Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC MES COLONY KUMBHIGRAM AIRPORT CACHAR ASSAM 788109 | KUMBHIGRAM | CACHAR | ASSAM | 788109 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹44.4 L+₹3.7 L (9.14%)Rejected-Finance 30 1 PULIN KHATICK ROAD TANGRA TANGRA KOLKATA WEST BENGAL 700015 | KOLKATA | WEST BENGAL | 700015 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹45.7 L+₹5.0 L (12.4%)Rejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹45.8 L+₹5.2 L (12.8%)Rejected-Finance 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | L4 | Rejected-Finance Other than Lowest Bidder | |
| 5 | L5₹46.2 L+₹5.5 L (13.7%)Rejected-Finance H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Jun 2023, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
CERTAIN REPAIR MAINTENANCE OF MOTORS PUMPS PANELS DOSING PUMPS AIR COMPRESSORS SWIMMING POOL PRESSURE FILTER UNITS AND OTHER CONNECTED WORKS UNDER GE NARANGI
2023_MES_597838_1
8877/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹80,000
Yes
3 Jul 2023
24 May 2023
14 Jun 2023
24 May 2023
12 Jun 2023
6 Jun 2023
Amount
Taking out carefully submersible pump of capacity up 6HP to 10HP any make and model from the borewell (350 ft-600ft depth) compelte with column pipe of size 50mm dia and other connected parts and lowering the same after necessary repair of the pump/development of borewell and replacement of nut bolts, gasket suitable size all per requirement complete all as specified and as directed. .Note- All T&P required shall be supplied by contractor without extra cost, repair work to be mesured and paid under relevant items.
Taking out carefully submersible pump of capacity up 12.5 to 25HP any make and model from the borewell UG sump by disconnecting electric connection, opening nuts & bolts from delivery line and other connected parts and lowering the same after necessary repair works of the pump set and replacement of nut bolts, gasket suitable size all per requirement complete all as specified and as directed. . Note- All T&P required shall be supplied by contractor without extra cost, repair work to be mesured and paid under relevant items.
M&L for 3 HP motor Strip opening of 3 phase AC submersible motor any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works.complete all as specified and as directed.
M&L for 6 HP motor Strip opening of 3 phase AC submersible motor any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works complete all as specified and as directed.
M&L for 10 HP motor Strip opening of 3 phase AC submersible motor any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works complete all as specified and as directed.
M&L for 20 HP motor Strip opening of 3 phase AC submersible motor any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works complete all as specified and as directed.
M&L for 40 HP motor Strip opening of 3 phase AC submersible motor any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works complete all as specified and as directed.
Taking out worn out bearing bush sleeves from the motor of capacity 6 to 10 HP and providing new stainless steel sleeve , turning and polishing of sleeve complete in all respect all as specified and directed.
Taking out worn out bearing bush sleeves from the motor of capacity 20HP to 40 HP and providing new stainless steel sleeve , turning and polishing of sleeve complete in all respect all as specified and directed.
Taking out worn out bearing bush sleeves from the motor of capacity 3 HP and providing new stainless steel sleeve , turning and polishing of sleeve complete in all respect all as specified and directed.
S & F in replacement of thrust plate alongwith disc of motor of capacity 6 HP to 10 HP complete all as specified and as directed.
S & F in replacement of oil seal of motor of capacity 3HP to 10 HP complete all as specified and as directed.
Dismantling the submersible pumping set bowl assembly any make and model for carrying out repair and replacement of worn out parts by strip opening with all parts such as bowl casing, impellers, pump shafts, lock collects, bushes neck rings etc and machine work such as welding, turning, re-facing where required and replacing of parts of pump of 6 to 9 stages, size up to 100 mm, for 6 HP to 10 HP capacity complete all as specified and as directed. Note:- Spares parts and their fixing shall be paid separately under the respective items of schedule.
S&F in replacement of pump shaft stainless steel suitable for submersible pump set up to 9 stages including threading cutting to size complete all as specified and as directed.
S&F in replacement of gun metal impellers suitable size for bowl assembly of submersible pumping set as per site requirement for suction discharge and intermediate bowls complete all as specified and as directed.
S&F CI casing suction/discharge/intermediate with studs complete all as specified and as directed.
S &F shaft seal of rubber complete all as specified and as directed.
S&F neck of bowls suction/discharge/intermediate complete all as specified and as directed.
S&F Gun metal bush of bowls complete all as specified and as directed.
S&F rubber bushes of bowls assembly of suitable size make and model for suction and discharge bowls complete all as specified and as directed.
S&F shaft coupling with key stainless steel of suitable sizes type make and model complete all as specified and as directed.
S&F middle /discharge bush, stainless steel of suitable size all as required at site complete all as specified and as directed.
S & f stainless steel impeller key complete all as specified and as directed.
S & F studs with nuts complete all as specified and as directed.
Mild steel GI column pipe for submersible pump 50 mm dia , heavy duty and 6 meter long duly welded flange on both sides incl rubber joint complete all as specified and as directed.
S & F Submersible flat cable of size 6 Sqmm 3 core 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor complete all as specified and as directed.
S & F Submersible flat cable of size 10 Sqmm 3 core 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor complete all as specified and as directed.
S & F Submersible flat cable of size 16 Sqmm 3 core 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor complete all as specified and as directed.
S & F in repair single core Cable with copper conductor PVC round sheathed (flexible) industrial cable of size 16 Sqmm 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor complete all as specified and as directed.
S & F in repair single core Cable with copper conductor PVC round sheathed (flexible) industrial cable of size 10 Sqmm 1100 volt grade copper conductor conforming to IS 694/1990 with latest ammendments from starter to motor complete all as specified and as directed.
Taking out the water sample from bore well water any type and carry out the test for 17 parameters as per indian standard drinking water specifications (BIS-10500:1991) from Govt approved lab complete all as specified and directed.
Taking out non clog submersible sewage pump set of capacity 12.5 HP to 25 HP from the sewage well and dismentaling the motor pump set at site of any capacity complete all as specified and as directed.
M&L for Strip opening of 12.5 HP to 15HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works complete all as specified and as directed.
Replacement of tungstun mechanical shaft seal for sewage pump application as per OEM complete all as specified and as directed.
Replacement of oil seal in non clog submersible sewage motor pump set of any rating as per OEM complete all as specified and as directed.
Replacement of DE roller bearing as per OEM complete all as specified and as directed.
Replacement of NDE ball bearingas per OEM complete all as specified and as directed.
Replacement of set of O rings complete all as specified and as directed.
Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turning and lathe work in wksp complete include testing and ciommissioning.
Supply and filling insulation oil as per OEM complete all as specified and as directed.
M&L for Strip opening of 25 HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works complete all as specified and as directed.
Replacement of oil seal in non clog submersible sewage motor pump set of any rating as per OEM complete all as specified and as directed.
replacement of DE roller bearing as per OEM complete all as specified and as directed.
Replacement of NDE ball bearingas per OEM complete all as specified and as directed.
Replacement of set of O rings complete all as specified and as directed.
Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turning and lathe work in wksp complete include testing and ciommissioning.
S&F MS chain closed type of size 12mm including round ring insert on every mtr include chain lock, Nuts & Bolts fixed on non clog sewage submersible pump complete all as specified and directed .
M&L disconnecting of monoblock pump set and motor of capacity up 0.5HP to 1HP, burnout winding wire, servicing and repairing/ replacement of impeller, shafts, shafts keys, bushes, fan blade, replacement of burnout winding wire with new winding wire of same gauge, cotton tape, varnish, ball bearing, bushes, gland packing, rubber gasket, capacitor, nuts & bolts complete and refixing the same on MS base frame on place and connecting to MS/GI piping line testing and commissioning all as specified and directed. Note: Rates for opening, transportation to workshop & back after necessary repairing works required such as welding, grinding and chamfering be included in the items rates.complete all as specified and as directed.
M&L disconnecting of monoblock pump set and motor of capacity 2 HP burnout winding wire, servicing and repairing/ replacement of impeller, shafts, shafts keys, bushes, fan blade, replacement of burnout winding wire with new winding wire of same gauge, cotton tape, varnish, ball bearing, bushes, gland packing, rubber gasket, capacitor, nuts & bolts complete and refixing the same on MS base frame on place and connecting to MS/GI piping line testing and commissioning all as specified and directed. Note: Rates for opening, transportation to workshop & back after necessary repairing works required such as welding, grinding and chamfering be included in the items rates complete all as specified and as directed.
Taking out Monoblock centrifugal electric 5 HP motor 3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without extra cost.
Taking out Monoblock centrifugal electric 7.5 HP motor 3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without extra cost.
Taking out Monoblock centrifugal electric 10 HP motor 3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without extra cost complete all as specified and as directed.
Taking out Monoblock centrifugal electric 25 HP motor 3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without extra cost complete all as specified and as directed.
Taking out Monoblock centrifugal electric 40 HP motor 3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without extra cost complete all as specified and as directed.
Taking out Monoblock centrifugal electric 50 HP motor 3 phase, 440 Volt from the exisitng foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge incl other allied items such as varnish tape, sleeve, greasing, beaaring, bushes etc of suitable size for following capacity of motor includeecessary repairing of rotor shafts if required and refixing after testing and commissioning complete all as specified and directed by Engr-in-Charge. Note- All T&P required shall be supplied by contractor without extra cost complete all as specified and as directed.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 100 HP complete all as specified and as directed.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 50 HP.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 40 HP complete all as specified and as directed.
Dismantling the Monoblock centrifugal Pump assembly any type or make for carrying out repair and replacement of worn out parts by strip opening of all parts such as impellers, pump shafts, lock collers, bearing/ bushes, gland rings , nuts & bolts etc and machine work such as welding turning, re-facing where required and replacing of defective parts up to pump capacity of 15 HP to 25 HP complete all as specified and as directed.
Supply & fix Rubber Insertion Sheet flange of thickness 4mm where required as per site requdirement, including cutting and making holes of sutable size complete all as specified and directed.
S&F Rubber coupling suitable for up to 25 HP motor including CI outer coupling and nuts & bolts including machining work for making shaft size complete all as specified and directed
S&F Rubber coupling suitable for 40 HP to100 HP motor including CI outer coupling and nuts & bolts including machining work for making shaft size complete all as specified and directed
S&F Star coupling including CI nuts & bolts suitable up to 15 HP Motors complete all as specified and directed.
Taking down existing old Non returning valve and supply & fix new NRV of size 150mm dia for suction complete all as specified and directed.
Taking down existing old Non returning valve and supply & fix new NRV of size 100mm dia for suction complete all as specified and directed.
Taking down existing old Stainer Valve and supply & fix new Stainer Valve of size 150mm dia for suction complete all as specified and directed include replacement of rubber sheet and nuts & bolts.
Taking down existing old Stainer Valve and supply & fix new Stainer Valve of size 100mm dia for suction complete all as specified and directed include replacement of rubber sheet and nuts & bolts.
Repairing of existing starter/panel by disconnecting existing burn out cable/ wiring complete and replaced with 1.5 Sqmm single core copper conductor or suitable size as per existing cable include replacement of Digital Volt meter, Digital Amp Meter alongwith CTs, relays, making connection, replacement of cable lugs of suitable size, repair/replacement of locking arrangement include painting with two coat of synthetic enamel paint complete all as specified and directed. Note : Repalcement of contractor, relay, MCCBs will be measured & paid seperately.
Repair to booster pump 1-2 stage of any make & model dismantling and reffting after complete overhauling by replacement stainless steel shaft keys GM gland intermediate plate with impellers bronze, relays complete all as specified and as directed.
Supply and fixing in repair DOL Starter suitable for 3 to 5 HP 440 Volt complete all as specified and as directed. Make :L&T/Havells/TC or equivalent.
Supply and fixing in repair DOL Starter suitable for 1 to 2 HP 230Volt complete all as specified and as directed. Make :L&T/Havells/TC or equivalent.
Taking out old UNSV starter from wall /panel and Supply and fixing Star Delta Starter in sheet metal enclosure with contractor & relays complete suitable for 40 HP motor 440 Volt. Make :L&T/Havells/TC or equivalent.
Supply only 3 Pole Power Contactor of 225 Amp, 415Volt coil voltage complete all as specified and directed as existing make: L&T MNX 225 or equivalent make in Siemens/Schneider
Supply only 3 Pole Power Contactor of 315 Amp, 415Volt coil voltage complete all as specified and directed as existing make: L&T MNX 315 or equivalent make in Siemens/C&S/Schneider
Supply only 3 Pole Power Contactor of 95/100 Amp, 415Volt coil voltage complete all as specified and directed as existing make: L&T MNX 95 or equivalent make in Siemens/C&S
Supply only 3 Pole Power Contactor of 70 Amp, 230 Volt coil voltage complete all as specified and directed as existing make: L&T or equivalent make in Siemens/C&S
Supply only 3 Pole Power Contactor of 32/40 Amp, 230 Volt coil voltage complete all as specified and directed as existing make: L&T or equivalent make in Siemens/C&S
Supply only Contactor ML/MNX or equivalent of 16/25Amps, 415 volts complete all as specified and as directed. make: L&T or equivalent make in Siemens/C&S
Supply only delay timer relay suitable for starter up to 50HP complete all as specified and as directed. make in Siemens/C&S/L&T
Supply only single phase preventer to protect motor for phase failure complete all as specified and direced.
S & F Indicator lamp LED type of RYB colour , 230 Volts complete all as specified and as directed.
M&L MCCB TP NL LT 415 volt 50 Hz, AC 125 amps 25 KA with thermal magnetic release for OL & SC protection Make : Siemens 3VL / Schneider NSX / Legrand DPX3 . Make : L&T /Legrand/Seimens
M&L MCCB TP NL LT 415 volt 50 Hz, AC 400 amps 25 KA with thermal magnetic release for OL & SC protection Make : Siemens 3VL / Schneider NSX / Legrand DPX3 . Make : L&T /Legrand/Seimens
M&L MCCB TP NL LT 415 volt 50 Hz, AC 250 amps 25 KA with thermal magnetic release for OL & SC protection Make : Siemens 3VL / Schneider NSX / Legrand DPX3 . Make : L&T /Legrand/Seimens
S & F Off load Change over switch 415 Volts front operated fixed in panel board include locking arrangements 4 pole of capacity 200 Amps complete all as specifed and directed. Make : L &T/ Havells/ Standard
S & F Off load Change over switch 415 Volts front operated fixed in panel board include locking arrangements 4 pole of capacity 400 Amps complete all as specifed and directed. Make : L &T/ Havells/ Standard
Taking down existing 2 to 4 core UG cable disconnect from panel board, proper dressing, replacement of cable lugs of appropriate size and refixing the same in porperly complete all as specified and directed.
Supply only Thermal Over load relay of rating 10- 40 Amps, 415 Volts, complete all as specified and directed make : L&T/Siemens/ C&S.
Supply only Thermal Over load relay of rating 20- 63 Amps, 415 Volts, complete all as specified and directed make : L&T /Siemens/ C&S.
M&L for replacement of watering pipe of 1 mtr length 8mm dia PVC threaded pipe both end nuts as per sample complete all as specified and as directed.
M&L for dismantling of 50HP pump set from foundation and replace the same with vibration plate of suitable size and making good disturbed surface as existing after servicing, greasing of the pump sets by dismantling, unscrewing nut bolt, cleaning, greasing and replacement of unsv bushes, Star coupling of suitable size including machining work complete, gasket, gland packing/water seals, nut bolts of suitable size and re-assembling the same in position and connect to the both end terminal circuit testing and commissioning complete all as specified and directed. (Note:- (a). Arrangement of necessary T&P items required for dismantling and reassembling pump motor set shall be deemend to be included in the quoted rate. (b). Cost of items be replaced as mentioned above shall be deemend to be included in the quoted rate.)
M&L for dismantling of 15 to 25 HP pump set from foundation and replace the same with vibration plate of suitable size and making good disturbed surface as existing after servicing, greasing of the pump sets by dismantling, unscrewing nut bolt, cleaning, greasing and replacement of unsv bushes, Star coupling of suitable size including machining work complete, gasket, gland packing/water seals, nut bolts of suitable size and re-assembling the same in position and connect to the both end terminal circuit testing and commissioning complete all as specified and directed. (Note:- (a). Arrangement of necessary T&P items required for dismantling and reassembling pump motor set shall be deemend to be included in the quoted rate. (b). Cost of items be replaced as mentioned above shall be deemend to be included in the quoted rate.)
Taking down flash mixer motor with gear assembly and churnig blades arangement of 1.5 HP, 3 Phase, 440 V by disconnecting from steel shaft & reductin gear arrangement. Repairing the motor by replacing the burnt winding, fixing the same after chanign suitable bushes, greasing, oiling, running and testing complete all as specified and as directed.
Taking down old UNSV light fittings and Supply and fixing LED flood light 100watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant include MS bracket , nuts & bolts fixed on wall or OHT pillar, or MS Structure complete with driver and lamp complete all as specified and directed.
Taking down old UNSV light fittings and Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Taking down old UNSV fittings and Supply and fixing post top lantern LED type 20watt 230 watt volts AC outdoor type with post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Taking down / up unserviceable XLPE LT cable of size up to 185 Sqmm to 240 Sqmm 3-1/2 core complete all as specified and as directed. (Note: Earth work to be measured and paid under relavent item of this schedule)
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade corss-sectional area 185 Sq mm 3.5core complete all as specified and as directed. (Note: Excavation & Thimbles to be measured and paid under relavent items of this schedule)
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade corss-sectional area 240 Sq mm 3.5core complete all as specified and as directed. (Note: Excavation & Thimbles to be measured and paid under relavent items of this schedule)
M & L for aluminium thimble of 25 Sqmm XLPE cable 3.5/4 core locally available, crimping with crimping tool properlly complete all as specified and as directed. (Note: Necessary nut, bolt and washers to be measured and paid under relavent item of this schedule)
M & L for aluminium thimble of 16 Sqmm XLPE cable 3.5/4 core locally available, crimping with crimping tool properlly complete all as specified and as directed. .(Note: Necessary nut, bolt and washers to be measured and paid under relavent item of this schedule)
M & L for aluminium thimble of 50 Sqmm XLPE cable 3.5 core locally available, crimping with crimping tool properlly complete all as specified and as directed. (Note: Necessary nut, bolt and washers to be measured and paid under relavent item of this schedule)
M & L for aluminium thimble of 70 Sqmm XLPE cable 3.5 core locally available, crimping with crimping tool properlly complete all as specified and as directed. (Note: Necessary nut, bolt and washers to be measured and paid under relavent item of this schedule)
M & L for aluminium thimble of 120 Sqmm XLPE cable 3.5 core locally available, crimping with crimping tool properlly complete all as specified and as directed. (Note: Necessary nut, bolt and washers to be measured and paid under relavent item of this schedule)
M & L for copper thimble of 16 Sqmm XLPE cable 3 core locally available, crimping with crimping tool properlly complete all as specified and as directed. (Note: Necessary nut, bolt and washers to be measured and paid under relavent item of this schedule)
M & L for copper thimble of 10 Sqmm XLPE cable 3 core locally available, crimping with crimping tool properlly complete all as specified and as directed. (Note: Necessary nut, bolt and washers to be measured and paid under relavent item of this schedule)
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand complete all as specified and as directed.
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
Taking down flocculator motor with gear assembly for rotating complete of 2 HP, 3 Phase, 440 V, with reduction gear and shaft, repairing the motor by replacing burnt winding with new copper winding of same gauge, repalcing worn out bearings and gears and fixing the same after oiling, greasing complete, running, testing complete all as specified and directed. Note:-New bearing shall be of existing size and of existing make.
Taking down flocculator motor with gear assembly for rotating complete of 2 HP, 3 Phase, 440 V, with reduction gear and shaft, repairing the motor by replacing bearings, gears, fixing the same, after oiling, greasing complete, running, testing complete all as specified and as directed.
Material and labour PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed.
M&L for taking out existing filter media from Iron removal plant or Pressure fillter of cap 6000 GPH of any description carefully and removing out to distance 50 Mtrs away from pump house, including cleaning, washing inside of filter including painting Inside & Outside, replacement of UNSV PVC threaded hose pipe, rubber washers, Nuts & Bolts , testing and comissioning complete all as specified and directed.
S&L and leveling gravel of size 20 x 12mm thickness as per OEM design complete all as specified and directed.
S&L and leveling gravel of size 12 x 6mm thickness as per OEM design complete all as specified and directed.
S&L and leveling gravel of size 6 x 3mm thickness as per OEM design complete all as specified and directed.
S&L and leveling gravel of size 3 x 1.5mm thickness as per OEM design complete all as specified and directed.
S&L and leveling Ferrimenix (MNO2) compound as per OEM design complete all as specified and directed.
S&L and leveling fine sand of size 0.45mm to 1mm as per OEM design complete all as specified and directed.
Checking of Dosing Pump regurlarly basis for a period of six months installed at different locations for entire period of completion for smooth fucntioning of plants, find out defect and rectify the defect immediately when found in plants all specified as directed for complete contract period. Note :- (i) Spare parts shall be ,easured and paid for separately. (ii) In case, payment shall be made in part period, rate shall be worked out on proportional basis
Supply only Rotor assembly with bearing brackets & tolerance ring complete all as specified and as directed. Make Declibac Part No PMBRPL2
Supply only Single Head Feed rate control with shaft complete all as specified and as directed. Make Declibac Part No FC5040D
Supply only No. 7 Pump Head (Ferrules 1/4" & Duckbill included) complete all as specified and as directed. Make Declibac Part No UCPH7FD
Supply only No 7 Pump Tube Part No MCCP207 complete all as specified and as directed.
Supply only Injection Check Valve 3/8" complete all as specified and as directed. make Declibac Part No MCINJ38
Supply only Weighted suction line strainer 3/8"complete all as specified and as directed. make Declibac Part No ST 138
Supply only 3/8" White suction /discharge tubing chlorine grade complete all as specified and as directed.
Supply only Check valve duckbill Only (Set of 5) complete all as specified and as directed. Make Declibac Part No MCCVDBO
Supply only Connecting Nut 3/8" Part No MANUT00 complete all as specified and as directed.
Supply only Roller assy complete all as specified and as directed. Make Declibac Part No MC3ASYD (Set of 4 items)
Supply only Motor 230V, 50 Hz 0.2HP as per sample complete all as specified and as directed.
Supply only Ferrule 1/4" (Packing of 24 Pcs) complete all as specified and as directed.
Supply only STEQUA 411 AE refill (S411AE) containing upto 80% chlorine suitable for inline Dosing system complete all as specified and as directed. Model ADS Pro.
S&F as in repairs 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches with all fittings fixed to walls complete all as specified and directed. Make: FINOLEX, PRINCE, SUPREME, KAMPLAST
Taking down old UNSV Booster Pump and Supply and Fix New inline Booster Pump 5 stage alongwith Air cushion Tank and pressure control relay of rating 0.1 Bar to 6.0 Bar of Make Denfoss as existing complete of capacity 0.75 HP including pressure gauge, making electrical connection, testing and cmmissioning complete all as specified and directed. Make : KSB/CG/Grandfoss/Kirloskar
Taking down old UNSV Booster Pump and Supply and Fix New inline Booster Pump 5 stage alongwith Air cushion Tank and pressure control relay of rating 0.1 Bar to 6.0 Bar of Make Denfoss as existing complete of capacity 0.5 HP including pressure gauge, making electrical connection, testing and cmmissioning complete all as specified and directed. Make : KSB/CG/Grandfoss/Kirloskar
Taking down booster pump and Repair & servicing to booster pump 4-6 stage of any make dismantling and refftting after complete after rewinding of motor with suitable size winding wire, overhauling by replacement of stainless steel shaft, keys, GM bush, gland, air filling, pressure relay calibration, intermediate plate with impellers bronze complete all as specified and as directed.
Supply and fixing inrepair water tight IP-66 tricolour fountain Metal body LED light fittings 9W, 230V complete include making connection with water proof wire alongwith driver as existing complete all as specified and directed.
Supply only Over all apron for handling of chlorine gas / liquid for operator including suitable Mask & Rubber gloves complete all as approved or directed by Engr-in-Charge.
Supply and fixing GI wiremesh of 4mm gap, 300mm dia circular shaped double folded fixed to suitable MS circular frame connected through 20mm dia, GI pipe light grade of 2.5 to 3.5 mtr, circular frame and extended GI handling pipe duly painted by one coat of synthetic enamel paint of desired and directed tint over a coat of red oxide,complete all as specified and as directed.
Supply in fix in repair single phase monoblock pumpset 1HP consisting of motor and pump complete with DOL starter including fixing complete all as specified and directed. Note : old Pumpset to be deposited in MES store.
Supply in fix in repair single phase monoblock pumpset 1.5 HP consisting of motor and pump complete with DOL starter including fixing complete all as specified and directed. Note : old Pumpset to be deposited in MES store.
Opening, dismentaling of Rotary Air blower /compressor any type of capacity 700 CuM /Hrs Pressure 6500WG fitted in various location, servicing, repairing and replacement of parts, calibration, oil replacement, Complete all as specified and as directed by Engineer –in-Charge. Note : Replaced parts to be measured and paid seperately under relevant items. (WTP, Swimming Pool Filtration plant & STP)
Supply only Piston ring set complete all as specified and as directed.
Supply only Piston with Gudgeon pin complete all as specified and as directed.
Supply only Big end bearing complete all as specified and as directed.
Supply only Small end bearing complete all as specified and as directed.
Supply only Main bearing complete all as specified and as directed.
Supply only Pressure release valve complete all as specified and as directed.
Supply only Saffety valve complete all as specified and as directed.
Supply only Gasket Set complete all as specified and as directed.
Supply only V Belt as existing complete all as specified and as directed.
Supply only Compressor Oil complete all as specified and as directed.
Supply only Pressure pipe complete all as specified and as directed.
Supply only Cylinder liner complete all as specified and as directed.
Supply only Ball valve 20mm complete all as specified and as directed.
Supply only PVC threaded pipe 15mm dia include clips as per sample for IRP filters.complete all as specified and as directed.
Opening, dismentaling of compressor any type of capacity 3.5 Kg/Sq Cm fitted in various location, servicing, repairing and replacement of parts, calibration, oil replacement, complete all as specified and as directed. Note : Replaced parts to be measured and paid seperately under relevant items.
Supply only Piston ring set complete all as specified and as directed.
Supply only Piston with Gudgeon pin complete all as specified and as directed.
Supply only Big end bearing complete all as specified and as directed.
Supply only Small end bearing complete all as specified and as directed.
Supply only Main bearing complete all as specified and as directed.
Supply only Pressure release valve complete all as specified and as directed.
Supply only Saffety valve complete all as specified and as directed.
Supply only Gasket Set complete all as specified and as directed.
Supply only V Belt as existing complete all as specified and as directed.
Supply only Compressor Oil complete all as specified and as directed.
Supply only Pressure pipe complete all as specified and as directed.
Supply only Cylinder liner complete all as specified and as directed.
Supply only Ball valve 15mm complete all as specified and as directed.
Supply only PVC threaded pipe 15mm dia include clips as per sample for IRP filters complete all as specified and as directed.
Design, fabrication, supply, installation, testing and commissioning of the following Indoor type LT panel suitable to be mounted on the floor/cable duct/ wall as per site requirement using M.S channel frame work, with cable entry from bottom/top as per drawing coordination by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 2 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-42, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, Aluminium bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc.., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, including comprising of following switchgear and accessories complete in all respects. (WTP Pump House) Incoming (a) On load change over switch 315Amps 4 Pole, 415V front handle cubical panel mounted type complete all as specified and directed. -01 No (b) MCCB Four pole-315A, 415V, 36 KA breaking capacity with adjustable thermal setting based overload and short circuit release Complete in all respects-1 No (c) 500 Amp copper bus bars for phase and neutral with bus bar insulators, heat shrinkable PVC sleeves etc. complete. (d) Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, having feature Voltage, Amp, Kwh, Pf, KW, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of any approved make meeting technical specification of above MFM complete in all respect -01 No (e) 400/5A current transformers of class 1.0 and suitable VA burden for metering-01 Set. (f) RYB indicating lamps of LED module with toggle switches-01 Set. (g) 6 A, 230V ,SP MCB's for the protection of measuring instrument and control wiring-1 Set.
Design, fabrication, supply, installation, testing and commissioning of the following Indoor type LT panel suitable to be mounted on the floor/cable duct/ wall as per site requirement using M.S channel frame work, with cable entry from bottom/top as per drawing coordination by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 2 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-42, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, Aluminium bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc.., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, including comprising of following switchgear and accessories complete in all respects. (Main Pump House) Incoming (a) On load change over switch 630Amps 4 Pole, 415V front handle cubical panel mounted type complete all as specified and directed. -01 No (b) MCCB Four pole-630A, 415V, 36 KA breaking capacity with adjustable thermal setting based overload and short circuit release Complete in all respects-1 No (c) Motor Protection Automation Phase Sequence Corrector 400 Amps with single phasing protection, Under Voltage, Over Voltage, Phase reversal with facility to change over from automatic to manual with contactors etc - 01 No. Make: L&T/ABB/universal switch gear control. (d) 1000 Amp copper bus bars for phase and neutral with bus bar insulators, heat shrinkable PVC sleeves etc. complete. (e) Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, having feature Voltage, Amp, Kwh, Pf, KW, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM any approved make meeting technical specification of above MFM complete in all respect -01 No (f) 600/5A current transformers of class 1.0 and suitable VA burden for metering-01 Set. (g) RYB indicating lamps of LED module with toggle switches-01 Set. (h) 6 A, 230V ,SP MCB's for the protection of measuring instrument and control wiring-1 Set.
Design, fabrication, supply, installation, testing and commissioning of the following Indoor type LT panel suitable to be mounted on the floor/cable duct/ wall as per site requirement using M.S channel frame work, with cable entry from bottom/top as per drawing coordination by EIC with removable gland plates with required knock-outs for incoming and outgoing cables. Panel shall be fabricated out of CRCA sheet 2.00 mm thick steel folded and braced as necessary to provide a rigid support for all components, totally enclosed and degree of protection shall not be less than IP-42, multi-tier cubicle type formation with front hinged lockable doors for the individual feeders/compartments, preparation of surface and treatment by seven tank process, powder coated with approved colour for not less than 50 microns and all doors and covers shall be fully gasket using good quality EPDM gasket and /or rubber strips, and to provide good quality locking arrangement, durable door opening & closing mechanism, Aluminium bus bars for three phases and neutral, bus bar insulators, heat shrinkable PVC sleeves etc.., with necessary interconnections as specified in Technical specifications for electrical & mechanical works, including comprising of following switchgear and accessories complete in all respects. (Peer Baba coloney, Jorabhat Pump House, Madhuban Pump House) Incoming (a) On load change over switch 100Amps 4 Pole, 415V front handle cubical panel mounted type complete all as specified and directed. -01 No (b) MCCB Four pole-100A, 415V, 25 KA breaking capacity with adjustable thermal setting based overload and short circuit release etc. Complete in all respects-1 No (c) 200 Amp copper bus bars for phase and neutral with bus bar insulators, heat shrinkable PVC sleeves etc. complete. (e) Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, having feature Voltage, Amp, Kwh, Pf, KW, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM any approved make meeting technical specification of above MFM complete in all respect -01 No (f) 100/5A current transformers of class 1.0 and suitable VA burden for metering-01 Set. (g) RYB indicating lamps of LED module with toggle switches-01 Set. (h) 6 A, 230V ,SP MCB's for the protection of measuring instrument and control wiring-1 Set.
M/s DAS AND CO
S. R. TRADING
ADITI CONSTRUCTION CO.
SHANKAR ENTERPRISE
PURBANCHAL BUILDERS
DEE PEE ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .