Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Fully Automatic Bio Chemistry Analyzer ( 1 pieces ) Technical Specifications 1/9 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Conformity to Standards - * Certification No and Date - * Performance Parameters Type of system Fully Open Random Access system * Purpose Should be capable of all routine
RequiredSTAT and special biochemical tests including specific proteins
Requiredtherapeutic drugs(TDM)
RequiredDrugs of abuse
RequiredImmunoturbidemtric assays and user definable applications in blood
Requiredserum
Requiredbody fluids
Requiredurine and equipment to be configurable as per requirements of consignee * Model type of Biochemistry Analyzer Bench top Type Bench top Type Type of samples serum
Requiredplasma
Requiredurine
RequiredCSF and any body fluid samples * Type of Assay End point
RequiredRate
RequiredKinetic turbidometric and bi chromatic assay * Throughput tests hour Photometric Tests with ISE module 200 or more 200 or more Throughput tests/hour Photometric Tests without ISE Module 200 or more 200 or more Calibration facility factor
RequiredLinear (one
Requiredtwo and multipoint)
RequiredExpone ntial
RequiredLogit- log
Requiredspline
RequiredNon linear factor
RequiredLinear (one
Requiredtwo and multipoint)
RequiredExponential
RequiredLogit-log
Requiredspline
RequiredNon linear Equipment must have self diagnostic tests with error message and online display Yes * 2/9 Equipment must be programmable for all test menus and state of the art work station should be upgradable by addition of ISE module Yes * Type of sample loading Sample tray Sample tray Equipment should have both internal and external probe cleaning/washing capacity Yes * Repeat facility repeat facility to be available for calibrator and control * Reagent refill message and monitoring facility Yes * Minimum number of test parameters on board at a time 50 * Minimum sample capacity at a time hint: Seller may select the value based on the number of samples that can be tested at a time and if it is any value betweem 35-49 select option of 35-49 and for other ranges also similar choices may be made 35 - 49 35 - 49 Minimum number of STAT samples at a time 39 * Out of range samples Should have pre post and auto dilution of samples and return capability for out of range samples * Probe dispensers Probe dispensors must have level detectors and must typically use between 2-25 µl of sample * Spectoral range in nm 340-700 * Wave length selection method Interference filter(With minimum 8 Interference filter(With minimum 8 3/9 interference filter) interference filter) Light source Halogen lamp low cost with long life * Life of lamp in hrs 1000 * Power consumption of lamp in VA 20 * Type of sample cups Reusable Reusable Number of sample cups provided with machine 1000 1000 QC program QC Programme with L-J graphs
RequiredPrint out of reports * The reaction cuvette must be reusable and durable Yes * System should have on board cooling system Refrigerated * DI water plant for the washing of the cuvettes/to avoid carry over and contamination Yes Yes Compatible on line UPS Yes Yes Back up time 1 hour 1 hour Data management software Equipment to be supplied with compatible programmable windows based comprehensive data processing and management system graphical user interface software
RequiredLM Capability complete back up of data base for calibration control and patient sample results
Requiredcapability for Bi- directional interfacing with LIS * Patient result storage capacity 15000 15000 Onboard cuvette washing & drying facility Yes Yes Photometeric Checking Yes * 4/9 of cuvettes before next reaction - Create Another field System should have facility for reading results on monitor and print out facility Yes * Reagents to be supplied with machine Creatinine
Requiredurea
Requireduric acid
RequiredTriglycerides
Requiredsugar
RequiredCholesterol
RequiredTP
RequiredCalcium albumin
RequiredSGOT
RequiredSGPT
Requiredalkaline phosphatase
RequiredBilirubin (Total & Direct) calibrator 5 ml - 4 and quality control 5ml -5 Nos each for normal and abnormal Creatinine
Requiredurea
Requireduric acid
RequiredTriglycerides
Requiredsugar
RequiredCholesterol
RequiredTP
RequiredCalcium albumin
RequiredSGOT
RequiredSGPT
Requiredalkaline phosphatase
RequiredBilirubin (Total & Direct) calibrator 5 ml - 4 and quality control 5ml -5 Nos each for normal and abnormal Reports Prinout of reports and full patient demographics to be available * System to be supplied with necessary pre requisites and start up kits normal and abnormal QC and calibrators Yes * Availability of RS 232 port/USB for data transfer Yes Yes Power supply 200-240V AC 50Hz Single phase * Reagents position More than 50 * Bar code reader for reagents Yes Yes Bar code reader for samples Yes Yes Refrigerator supplied with Analyzer No No Capacity of Refrigerator in L Not provided Not provided Star rating Not provided Not provided Type of Micro pipette Supplied Not provided Not provided Variable Micro pipette Supplied No No Seller must provide Yes * 5/9 original documentary proof of the date and place of manufacturing of supplied equipment Service manual and operating manual to be provided Yes * Warranty in years (including machine
RequiredDI Water Plant if provided
RequiredUPS
Requiredcomputer and printer) 3 3 Additional Parameters Sytem shall be supplied with a compatible desk top PC Yes Yes The PC shall be of reputed brand and name of brand to be specified - * Speed of processor in GHZ Greater than 3 GHZ Greater than 3 GHZ RAM in MB Greater than 512 MB Greater than 512 MB Hard disk drive capacity in GB Greater than 80 Greater than 80 Monitor TFT Digital color monitor TFT Digital color monitor Monitor size in inches 17 inches or more 17 inches or more Compatible operating system provided in PC Yes Yes Printer provided Yes Yes Type of printer Laser Printer Laser Printer The unit shall be capable of operating continuously in ambient temperature and relative humidity "Temp of 10 - 40deg C and humidity of 15-90%" * Startup kit
RequiredCalibrators
Requiredconsumables required in training the staff/Technician/Doctor s should be provided at the time of installation &Training Yes * The reaction cuvettes should be replaced at Yes * 6/9 free of cost when ever required during the warranty period Reports ISO Certification of Manufacturer ISO 13485 * ISO certification number and date - * Availability of test report from central govt/NABL/ILAC accredited lab covering all parameters Yes Yes Test report number if test report not available put NA - * Test report date if test report not available put NA - * Name of test lab if test report not available put NA - * Address of test lab if test report not available put NA - * Copies of all certifications and reports to be provided to buyer on demand at time of supplies Yes Yes * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents