Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹22.8 L | L1 | Accepted-AOC Accepted being lowest bidder |
| 2 | L2₹24.1 LRejected-Finance BIR SARDALIA RESIDENCY AIR FORCE ROAD BARYAL UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹24.1 L | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹24.4 LRejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹24.4 L | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹27.4 LRejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹27.4 L | L4 | Rejected-Finance Not lowest bidder |
| 5 | L5₹30.2 LRejected-Finance | ₹30.2 L | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | K S BUILDERS L3 | M/SHansrajbuilder L1 | SARDALIA CONST CO L2 | M/S SUKRALA ELECTRICAL WORKS L5 | DAVINDER SINGH L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 250 | Cum | 126 ₹31,500 | 90 ₹22,500 | 200 ₹50,000 | 72 ₹18,000 Lowest | 90 ₹22,500 |
| 2.00 | Excavation in trenches n.exc 1.5 mtr wide and exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 0.25 | Cum | 136 ₹34 | 90 ₹22.5 Lowest | 200 ₹50 | 1,353 ₹338.25 | 90 ₹22.5 Lowest |
| 3.00 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been errected and tested, complete all as specified and as directed. | 163 | Cum | 16 ₹2,608 | 5 ₹815 Lowest | 20 ₹3,260 | 73 ₹11,899 | 25 ₹4,075 |
| 4.00 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. | 87 | Cum | 16 ₹1,392 | 5 ₹435 Lowest | 20 ₹1,740 | 73 ₹6,351 | 25 ₹2,175 |
| 5.00 | M & L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm width with equal to length complete all as specified and as directed. | 74 | Per 1000 No's | 2,606 ₹1,92,844 | 3,000 ₹2,22,000 | 8,000 ₹5,92,000 | 722 ₹53,428 Lowest | 3,250 ₹2,40,500 |
| 6.00 | Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and as directed.
Note: for payment purpose punned thickness shall be measured | 74 | Cum | 186 ₹13,764 Lowest | 300 ₹22,200 | 400 ₹29,600 | 632 ₹46,768 | 300 ₹22,200 |
| 7.00 | Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 110 mm outer dia and 95 mm inner dia including taking out old unserviceable complete all as specified and as directed. | 18 | Rm | 126 ₹2,268 | 190 ₹3,420 | 690 ₹12,420 | 131 ₹2,358 | 90 ₹1,620 Lowest |
| 8.00 | Ditto- all as per item 07 but of size 160mm outer dia and 136 mm inner dia complete all as specified and as directed. | 18 | Rm | 136 ₹2,448 | 260 ₹4,680 | 690 ₹12,420 | 131 ₹2,358 | 120 ₹2,160 Lowest |
| 9.00 | Ditto- all as per item 07 but of size 200mm outer dia and 175mm inner dia complete all as specified and as directed. | 18 | Rm | 156 ₹2,808 Lowest | 300 ₹5,400 | 690 ₹12,420 | 266 ₹4,788 | 200 ₹3,600 |
| 10.00 | Taking out existing worn out/old XLPE under ground cable in 3.5 core of 185sqmm to 400sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete all as specified and as directed. | 325 | Rm | 16 ₹5,200 | 5 ₹1,625 Lowest | 30 ₹9,750 | 18 ₹5,850 | 10 ₹3,250 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
22 Jul 2026, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
REPAIR MAINT OF LT DISTRIBUTION NETWORK AND CONNECTED WORKS UNDER GE ARMY DHAR ROAD
2026_MES_774520_1
8072/NIT-35/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹64,000
Yes
21 Aug 2026
24 Jun 2026
24 Jul 2026
25 Jun 2026
22 Jul 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 250 | Cum | - | - |
| 2 | Excavation in trenches n.exc 1.5 mtr wide and exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes pier holes etc not exc 10 sqm on plan and exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. | 0.25 | Cum | - | - |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been errected and tested, complete all as specified and as directed. | 163 | Cum | - | - |
| 4 | Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. | 87 | Cum | - | - |
| 5 | M & L for Brick protection for LT cable with sub class "B" bricks laid dry and flat abutting each other with gaps between adjacent bricks not exceeding 10mm width with equal to length complete all as specified and as directed. | 74 | Per 1000 No's | - | - |
| 6 | Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and as directed.
Note: for payment purpose punned thickness shall be measured | 74 | Cum | - | - |
| 7 | Supply and laying double wall corrugated pipe (DWC) confirming to IS 14930 Part-I of size 110 mm outer dia and 95 mm inner dia including taking out old unserviceable complete all as specified and as directed. | 18 | Rm | - | - |
| 8 | Ditto- all as per item 07 but of size 160mm outer dia and 136 mm inner dia complete all as specified and as directed. | 18 | Rm | - | - |
| 9 | Ditto- all as per item 07 but of size 200mm outer dia and 175mm inner dia complete all as specified and as directed. | 18 | Rm | - | - |
| 10 | Taking out existing worn out/old XLPE under ground cable in 3.5 core of 185sqmm to 400sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete all as specified and as directed. | 325 | Rm | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tender35.pdf
Tender Documents • 2.15 MB
BOQ_867292.xls
BOQ • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].