Loading…
Loading…
Tender Value
₹3.0 Cr
EMD Value
₹3.0 L
Closing Date
26 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
NORTH
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N OR 'V' Whichever is less; where. V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per ANNEXURE-XXXIII, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Trenching, cable laying, location and signal foundation/ erection/ termination/ wiring in connection with any signalling work. OR Any Indoor or combined indoor/ outdoor signalling work including supply, installation, testing and commissioning of relay interlocking (RRI/PI) system for passenger carrying lines.
8 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender document, Scope of work & GCC 2022 are attached with the tender.
Signalling work in connection with closure of LC gates 21,22,23,25,26 and 27 by provision of ROB in Kalyan- Lonavala section of Mumbai Division.
CR-BB-SNT-NORTH-2026-16
CR-BB-SNT-NORTH-2026-16
Open
Works - General
18 Months
Mumbai, Maharashtra
₹0
₹3.0 L
26 Mar 2026
26 Feb 2026
12 Mar 2026
154 items across 3 schedules · ₹2,51,76,442.7 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of Indoor Jumper wire ATC 1x1 mm dia. Conforming to IRS/76/89 (Amd.3) of latest.(Inspection Agency-Consignee) | Numbers | 2.00 | 11,585 | 23,170 |
| 2 | Supply of PVC Indoor Cable 1 x 24 x 1 mm dia Colour coding of insulation of inner conductor shall be in eight colour viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency-Consignee) | Kilometre | 2.00 | 2,46,408 | 4,92,816 |
| 3 | Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amd.3) or latest.(Inspection Agency- Consignee) | Kilometre | 2.00 | 7,770 | 15,540 |
| 4 | Supply of PVC flexible copper cable single core multistrand 1 x 10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as p e r IS 694/2010 with latest amendment if any.with insulation thickness of 1.0mm nominal conductor resistance 1.91 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Inspection Agency-Consignee) | Kilometre | 2.00 | 1,19,222 | 2,38,444 |
| 5 | Supply of PVC flexible copper cable single core multistrand 1 x 25 Sq.mm (196 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS:694/2010 with latest amendment if any with insulation thickness of 1.2mm nominal conductor resistance 0.780 ohms/Km and test parameters are as per IRS (S)76/89 (Amd.3).(Inspection Agency- Consignee) | Kilometre | 2.00 | 2,79,653 | 5,59,306 |
| 6 | Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender.(Inspection Agency-Consignee) | Kilometre | 2.00 | 5,605 | 11,210 |
| 7 | Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure attached in tender document and Rack arrangement as per Sketch no SK- 727 and Rack plan as approved by Engineer in charge.(Inspection Agency-Consignee) | Set | 2.00 | 30,325 | 60,650 |
| 8 | Supply of Tag Blocks 200/160/120 way with polycarbonate cover as per IRS S 77- 2006(Rev.1) RDSO DRG. No. SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in- charge.(Inspection Agency-Consignee) | Numbers | 18.00 | 1,217 | 21,906 |
| 9 | Supply of 8-Way Terminal strips, made of PBT, isolating barrier type as per IRS-S-79/92 (Amd.2) & Drg No SA24811 (Alt.2) & SA24812 (Alt.2) with latest amendement. (Inspection Agency-Consignee) | Numbers | 180.00 | 364 | 65,520 |
| 10 | Modification in existing EI system as per latest TAN, it includes :- Design and modification in existing interface and interlocking circuit of EI system, including modification in VDU,CCIP,MT,Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signalling plan/diagrams. Required hardware will be provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires, fuses etc.). The work includes supply of modified ST/LT, interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All Plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies(6 sets). Alteration involving modification in upto 10 routes(Inspection Agency-Consignee) | Per Alteration | 1.00 | 14,63,145 | 14,63,145 |
| 11 | Supply of QL1 LATCH relay, 11F-4B or 8F-6B along with plug board, retaining clip and connectors conforming to BRB:935A. (Inspection Agency-RDSO) | Numbers | 6.00 | 4,006 | 24,036 |
| 12 | Supply of Tag Blocks 96/100 way with polycarbonate cover as per IRS S 77- 2006(Rev.1) Requirement of each type shall be specified by Engineer-in-charge. (Inspection Agency-Consignee) | Numbers | 30.00 | 1,391 | 41,730 |
| 13 | Supply of Resisters, condensers, Diodes, LEDs and lugs alongwith bracket and mounting arrangement as per standard Annexure-xx of Central Railway.(Inspection Agency-Consignee) | Lot | 3.00 | 46,725 | 1,40,175 |
| 14 | Lacing thread rolls, black, wax coated (100 mtrs).(Inspection Agency-Consignee) | Numbers | 60.00 | 57 | 3,420 |
| 15 | Supply of QNNA1- AC immunised relay, 4F- 4B,24VDC along with plug board, retaining clip and connectors conforming to BRS:960, IRS:S60, IRS:S34 & IRS:S23. (Inspection Agency-RDSO) | Numbers | 3.00 | 4,129 | 12,387 |
| 16 | Supply of Modular terminal block of 2.5 sq.mm 2 in 2 out type disconnect type terminal along with as per RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection Agency-Consignee) | Numbers | 3000.00 | 100 | 3,00,000 |
| 17 | Supply of DIN Channel for the terminals 1 Mtrs each.(Inspection Agency-Consignee) | Numbers | 60.00 | 187 | 11,220 |
| 18 | Supply of End plates for modular terminal block.(Inspection Agency-Consignee) | Numbers | 150.00 | 20 | 3,000 |
| 19 | Supply of End Clamp for modular terminal block.(Inspection Agency-Consignee) | Numbers | 180.00 | 15 | 2,700 |
| 20 | Supply of Marker Card as per customer spec. (10x10)(Inspection Agency-Consignee) | Numbers | 30.00 | 71 | 2,130 |
| 21 | Fuse terminal block with LED indication upto 2.5 sq.mm screw type one in one out (suitable for (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) as per RDSO/SPN/189/2004. (without fuse)(Inspection Agency-Consignee) | Numbers | 300.00 | 157 | 47,100 |
| 22 | End plate for through terminal block with LED indication.(Inspection Agency- Consignee) | Numbers | 90.00 | 12 | 1,080 |
| 23 | Fuse links of (400 mA, 630mA, 1A. 1.6A, 2A, 4A, 6.3A & 10A) (Inspection Agency- Consignee) | Numbers | 600.00 | 37 | 22,200 |
| 24 | Shorting link insulated Grey in colour. (Inspection Agency-Consignee) | Numbers | 300.00 | 13 | 3,900 |
| 25 | Operating tool (operating tool, screw driver & stripper) as per Annexure-xix.(Inspection Agency-Consignee) | Numbers | 1.00 | 7,266 | 7,266 |
| 26 | Supply of Main Signal Post 140 mm outer dia 4.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee) | Numbers | 3.00 | 5,979 | 17,937 |
| 27 | Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments.(Inspection Agency- Consignee) | Numbers | 3.00 | 8,119 | 24,357 |
| 28 | Supply of Cast Iron Main signal surface base 140mm as per spec No IRS S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg. No. SA-23156(Adv), SA-23153 (Adv) & SA-23150 (Adv) Alt. 1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C. Rly practice(Inspection Agency-Consignee) | Numbers | 6.00 | 7,944 | 47,664 |
| 29 | Supply of Hand Cuff Locks/ Godrej Navtal lock with Three common keys.(Inspection Agency-Consignee) | Numbers | 60.00 | 245 | 14,700 |
| 30 | Supply of Key Lock Relay with different ward combinations (Three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24V DC or functional equivalent without base plates. RDSO/SPN/219/ 2016 Version 1.0 d 1(Inspection Agency-Consignee) | Numbers | 6.00 | 7,948 | 47,688 |
| 31 | Supply of "4 Aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post Saves pigment finish on the back side of the end inside. White Pigment finish inside the 4 aspect unit to avoid any extra paint cost.(Inspection Agency-Consignee) | Numbers | 6.00 | 34,638 | 2,07,828 |
| 32 | Supply of Program switches, snap action, base mounting type along with cover and mounting bracket 63A-7 pole 3 position Siemens type (3 LAO-63/7Y) / L&T/HAVELLS type. Drg. No. RST.C.106(Inspection Agency- Consignee) | Numbers | 6.00 | 6,595 | 39,570 |
| 33 | Supply of Transformer 230V/110V-130V Single Phase 2 KVA as per spec. IRS S-72/88 (Amd.2) with latest amendments.(Inspection Agency-Consignee) | Numbers | 1.00 | 8,945 | 8,945 |
| 34 | Supply of Track Feed Transformer 230V/110V-130V Single Phase 3 KVA single phase as per spec. IRS S-72/88 (Amd.2) with latest amendments.(Inspection Agency- Consignee) | Numbers | 5.00 | 10,531 | 52,655 |
| 35 | Supply of Battery Charger self regulating floor mounting type with 230 V AC single phase input and output 60 V DC, 40A as per spec. IRS.S.86/2000(Amd.4) with latest amendments. for Axle counter applications (Amd.4).(Inspection Agency-Consignee) | Numbers | 5.00 | 1,07,550 | 5,37,750 |
| 36 | Supply of Rubber Mat 5mm thick for use in signalling installation.(Inspection Agency- Consignee) | Kg | 300.00 | 112 | 33,600 |
| 37 | Supply of Signal Group, 3 Aspect without base plate Siemens make [No. A-RT-RG- A067] or functional equivalent and should be suitable for working with LED based signal lighting unit.(Inspection Agency-RDSO) | Numbers | 5.00 | 49,131 | 2,45,655 |
| 38 | Supply of Signal Group, 4 Aspect Siemens make (No. A-RT-RG-A057) or functional equivalent without base plates.(Inspection Agency-RDSO) | Numbers | 2.00 | 49,312 | 98,624 |
| 39 | Supply of Route Group Siemens Make ( No.RSSK 31/0002) or functional equivalent without base plates.(Inspection Agency- RDSO) | Numbers | 4.00 | 51,869 | 2,07,476 |
| 40 | Supply of Auto Signal Block Proving Relay Group Siemens make [No. A-RT-RG-A056] or functional equivalent without base plates. (Inspection Agency-RDSO) | Numbers | 6.00 | 43,430 | 2,60,580 |
| 41 | Supply of Desk type Electronic Magneto Telephone as per spec No IRS TC-79/2000 (Amd.4) or with latest amendments. (Inspection Agency-Consignee) | Numbers | 6.00 | 2,501 | 15,006 |
| 42 | Supply of Signal No.plates. as per Drg No RST-11393 / SK-842 or latest(Inspection Agency-Consignee) | Numbers | 60.00 | 447 | 26,820 |
| 43 | Supply of A/AG/C/P/G/IB Board as per Drg. RST-11444/1(A), RDSO Drg No SA 23460(AG), SA-23461( C), RST-11445. SA 23456(P), SA 23477(G) & SA 23476-77(IB) as applicable respectively with Latest Amendment.(Inspection Agency-Consignee) | Numbers | 30.00 | 476 | 14,280 |
| 44 | Supply of Stop Board/IB Board as per RST- 11791 (STOP BOARD)/ RDSO Drg No.7235/B as per extent C.Rly practice.(Inspection Agency-Consignee) | Numbers | 12.00 | 2,763 | 33,156 |
| 45 | Supply of different warning Boards as per Goods Warning Board (SK-784). RDSO Drg No. SA 2380 (Adv), SA 2370/M, Block section limit Board RDSO Drg.No. SA 2373 Paint and retroreflective arrangement as per Railways drawing.(Inspection Agency-Consignee) | Numbers | 18.00 | 2,795 | 50,310 |
| 46 | Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extant practice & as per instruction of Rly engineer at site. DRG.No.SK-844.(Inspection Agency- Consignee) | Numbers | 6.00 | 4,381 | 26,286 |
| 47 | Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995.(Inspection Agency- Consignee) | Numbers | 6.00 | 4,649 | 27,894 |
| 48 | Supply of FIBRE GLASS INSULATING FIRE RETARDENT SHEET OF 10 MM THICKNESS AS PER ISO:10192-1982, Dielectric strength- 25KV/mm with glass content 25 to 34% in standard size of 1.10x1.10 Mtr. as per Spec. No. IS:10192-1982.(Inspection Agency- Consignee) | Numbers | 6.00 | 5,065 | 30,390 |
| 49 | Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA- 23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection Agency-Consignee) | Numbers | 2400.00 | 65 | 1,56,000 |
| 50 | Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses.(Inspection Agency-Consignee) | Numbers | 180.00 | 144 | 25,920 |
| 51 | Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity(Inspection Agency- Consignee) | Numbers | 90.00 | 62 | 5,580 |
| 52 | Supply of earth electrode assembly as per Drg.No. CR/S&T/SK-815(Inspection Agency- Consignee) | Numbers | 19.00 | 951 | 18,069 |
| 53 | Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No. IRS: S 17-75 Revision 3.(Inspection Agency-Consignee) | Numbers | 1200.00 | 2 | 2,400 |
| 54 | Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13@45>46@(Inspection Agency-Consignee) | Kg | 120.00 | 75 | 9,000 |
| 55 | Supply of Bond Plates suitable for terminating track lead connections of AFTC on rail. It consists of tapered stainless steel bolts, nuts, check nuts, washers, L-shaped plate etc., as per Drg.No.RST 11630. Each set of bond plates should consist of (i) SS Taper pins - 8 nos. (ii) SS M6 nuts - 20 nos. (iii) SS M6 plane washers - 32 nos. (iv) Spring washer - 8 nos. (v) Nylon nuts - 8 nos. (vi) S.S.hex bolts M6x15 - 2 nos. (vii) Track circuit cable plates - 4 nos. Supply of all above items would costitute one set. (Inspection Agency-Consignee) | Set | 12.00 | 2,700 | 32,400 |
| 56 | Supply of Pre-wired Crank Handle cum key lock relay box (of metal) alongwith LEDs, with approved type push buttons, 8-way terminal strips, string rod, etc. as per Drawing No.RST.C.114(Inspection Agency- Consignee) | Numbers | 2.00 | 8,891 | 17,782 |
| 57 | Supply of GI pipe, inner dia. 100mm dia. B- class as per spec. No.IS 1239 PT. 1/2004 or l a t e s t with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make.(Inspection Agency-Consignee) | Metre | 180.00 | 908 | 1,63,440 |
| 58 | Sealed maintenance free VRLA Battery/Cell 2 Volt, 300AH IRS : S-93/96 (A) (Amd.1) or latest.(Inspection Agency-Consignee) | Numbers | 120.00 | 3,755 | 4,50,600 |
| 59 | Sealed maintenance free VRLA Battery/Cell 2 Volt, 200AH RDSO SPN/93/96 (A) (Amd.1) or latest.(Inspection Agency-Consignee) | Numbers | 240.00 | 2,611 | 6,26,640 |
| 60 | Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest.(Inspection Agency- Consignee) | Metre | 180.00 | 288 | 51,840 |
| 61 | Supply of RCC pipes 150mm dia alongwith collars as per IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) | Metre | 30.00 | 516 | 15,480 |
| 62 | Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) | Numbers | 440.00 | 189 | 83,160 |
| 63 | Supply of RCC pipes half round of size 300mm dia outer and 250 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection Agency-Consignee) | Numbers | 30.00 | 365 | 10,950 |
| 64 | Supply of Thermo shrink Cable Jointing kit (Reinforced) TSF-2 type generally conforming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.CR/SPN/TC/57(A)/2015 Dt. 06.01.2015(Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables along with sub-kit (Table-B) for armour continuity.(Inspection Agency- Consignee) | Numbers | 6.00 | 2,710 | 16,260 |
| 65 | Supply of 4.5 kg CPO2 type fire extinguisher along with all accesories, extinguisher testing certificate has to be supplied along with - Supply of ISI marked Carbon Dioxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc. as required by site Engineer.(Inspection Agency-Consignee) | Numbers | 12.00 | 4,321 | 51,852 |
| 66 | Design, fabrication and supply of Fuse Auto Changeover System for 32 Nos. of external non-deteriorating type fuses or 'G' type fuses from 0.6 Amp to 4 Amp capacities used in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any.(Inspection Agency- Consignee) (UNIT NUMBER SHOULD BE READ AS NO OF MODULES) | Numbers | 12.00 | 23,147 | 2,77,764 |
| 67 | Design, fabrication and supply of Fuse Auto Changeover System for 24 Nos. of external non-deteriorating type or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operaton circuits. System shall have 6 cards with monitoring of 4 fuses in one card. As per RDSO Spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection Agency-Consignee) (UNIT NUMBER SHOULD BE READ AS NO OF MODULES) | Numbers | 12.00 | 33,712 | 4,04,544 |
| 68 | Supply of Paints as per relevant IS specification preferably Asian/ Apcolite/Dulux m a k e in different colours in 1 Kg/2 Kg pack(Inspection Agency-Consignee) | Kg | 120.00 | 306 | 36,720 |
| 69 | Supply of QNA1-K AC immunised relay, 8F- 8B, 24VDC along with plug board, retaining clip and connectors conforming to BRS:931A & RDSO letter no.STs/E/Relays/ UEA/PI dated 30.05.97 Annexure-II IRS:S60, IRS:S34 & IRS:S23. (Inspection Agency-RDSO) | Numbers | 6.00 | 3,540 | 21,240 |
| 70 | Supply of QNN1 Twin neutral line relays, 24 VDC 4F-4B/5F-3B/6F-2B contacts. complete with plug board, retaining clip and connectors BRS : 960.(Inspection Agency- RDSO) | Numbers | 6.00 | 5,322 | 31,932 |
| 71 | Supply of QSPA1 relay, 24VDC, slow to pick up, 8F-4B, along with plug board, retaining clip and connectors conforming to BRS:933A, IRS : S60, IRS:S34 & IRS:S23(Inspection Agency-RDSO) | Numbers | 6.00 | 3,678 | 22,068 |
| 72 | Supply of Universal LED Lamp proving relay QECX61 relay, 4F-4B,AC conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 (FOR ALL ASPECT ECR FOR AC LED SIGNAL)(Inspection Agency- RDSO) | Numbers | 12.00 | 3,317 | 39,804 |
| Schedule total | ₹82,14,667 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC 2022
ATTACHMENT
CORRECTIONSLIP1to10GCC2022.pdf GCC CORRECTION SLIP 1 TO 10
ATTACHMENT
FINALNEWTENDERDOC2026-16.pdf TENDER DOC
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY.pdf
ATTACHMENT
CORRECTIONSLIP1to10GCC2022.pdf
ATTACHMENT
FINALNEWTENDERDOC2026-16.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .