No. 1.00 to 6.00 : It is the prime responsibility of EIC to ascertain the necessity of rewinding to a particular fan. Before handing over fan to the contractor, testing for winding shall be done in presence of EIC and all such fans shall be stored separately for subsequent repair from the contractor.
Supply and replacement of exhaust fan motor suitable for 225/230mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
Supply and replacement of exhaust fan motor suitable for 300mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
Supply and replacement of exhaust fan motor suitable for 380/450mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
Supply and replacement of industrial wall mounted fan motor suitable for 450/600mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
Opening up ceiling fan, exhaust fans, wall mounting/table fans, air circulator fans (any sweep, size or make) as kept unserviceable in E/M store yard for detection of defect and reassembling after cleaning, greasing and overhauling including replacement of split pins, body/blade screws and testing before depositing in store yard complete all as specified and directed. Note: Other spares necessary to be replaced shall be measured and paid for separately under following items of this schedule.
Supply and fix in replacement of Capacitor 2.5/3.15 mfd 230 Volts (+) 5 % dry type complete all as specified and directed. Make- TIBCON/ELCAP/'AD/TORCON)
Supply and fixing PVC capacitor assy two ways with fixing screws any type all as specified and directed
Supply and replacement of ball bearing for ceiling fans of any sweep/size/ any make complete all as specified and directed. Size of 6200,6201,6202,6203,6204 & size S-7/S-8 (Make of bearing : Make ABC/SKF/NBC. Note : Ball bearing shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included in quoted rates in this item.
Replacement of gun metal bush for ceiling fans, exhaust fans and cabins fans of any makes/size complete all as of specified and directed. Note : Bush shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included in quoted rate in this item. Note:- Cost of replacement of UNSV Shaft for exhaust fan of capacity 200/300mm sweep shall be included under this item.
Taking down and refixing of ceiling fan after supply and replacement of rubber reel of ceiling fan complete with ms split clamp two Nos, nuts and bolts complete all as specified and directed by Engr-in-charge.Note:-Contractor has to submit the certificate regarding serviceable condition of rubber reel, fan hook, clamp hook and split pin of ceiling fan.
Supply and replace fan regulator electronic, Piano type, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
Supply and replace fan regulator electronic, modular type as per sample, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
Replacement of Capacitor 4 mfd 230 Volts (+) 5 % dry type complete suitable for desert cooler all as specified and directed. Make- TIBCON/ELCAP/'AD/TORCON)
Replacement of ceiling fan blade(multipurpose type) suitable for 1200 mm sweep ceiling fan including nuts, washers etc complete all as specified and directed suitable for any make of fan. (white/Browm colour/as per site requirement).
Supply and connecting flexible copper wire 2 core Cable of size 23/0.0076, 0.5 sq mm (white colour) complete all as specified and directed.
Supply & fixing as in old/damaged body of Exhaust Fan made of steel properly painted with all fixtures make as same of motor and size upto 300 mm complete all as specified and directed.
Supply & fixing as in old/damaged body of Exhaust Fan made of steel properly painted with all fixtures make as same of motor and size upto 380/450 mm complete all as specified and directed.
Supply & fixing as in old/damaged body of wall mounted Fan made of steel properly painted with all fixtures make as same of motor and size upto 450/600 mm all as directed by Engineer-in-Charge.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size 380mm/450mm all as directed by Engineer-in-Charge.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size 300mm all as directed by Engineer-in-Charge.
S&F in Replacement of PVC canopy (upper/bottom) for ceiling fan of any make and size all as directed by Engineer-in-Charge.
Supply & fixing down rod for ceiling fans made out of MS pipe 15mm bore medium grade 60 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint all as directed by Engr-in-Charge
Supply & fixing down rod for ceiling fans made out of MS pipe 15mm bore medium grade 1.2 m long duly threaded, holes drilled and spray painted with synthetic enamel paint all as directed by Engr-in-Charge
Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour) including scrapping existing paint and incl writing MES Number with black paint all as directed by Engr-in-Charge.
Spray painting on outside body of the exhaust fan incl blades any size with synthetic enamel paint (smoke gray colour) including scrapping existing paint and incl writing MES Number with black paint all as directed.
Supply and fix ceiling fan box round cover plate size 6 inch complete all as specified and directed by Engr-in-chrge.
M & L for two coat of super enamelled paint over a coat of red oxide primer for Desert cooler of any size/ make and matching the same on the exterior colour by metal paste/putty complete all as specified and directed.
Dismantling of desert cooler motor,(any make and type,taking out rotor removing all coils(burnt and alive)rewinding all the coils with suitable size super enamled copper wire(ISI marked) including all packing materials,insulating materials,varnishing greasing oils,reassembling,split pins, body blade screw and testing on full speed as per the direction of EIC complete all as specified and directed . Note: Cost of Replacement of UNSV gun metal bush and shaft for desert cooler shall be included under this item
Supply and fixing in replacement submersible PVC body Tulu pump suitable for desert cooler of any size. Make- KHAITAN/COOL HOME/CG
Supply and fixing in replacement wood wool padding for desert coolers on all three sides ( for any size and type of cooler) all as directed.
Supply and fixing flexible PVC transparent 15mm bore pipe set comprising one pipe from pump to PVC junction and 3 Nos short pieces of pipe from junction to shutter all as specified and directed.
Supply and replacement of fan motor 1/10HP capacity suitable for desert cooler complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
Supply and replacement of Desert Cooler body duly spray painted made out of 22 gauge MS sheet complete with front grill side shutters, control switch piano type 5 Amp speed regulator including lamp, wiring with suitable copper cable complete all as specified and directed.
Supply and fixing in replacement of PVC front grill (Jali) of suitable size of desert cooler all as specified and directed.
Supply and fix as in replacement flexible copper conductor cable 3 core, PVC insulated of size 70/.0076 and connected electrically to any electric devices/of any capacity size type & make etc complete all as specified and directed.Make:KEI,Plaza,Kalinga,Havells
Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz all as specified and directed.
S & F fan (PVC or metal) blade of suitable size for desert cooler complete all as specified and directed.
S & F Top Plug 3 Pin 5 Amps 230 Volts Make: Anchor/Plaza/Kalinga/Polycab
S & F metallic frame with set of 4 legs as per model suitable for fixing/mounting fan motor of desert cooler with nuts, bolts, rubber etc., complete all as specified and directed.
S&F in replacement of PVC water distributor and elbow for desert cooler ( for any type and size of desert cooler) all as directed and specified
Supply and replacement of PTMT Ball Valve suitable for 15 mm bore pipe complete suitable for desert cooler complete all as directed.
Supply and fix fresh air fan (suitable for bathroom/toilets) AC single phase 230/240 volt made of sturdy Engineering plastic complete with louvers shutter, 50 Hz, RPM 1200, Copper winding of sweep 225/230 mm,electrically connecting with twisted three core PVC insulted unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to PVC Exhaust fan complete all as specified and directed by Engineer-in-Charge.
AGGARWAL & CO
SWAMI ENGINEERS
Mohinder Pal and Sons
m/s s.n. builders
FAVOURITE ENGINEERS
gurchan singh & sons.
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .