Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹13.3 L+₹6.8 L (104.5%)Rejected-Finance | L2 | Rejected-Finance Awarded being 2nd Lowest Bidder |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
30 Aug 2022, 6:00 pmClosed
Shri Niranjan Lal EE GE(S) Bathinda
GE(S)BATHINDA BATHINDA MI STN
GE(S) BTD TOKEN NO 28 OF 2022-23 CLEANING OF SEWAGE LINES MAN HOLES AND REPAIR REPLACEMENT OF SEWAGE LINES MANHOLES MANHOLES COVER IN SECTOR II III AND IV IN AGE BR II UNDER GE(S) BATHINDA AT BATHINDA MILITARY STATION(2ND CALL)
2022_MES_536681_2
GE(S)/BTD/TOKEN NO 28/2022-23
Open Tender
Civil Works
Item Rate
330 days
GE(S)BATHINDA
Class E
Category a(ii)
11 documents required · 11 mandatory
₹500
GE(S)BATHINDA
₹20,000
Yes
22 Oct 2022
8 Aug 2022
1 Sept 2022
8 Aug 2022
30 Aug 2022
16 Aug 2022
Amount
Material and labour for Cleaning/removal of blockage from bathroom, kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto first manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed .
Material and labour for Cleaning/removal of blockage from EWC/IWC (any type) including connected traps (any type), pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users, including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed .
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole not exceeding 15mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/colony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed .
Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole exceeding 15 mtr but not exceeding 30 mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200 metres from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified and as directed .
Note for item No 01 to 04
Contractor must employ Minimum ten nos labourer's daily i.e. 04 Nos for Karam Singh & Bana singh Enclave, 03 Nos for Sanjay Singh & Albert Ekka Enclave ,03 for OTM Accn Area complete all as specified and as directed .
Contractor or his representative shall report daily at 09.00 AM except on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge.
In case of non attaedence of complaints against BOQ item 01 and 02 above by the contractor on the same day, a penalty of Rs 200/- per complaint per day and for complaints against BOQ item 03 to 05 above, a penalty of Rs 100/- per complaint per day will be recovered from the contractor due complete all as specified and as directed .
The cost for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc and all other other materials for execution of the work shall be included in the unit rate complete all as specified and as directed .
A complaint register shall be maintained by JE and proper record of complaints received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engineer-in-Charge after completion of work complete all as specified and as directed .
De- sludging from existing manholes, septic tanks and soakage wells of any capacity, size and depth including disposal of sludge etc and taking off the manhole cover and placing in the same position after taking out sludge through mechnically sewage suction pump and dividely store in covered container etc complete and removing the sludge in covered van/trolly outside the MD land all as specified and directed . Nate :- Dewatering of existing manhole/septic tank will not be measured only solid material will be measured complete all as specified and as directed .
De-watering of existing soak wells of any capacity size and depth including taking off the manhole cover and placing in the same position after taking out waste sludge water through machanically sewage suction pump/honey sucker machine and divdely store in covered container etc complete and removing the waste sludge water in covered van/trolly outside the MD land complete all as specified and as directed .
Dismantling the SGSW pipe 100 mm dia for removal of blockage and replace only dismantling SGSW pipe and jointing with cement all around with PCC 1:2:4 including required T&P etc complete all as sepcified and as directed . (Note: Earth work shall be measured and paid seperately)
Dismantling the SGSW pipe 200mm dia for removal of blockage and replace only dismantling SGSW pipe and jointing with cement all around with PCC 1:2:4 including required T&P etc complete all as sepcified and as directed . (Note: Earth work shall be measured and paid seperately)
Dismantling the SGSW/Hume pipe 300 mm dia for removal of blockage and replace only dismantling SGSW/Hume pipe and jointing with cement all around with PCC 1:2:4 including required T&P etc complete all as sepcified and as directed . (Note: Earth work shall be measured and paid seperately)
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m deep for foundation, etc. or for shafts, wells, cesspits, manholes, etc. not exc 10 Sqm on plan and not exc 1.5 m depth & getting cut in soft/loose soil complete all as specified and as directed .
All as per item No 16 (Here-in-before) but exc 1.5 m but n.exc 3.00 m depth complete all as specified and as directed .
Returning filling in including spreading, levelling, watering & well ramming in layers not exceeding 25cm thick complete all as specified and as directed .
Removal of excavated material to a distance not. exceeding 50m & depositing where directed at level not exceeding 1.5m above the starting point complete all as specified and as directed .
Demolition and breaking up drain 200mm in internal dia pipes (SGSW, AC or Re-inforced concrete) of any dia set in cement laid in trenches incl all fittings & accessories complete all as specified and as directed .
Demolition and breaking up drain 150mm in internal dia pipes (SGSW, AC or Re-inforced concrete) of any dia set in cement laid in trenches incl all fittings & accessories complete all as specified and as directed .
Demolition and breaking up drain 75mm in internal dia pipes (SGSW, AC or Re-inforced concrete) of any dia set in cement laid in trenches incl all fittings & accessories complete all as specified and as directed .
M & L for 200 mm dia (internal) SGSW pipes, grade 'A' laid in trenches & jointed complete all as specified and as directed .
M & L for PCC 1:3:6 type C-2 conc bed using 40mm graded stone agg to drain pipe including packing under & haunching against the sides of pipe 200 mm dia ( internal) after these are laid in trenches complete all as specified and as directed .
M & L for 150mm dia (internal) SGSW pipes, grade 'A' laid in trenches & jointed complete all as specified and as directed .
M & L for PCC 1:3:6 type C-2 conc bed using 40mm graded stone agg to drain pipe including packing under & haunching against the sides of pipe 150 mm dia ( internal) after these are laid in trenches complete all as specified and as directed .
M & L for 100mm dia (internal) SGSW pipes, grade 'A' laid in trenches & jointed complete all as specified and as directed .
M & L for PCC 1:3:6 type C-2 conc bed using 40mm graded stone agg to drain pipe including packing under & haunching against the sides of pipe 100 mm dia ( internal) after these are laid in trenches complete all as specified.
Dismantling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed .
S&F 100mm dia Cast Iron, spun pipe, soil waste & vent pipes in any length with or without ears, with cement joints but fixed to walls & fixing with clamps complete all as specified and as directed .
Descreption all as per Srl item No. 28 but fixing only old pipes complete all as specified and as directed .
Descreption all as per Srl item No. 28 but laid in Tranches complete all as specified and as directed .
Dismantling and disconnecting of existing CI soil vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed .
S&F 75mm dia Cast Iron, spun pipe, soil waste & vent pipes in any length with or without ears, with cement joints but fixed to walls & fixing with clamps complete all as specified and as directed .
Descreption all as per Srl item No. 32 but fixing only old pipes complete all as specified and as directed .
Descreption all as per Srl item No. 32 but laid in Tranches complete all as specified and as directed .
S&F 100mm bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door, complete all as specified and as directed .
S&F 75mm bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door, complete all as specified and as directed .
M&L in repair for 100mm dia of CI floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed .
M&L in repair for 75mm dia of CI floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed .
S & F in repairs cast iron oval access door of size 75mm size etccomplete all as specified and as directed .
S & F in repairs cast iron oval access door of size 100mm size etccomplete all as specified and as directed .
Cutting in to existing manhaoles for connecting new drains, making good to pipe and rendering, cutting out existing benching for as specified dia of pipe 150mm complete all as specified and as directed .
Demolition of cement concrete (re-inforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed .
M & L for precast cement concrete type B1 1:2:4 (20 mm graged aggregate) as in manholes covers, Kitchen sink slab, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in cement mortor(1:4) complete with joints to match complete all as specified and as directed .
M&L for RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) for slabs supported on walls, shelves, beams and columns, lintels, fins, facia and Chajjas etc and the like, including form work complete all as specified and as directed .
M&L for TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed .
Demolition of brick work built in cement mortor in any condition complete all as specified and as directed .
M&L brick work with sub class `B' bricks straight or curved on plan exc 6.0m mean radius built in cement mortor 1:4 complete all as specified and as directed .
Descreption all as per Srl item No. 47 but except bricks complete all as specified and as directed .
M&L PCC 1:4:8 type D-2 using 40mm graded crushed stone agg for foundations, filling & mass concrete in manholes etc complete all as specified and as directed .
M&L PCC 1:2:4 type B-1 using graded stone aggregate at manhole bedding & coping complete all as specified and as directed .
M & L for rendering 15mm thick on brick work or concrete surfaces in CM (1:4) with water proofing compound (WPC to be measured & paid seperately) and finished the surface even & smooth with using extra cement etc complete all as specified and as directed . (internal surfaces)
M&L 15mm thick cement plastering in CM 1:4 on other than fair faces of brick work or concrete surfaces finished even & smooth without using extra cement. (external surface) complete all as specified and as directed .
Supply only water proofing compound ISI marked etc complete all as specified and as directed . Make:- Dr. Fixit as per manufacturer's instructions and specification
S & F in repairs vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440 X 260 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl lime concrete bedding and connection to anti syphonage pipe etc including making good to floor complete all as specified and as directed .
Providing and fixing SFRC (Steel Fibre Reinforced Concrete) Cover and frame (heavy duty HD-20 grade designation) 650 mm internal diameter/ clear opening 70cm x 70cm conforming to I.S. 12592, total weight of cover and frame to be not less than 182 Kg., fixed in cement concrete (1:2:4) etc complete all as specified and directed .
S&F SFRC (Steel fibre Reinforcement concrete cover & frame )heavy duty HD-20mm graded designation 560mm internal dia conforming to IS 12592, total weight of cover & frame to be not less than 182 Kg fixed in cement concrete 1:2:4 etc complete all as specified & directed.
S&F SFRC (Steel fibre Reinforcement concrete cover & frame) HD-20mm graded rectangular.Internal Size 590X590mm & External size of frame 800X800X100mm including Manhole cover havinng size 590X590X50mm thick and fixed over earthing manhole after demolition of PCC coping & manhole Cover & set in CM 1:4 including PCC benching in CM (1:2:4) and finishing smooth complete all as specified and as directed .
Note:- Net contract sum shall be calculated after deduction of Sch of credit.
ABHINANDAN ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .