Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹39.8 L+₹8.1 L (25.4%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category. | |
| 4 | Rejected-Technical HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | - | Rejected-Technical Not enlisted in appropriate category. | |
| 5 | Rejected-Technical NIL | - | Rejected-Technical Not enlisted in appropriate category. |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
28 Oct 2020, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI - 834009
REPAIR MAINT OF HT OVER HEAD LINE VCB TRANSFORMER HT POLE PAINTING AND HT CABLE WITH CONNECTED WORKS AT MILY STN GAYA UNDER GE GAYA
2020_MES_381755_1
80599/1311/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Gaya
Class D Category b(iii)
6 documents required · 6 mandatory
₹500
Yes
GE Gaya
₹60,000
Yes
10 Mar 2021
29 Sept 2020
30 Oct 2020
29 Sept 2020
28 Oct 2020
14 Oct 2020
Amount
Disconnecting and taking out existing HT 11 KV VCBs of Make : Areva situated at 33 KV Sub Stn, from housing and cleaning, rubbing, oiling, greasing and overhauling the mechanical parts and servicing of 11 KV indoor VCB, checking of quality of vaccum interrupter, insulation resistance, static connection resistance testing(IR value, Ratio test, polarity test) and connection verfification of 11 KV current transformer set of three) by PRIMARY INJECTION KIT and testing and calibration of relay (set of two over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs, replacement of unserviceable parts and making serviciable condition complete all as specified and directed by Engr-in-Charge.
Disconnecting and taking out existing HT 11 KV VCBs of Make : Crompton situated at MH Power House, from housing and cleaning, rubbing, oiling, greasing and overhauling the mechanical parts and servicing of 11 KV indoor incomer cum outgoing VCB, checking of quality of vaccum interrupter, insulation resistance, static connection resistance testing (IR value, Ratio test, polarity test) and connection verfification of 11 KV current transformer set of three) by PRIMARY INJECTION KIT and testing and calibration of relay (set of two over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs, replacement of faulty materials Buffer, Breaker Bushings, Neutral Close Switch, Tripping/closing Coil, Pin for bearing, Shunt Trip Coil, All LED indication lamps, Spring Charge Motorand checking internal wiring and making serviceable condition complete all as specified and directed by Engr-in-Charge.
Taking down carefully the burnt transformer of any size from 1.0 metre height PCC foundation by crane after disconnection all HT/LT electric connection and body, neutral earth connection complete and brought to MES store or trade for repair complete all as specified and directed by Engr in charge
All as per item No 04 here in above but from 2 pole structure of a hight of 3.0 Mtr complete all as specified and directed by Engr in charge
Dismantling the transformer complete by unscrewing all nuts & bolts top-cover and disconnecting all connection to LV bushing and HV bushing and lifting the core complete from oil tank, cleaning the core complete and testing to find out burnt core of the transformer complete all as specified and directed by Engr in charge. Note:-Demolished items are departmental propert and contractor have to deposit to MES store
M&L for re-winding the burnt core 63 KVA, 33KV / 415 V transformer by new super enamelled copper wire of same gauge as existing one by considering the same phase displacement and using new stallay sheet of 0.35mm thick containing silcon and complete the winding by heating and cooling with burnishing, testing insulation resistance of winding complete for re-fixing in old position. Note : (i) commissioning & testing shall be done up to the entire satisfaction of Engr-in-charge. (ii) Re-filling of new transformer oil, new busher and gasket will be measured under separate items
M&L for Re-winding the burnt core 100 KVA transformer by new super enamelled copper wire of same gauge as existing one by considering the same phase displacement and using new stallay sheet of 0.35 mm thick containing silcon and complete the winding by heating and cooling with burnishing, testing insulation resistance of winding complete for re-fixing in old position . Note: (i) commissioning & testing shall be done up to the entire satisfaction of Engr-in-Charge . (ii) Rc-filling of new transformer oil, new busher and gasket will be measured under separate items.
All as per item No 08 here in above but 200 KVA to 315 KVA complete all as specified and directed by Engr in charge
All as per item No 08 here in above but 630 /625KVA complete all as specified and directed by Engr in charge
M&L for Re-install transformer at site of any size with all LT and HT connection with body earthing and neutral earthing connection complete all as specified and as directed.
Supply & fixing gasket set of synthetic rubberized cork sheet 5 mm thick for transformer top lid cover,LT & HT terminal bushing suitable for Transfoormer of capacity 63 KVA/65KVA/100KVA complete all as specified and as directed by Engr in charge
All as per item No 12 here in above but125//160/250 KVA complete all as specified and directed by Engr in charge
All as per item No 12 here in above but 300/315/400 KVA complete all as specified and directed by Engr in charge
All as per item No 12 here in above but 630/625 KVA complete all as specified and directed by Engr in charge
All as per item No 12 here in before but 1 MVA complete all as specified and directed by Engr in charge
M&L for Painting of transformer after cleaning the body surface of transformer by rubing with emery paper to remove oil strains ,dust etcand applying two coat of synthetic enamel paintby spray paint incl writing SM/MES no,capacity of transformerof capacity 63 KVA/65KVA/100KVA complete all as specified and as directed by Engr in charge
All as per item No 17 here in above but 125/250/160 KVA complete all as specified and directed by Engr in charge
All as per item No 17 here in above but 315/300/400 KVA complete all as specified and directed by Engr in charge
All as per item No 17 here in above but 630/625 KVA complete all as specified and directed by Engr in charge
All as per item No 17 here in above but 1 MVA complete all as specified and directed by Engr in charge
M&L for dehydration /filteration of transformer oil by means of centrifugalfilteration plant to achieved the specified dielectric strength upto 45 KV at 4 mm gap in existing possesion of transformer of any capacity and transformer oil for toping up at various sub station complete all as specified and directed by Engr in charge
Supply only Transformer oil of approved quality as per IS having dielectric strength of 40-60 KV in 2.5 mm gap for filling in transformer or for toping up after dehydration complete all as specified and as directed.by Engr in charge . Make: Castrol/power oil/Gulf Note- 200 Ltrs drum must be company sealed without company sealed drum not accepted.
S&F in replacement suitable silica gel complete suitable for any capacity/model of transformer to air column of conservator tank complete all as specified and directed.
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and exc. 1.5metre but not exc 3.0 metre deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil. completed all as specified and directed.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point. completed all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thisckness shall only be considered for payment.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mmx230mmx50mm over sand cushioning for protection of cable complete all as per specified and directed.
Dismantling of old rusted steel continuous earth wire and removal from site complete all as directed.
Supply and fixing steel continuous earth wire galvanized steel wire and cradle guard 3.15 or 4 mm dia, complete all as per specified and directed.
Dismantling of old ACSR conductor of any size and removal from site. completed all as specified and directed.
Supply and Fixing ACSR conductor on HT poles including stringing and fixing in position and binding to insulators and jumpers, complete all as specified and directed.
Dismantling and taking down cross arms of MS channel or angle sections, clamps, nut and bolt, washers, back plate of any size/shape complete and removal from site. completed all as specified and directed.
Supply and fixing on HT pole cross arms, bracing supports clamps from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size complete as directed including preparation of surface and painting two coats of aluminium paint over a coat of red oxide primer. completed all as specified and directed.
Dismantling old unserviceable stay assembly complete including necessary excavation and demolition of concrete and removal from site. completed all as specified and directed.
Supply and fixing on HT pole stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 20 mm dia including loop insulator suitable for 11 KV (size 90x140 mm) with clearance of hole 25.5mm and MS stay plate size 300 x 300 x 6mm, stay clamps etc completed all as specified and directed.
Dismantling of unserviceable insulators of any type/size and removal from site completed all as specified and directed..
Supply and fixing pin type porcelain, vitreous, white, brown or green insulators including galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts, 150 mm height 150 mm dia including section of straps of 38x5 mm size 20 mm dia of bolts, nuts & washers for 11000 volts grade. completed all as specified and directed.
Supply and fixing disc type insulator, porcelain, vitreous white, brown or green insulators for working pressure 11000 volt of 145 mm height 255 mm dia ball and socket type 'Two -in -series' asssembly for tension with tension clamp for conductors including bolts, nuts & washers.
All as per item No 41 here- in-before, single disc assembly. completed all as specified and directed.
Dismantling of unserviceable steel tabular poles any size and removal from site. completed all as specified and directed.
Supplying, transporting and erecting in position steel tubular swaged poles 410-SP-55 type, 11.00 M long complete with mild steel base plate, CI finial taper , bolts, nuts and washers etc. including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Dismantling of unserviceable air break gang operated switch 11000 volts grade from overhead HT line structure vertical/horizontal mounted including insulators and operating mechanism complete all as specified and directed.
Supply and fixing including testing switch air break triple pole mechanically operated, mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating upto 200 Amps, 11000 volt grade completed all as specified and directed.
Supply and fixing including testing switch air break triple pole mechanically operated, mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating upto 400 Amps, 11000 volt grade complete all as specified.
Dismantling unserviceable Lightening Arrestors including insulators, 33000/11000 volts grade from poles and removal from site. completed all as specified and directed.
M & L for Lightening arrestors Expulsion type complete with all fittings,Transmission Class,Discharge Capacity 65 Kilo Amps,11000 completed all as specified and directed.Volts.Make:Oblum/Alstom/
M & L for Lightening arrestors Expulsion type complete with all fittings,Transmission Class,Discharge Capacity 65 Kilo Amps, 33000 completed all as specified and directed.Volts.Make:Oblum/Alstom/
Taking out unserviceable HT UG cable of 11/33 KV grade, any size duly finding of fault from trenches, pole, road, duct etc including necessary joints, unserviceable fittings and pipes etc completed all as specified and directed.
Supply and laying XLPE insulted, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty, with aluminium conductor 11000 volts grade, cross sectional area 95 sq mm, 3core including provision of cable path indicator at every 50 Metre distance of cable complete all as per specified and directed.
Supply and laying XLPE insulted, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty, with aluminium conductor 11000 volts grade, cross sectional area 120 sq mm, 3core including provision of cable path indicator at every 50 Metre distance of cable complete all as per specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor tremination (End Joint) heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm to 120 sqmm including taking down old joint completed all as specified and directed. Make : Dension/MS-Seal/Fontech. .
S&F cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm to 120 sqmm including taking down old joint completed all as specified and directed. Make : Dension/MS-Seal/Fontech. .
Material and labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut bolt and washers incl taking down old pipe completed all as specified and directed.
Boring under road and foot path for inserting 80 mm bore GI tubing for drawing UG cable, complete all as per specified and directed.
Labour required for trimming / cutting of tree branches/long bushes/bambooes(of any girth), touching / obstructing the over head HT lines at places so as to keep minimum 1.50M mtr clearance all around the lines and disposal thereof to not exceeding 100 mtr distance after taking proper electric shut down from concerned staff complete all as specified and directed.( Note :- Linear length centre to centre of the poles shall only be measured ).
Labour required for re-stretching/ restringing of existing loosed / sagged ACSR over head HT conductor of any type and size including supply and binding wire/aluminum tape of required size, opening from insulators as fixed on pole after taking proper electric shut down from concerned staff including taking down unserviceable conductor from OH line and proper binding with additional conductor and restringing on line, complete all as directed by Engineer-in charge. (Note for Supply only ACSR conductor shall be measured and paid separately.)
M&L preparation of old painted surfaces of HT Steel tubular poles complete and applying two coats of alluminimum paint on the pole including writing the pole No with black enameled paint of size 70 mm wide and 100 mm height and Top(cross arm, bracket) of pole red enameled paint and bottom from ground (3 feet)of pole black enameled paint complete all as specified and directed by Engineer-in-Charge.
M&L provision for detection of 11 KV HT Cable Fault through finding and fault locating high voltage moble machine to locate the fault in 11 KV HT cable and find out exact location of fault all as specified and directed. Note : (i) The item includes transportation, charging machine upto detecting fault at time. (ii) HT cable joint, necessary excavation & earth work complete will measured and paid seprately against respective items of the schedule.
Supply, installation, testing and commissioning for replacement of 110V/30V DC power pack including internal connection from PT, necessary provision for mounting arrangement inside the VCB panel all etc complete as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning for replacement of 110V/24V DC power pack including internal connection from PT, necessary provision for mounting arrangement inside the VCB panel all etc complete as specified and directed by Engr-in-charge.
Supply, installation, testing and commissioning for replacement of 110V/110V DC power pack including internal connection from PT, necessary provision for mounting arrangement inside the VCB panel all etc complete as specified and directed by Engr-in-charge.
Supply and fixing of HT overhead lines on existing poles with XLPE insulated aerial bunched cable 3 Core x 95 Sqmm with guard wire with connecting fixing accessories like hook, end hook, all etc complete as specified and directed by Engr-in-charge. Make : Kalinga or its equivalent
Raj Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .