| 1 | 1₹1.6 LAccepted-Finance BHAGWATI NAGAR JAMMU | 1 | Accepted-Finance found eligible | |
| 2 | 2₹1.6 L+₹6,480 (4.13%)Accepted-Finance | 2 | Accepted-Finance found eligible | |
| 3 | 3₹1.7 L+₹12,650 (8.07%)Accepted-Finance BYPASS NH NEAR SBI SIDHRA JAMMU | 3 | Accepted-Finance found eligible |
Tender Value
Refer Docs
EMD Value
₹3,600
Closing Date
17 Apr 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer MID Akhnoor/Nowshera
Office of the Executive Engineer MID Akhnoor/Nowshera
Repairs to electromechanical components with allied works at LIS Saranoo.
2021_IFC_122064_1
05/MID/AN
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
8 days
Akhnoor
Please refer Tender documents.
7 documents required · 7 mandatory
₹200
Yes
Executive Engineer MID Akhnoor/Nowshera
₹3,600
Yes
Office of the Executive Engineer MID Akhnoor/Nowsh
22 Apr 2021
8 Apr 2021
19 Apr 2021
8 Apr 2021
17 Apr 2021
9 Apr 2021
12 Apr 2021
180 days
Repair to 100 Kva voltage stabilizer installed at LIS Saranoo . The job involves disconnecting of the Voltage stabilizer from the main power supply (Incoming and Outgoing cables) . Opening and removing of the panel, loosening /dismantling of the top cover, nut and bolts. Lifting of inside transformer assembly with the chain pulley block for extraction of the complete unit. Dismantling/Extraction of the damaged /burnt coils ( 3 nos.) and shifting the damaged/burnt coils to workshop by using mechanical transport. Thereafter dismantling of the core assembly and extraction of the burnt copper wire with the help of manual labour and suitable tools/tackles. Rewinding of three coils by using new copper wire of the superior quality and shifting the coils back to site . Replacement of the rotor assembly (3 nos.) by way of p/f of new components, replacing all the damaged /burnt components. P/F of new panel accessories to panel of stabilizer by replacing the damaged with the new one. The job involves P/F of 1 No. MCCB of requisite capacity , 1 No. volt meter (Output Meter), Meter phase indicator, phase indicator lamps. Boiling of the T.oil in stabilizer by draining it out of the tank. Heating with heater coils to make it completely moisture free, filling it back after complete cleaning and drying of tank. Providing filling of 80 litre T.oil to make up for the deficit. Reinstallation of the stabilizer frame with transformer assembly. Lowering of complete unit in tank after p/f of shock proof gasket and body with nuts/bolts .Connecting power cables by p/f of new thimbles of the requisite capacity and testing on load . Complete job includes the cost of material, labour charges, transportation charges, hiring charges of tools / tackles required at site.
Repair of 40 HP 3 phase induction motor installed at LIS Saranoo. The job involves dismantling of motor from its installed position after disconnecting the power supply of all three phases. Dismantling the motor by unfastening the foundation nuts and bolts and also decoupling from the pump. Lifting the motor out of the pump house with chain pulley block with proper care to prevent any damage. Shifting the motor from LIS to workshop with the help of manual labour. mechanical transport to the workshop . Complete dismantling of the motor, extraction of rotor . P/F of both driving end and non driving bearing as per sample. Extraction of burnt winding from the stator, cleaning of stator with petrol .P/F of new winding wire of suitable gauge & size in the stator, varnishing the stator winding with superior quality of varnish. Drying the stator winding with hot air circulation process. Assembling of the motor and shifting back to L.I.S. Refitting the motor at its installed position and coupling with pump by way of lowering it with the help of chain pulley block, making of electrical connections, alignment with pump , testing of motor on full load. Complete job includes the cost of material, labour charges, hiring charges of tools & tackles, transportation charges. Complete job
Repair of horizontal centrifugal pumps 3.5 cusec discharge 18 mtr head of pumping Unit No. 1 installed at LIS Saranoo. De-coupling of pump from the motor and removing top cover of the HC pump, extracting the damaged internal impeller assembly together with bearing brackets and shifting the same to workshop by using manual labour and mechanical transport. Separating shaft, impeller and bushes . Rebuilding of impeller using good quality electrodes. Turning/machining of rebuild impeller on lathe machine for proper size. Repair to key ways .Providing/fabrication of both the bushes as per sample. Making necessary repairs to bearing housing. P/F new set of bearings as per sample. Assembling of the pump parts. Carriage / transportation of the pump assembly back from workshop to the site of installation at LIS. Fitment of pump along with replacement of rusted / damaged studs, gaskets, alignment setting at its position, p/f of gland packing, greasing work etc. Aligning & coupling the pump & motor. Complete testing & commissioning of the pumping unit on full load. Job includes cost of all material, transportation charges, head load and labour charges for skilled/semiskilled labour, hire charges for tools & tackles. Complete Job
Repairs to 200 Amp main switch installed at LIS Saranoo by way of dismantling it after disconnecting the power cables on both input and output side. Dismounting the main switch. Carriage / shifting of the main switch to workshop. Complete dismantling of the main switch. P/F of new bakelite strips/sheet of suitable rating and thickness. Replacement of damaged make and break clamp assembly as per sample. Replacement of damaged HRC fuses of requisite rating, copper thimbles and nut bolts etc. Adjustment of off / on switch/ arm. Assembling of the Main switch and shifting to the site of LIS. Fitting the main switch at designated place, connecting the cables by replacement of burnt / damaged thimbles on both input and output side. Testing the main switch on no load and then full load. Complete job includes cost of material , labour & transportation charges Complete Job
M/S RAGHUNATH MECHANICAL AND ELECTRICAL ENGINEERING WORKS
G S ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .