Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC BID OF M/S AMRIK SINGH BAHRA IS HEREBY ACCEPTED BEING L1 BIDDER. | |
| 2 | L2₹43.9 L+₹5.9 L (15.6%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 BIDDER |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
10 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHILLONG
GE SHILLONG SHILLONG DIVISION PIN 793002
SPL REPAIR TO BLDG NO P 329 (SINGLE OR LIVING OR ACCN) OF 58 GTC AND PROVN OF THREE CULVERT AT THE FWG PLACES AT HAPPY VALLEY SHILLONG (A) NEAR DAH AUDITORIUM (B) NEAR ARC MANDIR LIBRARY AT ARC AND PROVN OF RETAINING WALL BEHIND BLDG NO MT 34 AT ARC
2023_MES_585114_1
GE/SHL/TOKEN-86 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE SHILLONG
₹86,000
Yes
30 Jun 2023
9 Mar 2023
11 Apr 2023
10 Mar 2023
10 Apr 2023
16 Mar 2023
Amount
AGE B/R SCHEDULE PART - I Demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 ( 12.50 mm graded aggregate) as in levelling course of tile flooring etc. complete all as specified and as directed.
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L Glazed ceramic colour tiles of size 300 x 200 x 7 mm thick (premium/special quality) in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete. Note:- Reinforcement steel will be measured & paid sepratly.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection/path/ foundation filling incl finishing even & smooth with using extra cement in, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 20mm graded aggregate) as in surface channels and drains complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etccomplete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm (ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
Demolition of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc all as specified and directed.
M & for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation complete all as specified and as directed.
M& L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 20 mm thick screed bed in CM 1:3 complete all as specified and as directed.
M& L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with 10 mm thick baking course in CM 1:4 complete all as specified and as directed.
M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces and finishing even & smooth without using extra cement including taking down cement plaster on brick or concrete wall etc including racking out joints hocking for key scrubbing down with water complete all as specified and as directed. etc.
M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm thick in CM 1:4 using finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction including taking down cement plaster on brick or concrete wall etc including racking out joints hocking for key scrubbing down with water etc. complete all as specified and as directed on External surface. Note:- WPC will be measured & Paid separately
M & L for rendering 05 mm thick in CM 1:3 on ceiling surfaces of cement concrete and finished the surface even and smooth without using extra cement including taking down cement plaster on brick or concrete wall etc including racking out joints hocking for key scrubbing down with water etc complete all as specified and as directed..
M&L for plan cement concrete 1:5:10 type E2 using 40 mm graded stone aggregate, as in foundations/sunken,filling and mass concrete complete all as specified and as directed.
M&L for water proofing treatment to sunken portion of RCC slab with the following courses of treatment/specification :- (i) For Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in sunken portion with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (ii) Preparation of plastered roof surface and applying one coat of cold bituminous primer @ 0.25 ltr /Sqm conforming to IS:3384-1986. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied by torch application over bituminous primer as specified. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. Note:-The work of sunken portion treatment shall be got executed through expert team of manufacturers or authorised applicator of manufacturer. Contractor shall submit documentary evidence on support of applicator engaged for approval of GE.
Demolition of Precast cement concrete block walling in any position, complete all as specified and directed.
M&L Precast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) complete all as specified and directed.
M & L for Providing precast cement concrete type C1, 1:3:6 (using 20mm graded stone aggregate) solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed setting in mortar 1:4 , complete, in walls complete all as specified and as directed.
Supply only water proofing compounD complete all as specified and as directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame n.exc 1.50 sqm & removing from site complete all as specified and as directed.
Taking down shutter of any description n.exc 1 Sqm each complete all as specified and directed complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm but not exc 2.00 sqm each complete all as specified and directed.
S&F for 2nd class hard wood for door chowkat,plain ,solid,straight,wrought,framed rebatedon the solid,rounded or chamfered,put together with glue pinned at joints etc complete all as specified and as directed.
Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified.
Supply and Fix Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Supply and Fix Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
M&L for resecruring or easing & adjusting without taking down shutter of any description 1 Sqm and n exc 2 Sqm each complete all as specified and as directed.
S&F 150mm size aluminium handles, cast type, anodised complete all as specified.
S&F 150mm size aluminium anodised barrel tower bolts, extruded section complete all as specified.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type B-21 complete all as specified
Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete
M&L for preparing of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Hacking out old broken glass (any thickness size quality or description) from Steel/ wooden pane glazed with putty or fixed with wooden bends complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality & glazing with oil putty or fitted with beads in squares n.exc. 0.50 sqm in each pane complete all as specified and directed.
S&F 3mm thick one side frosted glass glazing with oil putty in sq n.exc 0.5 sqm in each pane complete as specified and directed.
S&F in repairs GI wire mesh of 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified and as directed.
M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete all as specified and as directed.
Taking down GI tubing 20mm dia and connection including removable to store complete all as specified and directed.
Taking down GI tubing 15mm dia and connection including removable to store complete all as specified and directed.
S&F GI tubing 15mm dia medium grade with all fittings complete all as specified and directed.
S&F GI tubing 20mm dia medium grade with all fittings complete all as specified and directed.
Refixing old 15mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.
Refixing old 20mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.
S&F PVC water storage tanks, 500 lit capacity,rotational moulded polyethylene,hoisted and fixed in repairs etc complete all as specified and as directed.
S&F PVC water storage tanks, 1000 lit capacity, rotational moulded polyethylene,hoisted and fixed in repairs etc complete.
S & F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as directed by Engineer-in-Charge as in repairs.
S&F in repair 15mm dia PVC connecton pipe 450mm ling with two nos PTMT fly nuts etc complete all as specified and directed.
M&L Vitreous china wash hand basin, white, flat back of size 550 mm x 400 mm including bracket, cutting for and pinning the ends of brackets or erecting stands also including brass chromium plated waste coupling 32mm dia, PVC flexible waste pipe of adequate length and dia and PVC connection 15mm size 450mm length with PTMT nuts, as in repairs, complete all as specified and as directed by Engineer-in-Charge.'
S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. with grating and union for discharge pipe all as specified and as directed by Engineer-In-Charge.
S & F in repair Vitreous china squatting pan of pattern Orissa Pattern of size 580x 440 mm white with 110mm bore PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor complete all as specified and as directed.
S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repairs PVC (SWR) bend with access door of any radius 110mm bore complete all as specified and as directed.
S&F in repairs PVC (SWR) bend with access door of any radius 75mm bore complete all as specified and as directed.
S&F in repair 110mm PVC (SWR) branch piece single (Y) equal or unequal complete all as specified and directed.
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) reducers complete all as specified and as directed.
M&L in repairs 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair of 15mm dia pillar taps fancy type, cast copper alloy, with capstan heads chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts screwed for iron pipe fixed complete all as specified and directed.
S & F in repair 15 mm bore CP fancy type bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. .
M&L for complete removal of existing treatment from external surface of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and directed
M&L for preparation of new plaster external surface of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primer,complete all as specified and directed.
Complete removal existing treatment and applying 1mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed.
M & L for preparation of new plastered/concrete surfaces of walls, providing one more coats of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified.
M & L for preparation of old decorated surfaces (plastered or unplastered) and applying two coat of white wash on the surfaces of ceiling complete all as specified and directed by Engr-in-Charge.
M & L for preparation of new plastered/concrete surfaces of ceiling, applying three coat of white wash on the surfaces of ceiling complete all as specified and directed by Engr-in-Charge.
M&L for preparation of wood and wood based materials old surface of any description exc. 10cm width and girth other wise described applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of wood and wood based materials new surface of any description and girth exc 10cm width or girth not other wise described and applying two coat of synthetic enamel paint over a coat of primer complete all as specified.
M&L for preparation of old wall surface and apply two coat of white wash on wall as directed by the Engineer-in-Charge.
M&L for preparation of old steel surfaces of any description, over 10cm in width or girth,not otherwise described applying one coat of synthetic enamel (ordinaty tint) all as directed.
Demolition of reinforcement Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., disposal of unserviceable materials, debris and rubbish to a distance as directed by the Engineer in Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/ loose soil all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed at a level not exceeding 1.5 M above the starting point.
M&L for Hard core, broken stone /boulders to gauge n exc 63 mm all as specified and directed.
M&L for cement concrete Type B2 1:2:4 (40mm graded aggregate) in surface channels and drains all as specified and directed.
M&L for RCC slab (nominal mix) 1:1.5:3 (20 mm graded aggregate) supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves all as specified and directed.
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat.as specified and directed.
M&L Precast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) complete all as specified and directed.
M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) cast in situ in cills and other similar bands, plinth courses, parapets, copings, hold fast ,bed plates and the like including use and waste of form work,weathering, slightly rounded or chamfered angles and throating all as specified.
M&L for Rendering 15 mm thick on stone masonry surfaces or surface in cement mortar 1:4 and finished even and smooth with using extra cement all as specified and directed.
M & L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
Removal of building Materials/ debris to a distance of 1 KM including loading, unloading , stacking and dumping/ levelling at the destination from work site . (Note: 1 Metric Tonne means One Load) complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2(using 40mm graded crushed stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed.
M&L for Walling of stone, regular coursed, well bonded, bedded and solidly heartedRandom rubble, uncoursed , polygonal rubble walling brought up to course built in cement mortar (1:6) complete all as specified and as directed.
Removing excavated materials (soil) n.exc. 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as direted.
Extra over Hammer dressing with maximum depression on face from straight edge held against the dressed surface of lime or sand stone n.exc 20mm complete all as specified and as directed.
M/L for raised pointing to random rubble stone masonary uncoursed or brought upto course in cement mortar (1:4) complete all as specified and directed.
M&L for PCC coping (1:2:4) type B-1 (using 20 mm graded aggregate stone aggregate) complete all as specified and as directed.
Loose filling with aggregates of guage 80 to 150 mm broken stone or boulders behind weep holes complete.
M&L for PCC ( 1:3:6) type C1 ( using 20mm graded crushed stone aggregates) including necessary form work as in precast bond stone sheet in CM ( 1:6) complete all as specified and as directed.
AGE E/M SCHEDULE PART - II Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Material & Labour for concealed Point wiring with two single core 1.5 sqmm (nominal area), FRLSH, ISI marked PVC Insulated unsheathed multistranded copper cable, 1100 volts grade including PVC Conduit of suitable size with all fittings and accessories including PVC rectangular board of suitable size, and FRLSH, ISI marked PVC insulated unsheathed single core multistranded copper cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one way switch including cutting chases not exc 10cm girth and making good disturbed surfaces complete all as specified and directed.
All as per Item No. 107 above but for one multi pin socket outlet, 5 Amps on independent board, complete all as specified and directed.
All as per Item No. 107 above but with FRLSH, ISI marked PVC insulated and unsheathed two single core multistranded copper cable of size 4.0 sqmm for one power point ,3 pin 15 Amps on independent board including FRLSH, ISI marked PVC insulated unsheathed single core multi-stranded copper cable of size 4.00 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F Switch socket combination 2 in 1 5A/16A, 3 pin 1 flush type universal complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed.
M&L ceiling rose, 3 terminals PVC/polycarbonate, isolated body complete all as specified and directed.
Supply and fixing LED batten fitting 18 Watt fixed to wall with 2 nos PVC block of suitable size complete all as specified and directed including taking down old unserviceable light fittings.
Material and labour for concealed sub main wiring with two single core 6.0 sqmm FRLSH, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLSH , ISI marked, PVC insulated multistranded copper conductor cable of size 6.0 sqmm green colour as earth lead including PVC conduit of suitable size including cutting chases not exc 10cm girth and making good disturbed surfaces complete all as specified and directed, including taking down unservicable one.(Note: two run of 6.0 sqmm cable , one run of earth wire of 6.0 sqmm and one run of PVC conduit shall be measured as one length).
Supply and fix MCCB Distribution board , 415 volts verticle triple pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 4 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed including taking down old unserviceable one.
Supply and fixing MCCB four pole 125 Amps, 415 Volts including taking down old one all as directed.
Supply and fix MCB Distribution board , 240 volts Single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed including taking down old unserviceable one.
Supply and fix MCB SPN, 240 Volt, 32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed iIncluding taking down old one.
Supply and fix MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed iIncluding taking down old one.
Supply and fixing PVC Exhaust fan 250 mm 230 Volts Ac single phase Complete all as specified and directed including taking down old unserviceable one.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
Supply and fixing LED security light 35 watt 230 V AC outdoor type with high pressure die cat aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP66 protection complete all as specified and directed
Supply, laying XLPE 50 Sqmm 3.5 Core insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable with stranded aluminum conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed
Excavation in trenches not exc 1.5 m wde and 1.5 m deep for taking out/laying of UG cable/GI pipe of any dismeter in hard/dense soil and getting out complete all as specified and directed
M & L for sand filing in treances for providing sand cushion for protection of UG cable complete all as specified and directed.
Supply and laying of fly ash bricks locally available of size 230x110x70 mm alying perpendicular of UG cable complete all as specified and directed.
M/S U.K ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .