| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Being lowest tender |
| 2 | L2₹1.7 Cr+₹17.0 L (11.5%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹1.7 Cr+₹17.0 L (11.5%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹1.8 Cr+₹34.0 L (23.0%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.8 Cr+₹34.0 L (23.0%) | L3 | Rejected-Finance Higher than lowest tender |
| 4 | L4₹1.9 Cr+₹43.5 L (29.4%)Rejected-Finance 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | ₹1.9 Cr+₹43.5 L (29.4%) | L4 | Rejected-Finance Higher than lowest tender |
| 5 | L5₹2.3 Cr+₹80.1 L (54.1%)Rejected-Finance | ₹2.3 Cr+₹80.1 L (54.1%) | L5 | Rejected-Finance Higher than lowest tender |
Tender Value
₹1.7 Cr
EMD Value
₹2.4 L
Closing Date
21 Jul 2020, 6:00 pmClosed
CE KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
PROVN OF ONE DU FOR LT GEN AT PANAGARH MIL STN UNDER MAP PH-II
2020_MES_341235_1
89013/E8
Open Tender
Civil Works
Works
550 days
GE (P) PANAGARH
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (P) PANAGARH
₹2.4 L
Yes
8 Oct 2020
27 Apr 2020
22 Jul 2020
27 Apr 2020
21 Jul 2020
7 Jul 2020
Amount
Lumpsum price worked out by the tenderer/ bidder for BUILDING WORKS as listed in Schedule ‘A’ Part-I.
Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATION as listed in Schedule ‘A’ Part-II.
Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III.
Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV.
Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V.
Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI.
Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII.
Lumpsum price worked out by the tenderer/ bidder for COMPOUND WALL & GATE as listed in Schedule ‘A’ Part-VIII.
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX.
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-X.
Lumpsum price worked out by the tenderer/ bidder for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XI.
Schedule ‘A’ Part-XII (MISCELLANEOUS ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
(INTERNAL ELECTRIFICATION) Material and labour for point wiring for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multi stranded conductor 1100 volts grade controlled by one number one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multi strand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including concealed PVC conduit complete all suitable for modular electrical accessories all as specified and as directed by the Engineer-in-Charge. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. All modular accessories to be measured and paid for separately (Light/fan/call bell) and power circuit and 5A socket circuit, DBs should be separate) (Necessary wiring for cupboard lighting should be made as directed)
All as per item No 12.01 here-in-before but one light point controlled two way switch with 1.5 sqmm cable complete as specified and directed.
All as per item No 12.01 here-in-before but one call bell point controlled by one way switch with 1.5 sqmm cable complete as specified and directed. (Note: - all call bell point wiring should be terminated to servant Qtr/ kitchen/ ADC room as required by the user with necessary indication board and reset switch/push button).
All as per item No 12.01 here-in-before but for 5 pin 6 Amps socket outlet on the independent board with 1.5 sqmm cable complete as specified and directed.
All as per item No 12.01 here-in-before but for one 5 pin 6/16 Amps socket outlet on independent board with 4 Sqmm PVC insulated unsheathed copper cable multi stranded conductor 1100 volts grade and 2.5 sqmm copper conductor cable as earth continuity conductor complete as directed.
M&L for blank plate.
M&L for GI box 8 module.
Supply and fixing of LED tube light fittings 20 W, 4 feet length with all necessary connection and fixing arrangements with the following specifications: - (This fitting are for Kitchen/Servant/ADC room Bathroom etc) (i) System Watts/lumens: - Max 20 W/Total system lumen not less than 2800 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be struct structured in the same sequence.
Supply and fix surface & wall mounted LED batten 2 feet with 1x10 w indoor decorative luminaries with and including Electronic driver and 1 x10 Watt LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (This fitting are for bathroom/toilets /dressing room/store room/ or any others small size room) (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1400 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence
Supply and fix surface mounted LED wall bracket fittings with 6 w indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (Switch of this type of one lamp should be provided beside of Bed at each bedroom which will work as night lamp) (wall brackets are for bedroom/dining/living/ office only) (i) System Watts/lumens: - Max 06 W/Total system lumen not less than 840 Lm. (ii) Housing: - Extruded olycarbonate. (iii) IP rating: - IP 20. (iv) Front/top cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt.(ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life:- Not less than 25000 hrs of operation.(xii) Optics:- Designed for optimum light distribution. (xiii) Control gear:- Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating vlotage 180-270V Ac, 50 Hz (xiv) Surage protection:- Inbuilt surage protection minimum 2KV (xv) Heat sink:- As per OEM's design Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence
Supply and fix wall mounted adjustable angle LED focus/spot light 6/9 watt indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (for focusing on the portait/photos) (i) System Watts/lumens: - Max 9 W/Total system lumen not less than 1260 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence.
Supply and fix surface mounted LED mirror light 10 watt indoor luminaries with and including Electronic driver and LED lamp, pre-wired including necessary electric connection from ceiling rose to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 10 W/Total system lumen not less than 1400 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be structed in the same sequence.
Supply and fixing of LED panel on ceiling recessed mounted 2'X2' 36/40W, complete with inbuilt driver all connection and all fixing arrangements as specified below: - (This light is for bedroom/dining room/office living room) (i) System Watts/lumens: - Max 40W/Total system lumen not less than 5600 Lm.(ii) Housing: - Extruded polycarbonate. (iii) IP rating: - IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy (lm/Watt): - Not less than 140 Lm/watt. (ix) Colour temperature: - Not less than 5700 K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2 KV. (xv) Heat sink: - As per OEM's design. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be struct in the same sequence.
Supply and fixing of 50W halogen light with reflector complete with connection and fixing arrangements. (This light is for cupboard self for warm-up/illumination and dehumidification of cupboard)
M&L for Brush less DC (BLDC) ceiling fan with the following specifications:- (i) Motor: - Brushless DC 32 W, with operating voltage 140V-240V AC, 50 Hz. (ii) Max RPM: - 360 RPM. (iii) Sweep: - 1200mm. (iv) Colour:- White. (v) Remote control operated. (vi) 5 STAR energy saving rating
M&L for exhaust fan 300mm sweep with metalic blades flush mounting, Square type body case, operated on 230V, single phase Ac, 50 Hz complete with connection.
M&L for exhaust fan 250mm sweep with polycarbonate blade with louvers, flush mounting round / square type body case, operated on 230 V single phase, AC, 50 HZ supply complete with connections.
Supply and fixing distribution board (DB) SPN 12 ways, with bus bar 200A rating 230 Volts double door, recessed with wall surfaces by chase cutt9ing and making good surfaces of wall complete all as specified and as directed by the Engineer-in-Charge. (All circuit should be separate for light and power and separate DB should use for light and power).
Supply and fixing distribution board (DB) SPN 8 ways, with bus bar 200A rating 230 Volts double door, recessed with wall surfaces by chase cutt9ing and making good surfaces of wall complete all as specified and as directed by the Engineer-in-Charge. (All circuit should be separate for light and power and separate DB should use for light and power).
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Meter deep below normal ground level) with top edge of plate not less than 1.5 Meter below normal ground level connected to GI wire 4mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthwork, supplying and laying charcoal dust, common salt PCC 1:2:4 type CI chamber and MS angle iron frame 40x40x3mm RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20 mm dia GI pipe light graded for watering all as shown in drawing and connected to earth test point including testing complete all as specified and directed .
M&L for PVC Concealed conduit only with necessary junctionbox and accessories 20mm for TV and telephone cable with all cutting and finishing work.
M&L for tamper proof electronic energy meter, 3 phase AC, 440 Volts, 50 Hz, with accuracy class 1.0 with LED indicator presence for each phase, high surge withstand capacity upto 8KV polycarbonate enclosure, Anti tamper proof, 20-60 Amps rating with RS 232/ RS 485 communication port with and including necessary sheet metal meter box all as directed at site.
M&L for MCB SPN 40A, 230V, 50Hz, computable for DIN rail “C” series complete with connection.
M&L for MCB SPN 20A, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SPN 10A, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SP 6A, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SP 10A, 230V, 50Hz, computable for DIN rail “C” series complete with connection
M&L for MCB SP 20A, 230V, 50Hz, computable for DIN rail “C” series complete with connection
Supply and fix metal plug & socket enclosure with MCB 20A
Supply and fix sub-main (3 phase, neutral and earth) wiring with PVC insulated & unsheathed (4X4 Sqmm and 2X4.0) single core multi stranded 1100 Volt grade PVC insulated & unsheathed copper conductor cable (FRLS), drawn through PVC concealed conduit all as specified and as directed by the Engineer-in-Charge. Note : 4 runs of 4 Sqmm and two run of 4.0 Sqmm earth cable shall measured as one length (for AC plug and socket)
Supply and fix sub-main (3 phase, neutral and earth) wiring with PVC insulated & unsheathed (4X6 Sqmm and 2X6) single core multi stranded 1100 Volt grade PVC insulated & unsheathed copper conductor cable (FRLS), drawn through PVC concealed conduit all as specified and as directed by the Engineer-in-Charge. Note : 4 runs of 6 Sqmm and two run of 6 Sqmm earth cable shall measured as one length.
(INTERNAL WATER SUPPLY). S&F stop valves fancy type, chromium plated with long shank and cup bore of pipe 15 mm.Concealed type ( Make- the item shall be of continental model of Jaquar / Ocean model of Cera/ Essco model of Marc)
S&F Angular stop cock with wall flange screwed both ends for iron pipe or for unions fancy type, chromium plated with long shank and cup bore of pipe 15 mm. (Make- the item shall be of continental model of Jaquar / Floral model of Cera/ Essco model of Marc)
S&F Pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure long screwed shanks and fly nuts screwed for iron pipe. Bore of pipe 15mm fancy type. (Make- the item shall be of continental model of Jaquar / Floral model of Cera/ Essco model of Marc)
S&F Bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe fancy type chromium plated. Bore of pipe 15mm. (Make- the item shall be of continental model of Jaquar / Floral model of Cera/ Essco model of Marc)
S&F Sink cock with regular swinging spout (wall Mounted Madel)with flange fancy type chromium plated, screwed for iron pipe. Bore of pipe 15mm. (Make- the item shall be of continental model of Jaquar / Floral model of Cera/ Essco model of Marc)
S&F Hand Shower( Health Faucet) with 8 mm dia,1.2 m long Flexible Tube& wall Hook with NVR( black flow Prevented) (Make- JAQUAR / Cera/Marc)
S&F JET Spray fixed to EWC . (Make- JAQUAR / Cera/Marc)
S&F Wall Mixer with provision for overhead shower with 115 mm long bend pipe on upper side, connecting legs& wall flanges (Make- the item shall be of Fusion model of Jaquar / Mist model of Cera/ Nacksh model of Marc)
S&F Corner Glass Shelf ( With Bracket) (Make- JAQUAR / Cera/Marc)
S&F Overhead Shower 140 mm dia Round shape Multi Flow with air effect ( ABS Body& Face Plate chrome plated) with Rubit cleaning system. (Make- JAQUAR / Cera/Marc)
S&F Soap Dish ( Chromium plated)Make- JAQUAR Model No-AQN-7731) /KOHLERor Equivalent
(External Water Supply) M&L for cutting or drilling of existing pipe line any size upto 200 mm dia for making new connection by way of insertion of suitable size tee or ferrule with all necessary connected items etc.
(External Electric Supply) S&F LED 18/20 watt LED post top decorative light for 360 degree indirect light distribution having IP65 degree of protection, with glare free optical diffuser etc complete with all accessories and connecting up with twin core twisted copper cable of suitable size all as directed at site.
Supply and fixing LED Bollard for landscape lighting 9/10 W ,IP-65,AC 230V 50 Hz,complete with housing,fixing arrangement on pcc base ,electrical connection all as directed.
Supply & Fixing junction box of size 200mm x 160mm x 98mm or nearest higher size made of polycarbonate with IP 65 degree of protection (K 8250), dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with heat treated bakelite terminals block and PVC Glands for cable entry and fixed to pole with suitable size FI clamp 20x3mm, nuts, bolts and washers, complete all as specified and directed.
M&L PVC Conduit 20 mm bore with necessary clamps for running of cable from junction box to street light fittings.
Supply, laying and testing PVC insulated, PVC sheathed cable unarmoured with stranded copper conductor of size 1.5 sqm, 3 core 1100 volts grade ( For street light connection from junction box to light).
M&L earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 meter below normal ground level, the earth plate surrounded by a mixture of charcoal dust and salt to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returning filling in and removal of surplus spoil up to 50 mtr including GI wire 4 mm dia bolted and riveted to earth plate at one end in and connected to continuous GI earth wire encased in and including 15 mm GI light grade pipe with all fittings from top edge of earth plate complete as specified and as shown in electrical plate no 5 including testing on completion.
M&L earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 meter below normal ground level, the earth plate surrounded by a mixture of charcoal dust and salt to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returning filling in and removal of surplus spoil up to 50 mtr including GI earth strip 32x6 mm bolted and riveted to earth plate at one end in and connected to continuous GI earth strip encased in and including 40 mm GI light grade pipe with all fittings from top edge of earth plate complete as specified and as shown in electrical plate no 5 including testing on completion.
Supply and fixing of all in one integrated solar hybrid street light ,with solar PV modules ,Lithium Ion mainantance free batteries and LED street light all in one unit with occupancy sensor feature complete with following specification all as specified and as directed (i) System Watts/lumens:-Max 12 W/Total system lumen not less than 2000 Lumens (ii) Housing: Extruded high grade aluminium die cast (iii) IP rating :IP 65 (iv) Front cover :Acrylic/polycarbonate cover (v) Mounting: suitable for bracket mounting and flexiblility of angle adjustment (vi) Finish:- Smooth finish (vii) Lamp:- High bright LED (viii) System efficancy (Lm/watt):- Not less than 175 lumens/watt (ix) Colour temperature:-Not less than 5700 K (x) Colour rendering index(CRI):- Not less than 60 (xi) Guaranteed life:- not less than 50000 Hrs of operation (xii) Optics:- Designed for optimum light distribution (xiii) Control Gear:- Inbuilt electronic driver with factory configured for LED load and P/R sensor with dimming profile ,smart self diagnosis feature with LED indicator ,along with battery charging and deep discharger indicator ,intrigated microcontroller based MPPT charger and driver for main supply and solar charging ,motion sensor ,PIR sensor, switch On/Off indicator with the standard operation voltage 180-270 V Ac,50 Hz (xiv) Surge protection:- inbuilt surge protection minimum 2 Kv (xv) Heat sink :- As per OEMs design (xvi) Battery:- Lithium Ferro phosphate battery (LiFePO4) with minimum 256Wh capacity 12V DC (xvii) Solar module shall be 12 V ,35 Wp mono crystalline with 17 % efficancy
Design, Supply, Installation, testing and commissioning of Wind and Solar Hybrid Energy System, based on modular, scalable, distributed renewable energy system designed and optimized for ON Grid installations, utilizing low profile vertical axis wind turbines (VAWT) mounted on a single base and solar panel and inverter complete with the following specifications:- Performance advantages:- (i) Root, top wind and solar Hybrid Energy System (ii) Stable 24 hrs power generation capability (iii) Mechanical breaking of high speed winds beyond 18.5 meters per second (iv) Appropriate for On Grid application (v) Online tool for power generation monitoring (vi) Power generation starting at 2m/Sec wind speed Technical Features:- (i) Low profile vertical axis sabonius wind turbines, cut-in speed 2m/Sec and Cut-out wind speed 18.5m/Sec (ii) Scalable to user defined KW need (iii) Integrated Maximum Power Point Tracking (MPPT) (iv) (MPPT) with smart bus logic control technology - 48V DC (v) Easy assembly and maintenance (vi) Temperature sensing electronics for thermal protection (vii) Able to with stand temp ranges form -30 C to 50 C (viii) Easy to mount on an stricture (ix) Ballasted or roof penetration structure. Technicla Details & Specifications:- (i) Dimensions : - Approximately - Length - 3100mm, width- 2555mm, height- 1900mm (dimension should be within the range of + 10% of the indicated dimension) (ii) Weight: - Approximately 250-300 Kgs (iii) Cover materials: - UV Resistant HDPE (iv) Frame:- Galvanized G-90 Steel or aluminium (v) Electrical enclosure rating:- IP 53 (vi) Electrical connection :- On Board Batter Charge controller with Grid tied Inverter (vii) Wind generator type :- Permanent magnet axial Gap or equivalent (viii) Guaranteed life: - 25 Years (ix) Wind component Max power output :- 1000W @ 16-18m/Sec (x) Max DC voltages: - As per system design (xi) Max solar power out put :- 150W (xii) Max solar panel voltage : - as per system design (xiii) Grid synchronisation valtage: - 415V, AC 50 Hz, 3 Phase. (xiv) Solar Panels:- As per MNRE approved and guidelines (xv) Note:- All electrical connecition required for paralled operation of two independent units and evacuation of power from proposed location at roof top the building to main distribution of the building shall be deemed to be inclusive in the unit rate quoted. Make : - "Wind stream technology, Model - Solar Mill SM-6P or equivalent of other make.
S&F brackets/arms suitable for street light fittings made out of 40 mm bore (light grade) GI pipe length not exceeding 1.5 meter long, fixed with 02 sets of flat iron clamp of size 25mm X 5 mm with bolts, nuts and washer of suitable size including applying two coats of aluminium paint ovar a coat of red oxide primers complete all as specified and directed.
Supply, laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 50 Sqmm 3.5 core complete all as specified. (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.(For main incoming supply from officer inclave substation to proposed feeder pillar)
Supply, laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 35 Sqmm 3.5 core (For building main supply from feeder pillar to building bus bar chamber) complete all as specified. (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.(For main incoming supply from officer inclave substation to proposed feeder pillar)
Supply, laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 25 sqmm 3.5 core(For ADC room and guard room) complete all as specified. (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.(For main incoming supply from officer inclave substation to proposed feeder pillar)
Supply, laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 16 sqmm 4 core(for Street light and fountain pump) complete all as specified. (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.(For main incoming supply from officer inclave substation to proposed feeder pillar)
Supply, laying and testing in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 10 sqmm 2 core (For bollard light and Gate light) complete all as specified. (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.(For main incoming supply from officer inclave substation to proposed feeder pillar)
Supply and fix steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate and finial taper plug and single swan neck, including two coats of alumunium paint over a coat of red oxide primer and pole embedded in concrete shall be painted with black bitumineous paint complete all as specified and directed .(Excavation and concrete work to be measured and paid separately)
(HOT WATER SUPPLY) Supplying, erecting, testing and commissioning of solar water headting system with heat exchanger for cold & warm regions respectively with solar flat plate collector conforming to IS : 12933 (part 1) with amdt.no.1 and IS : 12933 (part 2)/2003 suitable for inlet water with chlorine and fluorine content up to 100 ppm and supply hot water at the outlet of 100 Litters Capacity with out elctrical back up meeting specifications as under and comprising of followings :- Supply and fixing Rotational Moulded Polyethylene water Storage Tank (Cylindrical Vertical with closed lockable top with lid and locking arrangements) hoisted and fixed in position all as specified in SSR Part-I of capacity 100 Litters 100 Litters complete for storage of cold water feeding to Solar water heater, including 3 meter staging made out of MS Angle iron 50X50X6 mm all as specified and directed at site by Engineer-in-Charge -1 No. Material:1. Solar water heating system: Comprising of solar flat plate collector, collectors stand assembly, stainless steel insulated hot water storage tank with heat exchanger and various other components. Solar flat plate collector component shall have: * Solar flat plate collector cover plate made of toughened glass * Sheet for absorber made of copper * Absorber made of copper sheet and copper tube. Solar Flat Plate Collector: Solar flat plate collector shall conforming to IS: 12933 (Part 1) with amdt no.1 and IS: 12933 (Part 2)/2003 and various components shall be as under : Cover plate: Cover plate shall be toughened glass and thickness of 4.0 mm (min) conforming to section-1 of IS: 12933 (Part-2)/2003. The solar transmittance of the cover plate shall be minimum 82 percent at near normal incidence. Collector Box: Collector box shall be made of Aluminium sections only. Type, grade, size, workmanship and finish of the material used shall be as per section-2 of IS: 12933(pt2/2003). The minimum thickness of Aluminium shall be as under. (a) Channel section for sides 1.6 mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm (d) Sheet for entire body 1.0 m
Absorber: Absorber shall consist of riser, header and sheet for absorer. The Diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71mm. The Diameter of riser shall be 12.7 +/- 0.5mm and thickness 0.56 and made of copper only. The distance between the risers from centre to centre shall be 120mm. Type grade, size, workmanship and finish of the material used shall be as per section-3 of IS:12933 (Part 2)/2003. Riser and header assembly designed for working pressure up to 24.5 K Pa (2.5 kg/cm2 shall be tested for leakage at a minimum hydraulic pressure of 490 K Pa (5 kg/cm2). Sheet for absorber: Sheet for absorber shall be made of copper only. Type, grade, size, workmanship and finis of the material used shall be as per section-3 of IS: 12933 (pt2)/2003. A sample piece of he absorber for having minimum area of 400 square cm. shall be heated in an oven at temperature of 175 degree C for 2 hours. After heating, the sample shall be taken out from the oven and cooled at room temperature. The cooled sample shall be inspected visually for damages, if any. There shall not be any appearance of blistering/rupture/peeling off of the coated/painted surface and of weakening of the bonding between absorber sheet and risers/headers. Collector box insulation: Insulation shall be provided at back and sides. Thermal Resistance (R) of insulation material shall be minimum 0.96 m square degree C/W for side insulation. This shall be derived after determining thermal conductivity (K) value at 100 degree C mean temperature in accordance with IS : 3346. Collector box insulation shall conform to sec.4 of IS: 12933(Part-2)/2003 Gaskets and Grommets: Gaskets and Grommets shall conform to sec.5 of IS: 12933 (Part-2)/2003.
Insulated hot water storage tank : The thickness of the water storage tank shall be uniform. Material: Insulated hot water storage tank shall be non-pressure type and made of stainless steel grade (X04Cr19Ni9 or X07Cr18Ni9 of IS : 1570 (part 5)/1985), TIG welded. Insulation: Solar water heating system (SWHS) up to and including 100 LPD shall be insulated with 40 mm thermal grade PUF insulation of 32 kg/meter cube or higher density. PUF insulation could be pre extruded type fitted with FRP exterior cladding or alternatively injection moulded in a twin walled steel tank and PPE end cap. Other systems shall be insulated with 100 mm thick Rock wool of 48 kg/m3 density with 22swg Aluminium cladding. Systerms up to 100 LPD may also alternatively be installed with 100 mm thick Rock wool of same specifications with aluminium or Gl powder coated cladding. Tank stand: Tank stand assembly shall be made of MS angle of size (min) 38X38X4 mm duly pre-treated and stove enamelled with black colour paint. Alternatively tubular structure with Powder coating could also be provided. Heat Exchanger: Heat Exchanger shall be cage type and made of copper/stainless steel tubes of grade X04Cr19Ni9 or X07Cr18Ni9 of IS: 1570(part 5)/1985. Heat exchangers shall have a minimum of 0.24 squre meters heat transfer area per 100 LPD capacities. System inter connecting piping: ISI marked G.I pipes, medium class of IS: 1239 duly insulated with 50 mm thick rock wool of 48 kg/m3 density and 26 swg Al cladding. EPDM hose pipes can also be used for systerms up to and including 500LPD. Collector stand : Collector stand assembly shall be made of MS angle of size 38X38X4 mm duly pre-treated and stove enamelled with black Colour paint. Alternatively tubular structure with Powder coating could also be provided.
Make up water tank: The capacity of make up tank shall be up to 250 LPD. (considered separately) Temperature Gauge: Dial type, duly calibrated and suitable for temperature range from 0 degree C to 120 degree C and shall be provided. Valves: 3 valves, one for inlet, outlet and make up tank each. The Contractor shall submit schematic arrangements of all components of SWH and get it approved form Garrison Engineer. The exact location of SWH on roof top of the Building shall be decided by the Garrison Engineer. Note for hot water supply system: - For Energy conservation measures solar water heater will work as a preheater for Geysers. All geysers water supply will be fed from solar water heater oulet.
Supply, Install, Testing and Commissioning of strorage water heater/Geyser 15 liters with all standard accessories complete with 2 Nos. Inlet outlet pipes for hot and cold water as standard fitting and complying the following specification:- (i) Type :- Vertical (ii) Capacity of inner tank - 15 liters (iii) Colour :- White (iv) Temperature sensitive LED indicators (v) Feather tough digital temperature control (vi) Shock proof 3 pin plug (vii) Up to 8 bar pressure resistant inner tank (viii) Multifunctional safety valve (ix) IPX4 technology to protect electrical parts from water splash (x) Earth leakage current breaker to cut off power immediately in case of current leakage and protect user from electric shock (xi) Built in Thermostat (xii) Built in thermal cut off (xiii) Tank:- Made with ultra thick super cold rolled steel plates dry powder coating finish and energy saving hisgh density PUF insulation (xiv) Heating element - Glass coated heating element with resistant to oxidation and carbonation at high temperature of 2000W capacity. (xv) Heavy duty magnesium anode rod with steel core to protect enamelled tank from rust and corrosion (xvi) 230V, single phase, 50 Hz Ac power supply operated (xvii) 5 STAR energy saving rating with BEE Lable.
(B/R ITEM) Material & Labour for mixing of fly ash, clinker & stone dust in proportion of 1:3:6 (i.e 10% Fly ash, 30% Clinker and 60% Stone dust materials) laying, watering, ramming and compacting with vibratory roller to get min CBR value &% and Dry density 97% placed at required camber and gradient complete as directed by Engr-in-Charge.
NIRMAL SALES CORPORATION
Prasur Electricals & Engineering Co.
UNITED BUILDERS
M/s Bhola Shah Bansi Lall
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .