Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.4 L+₹68,988.48 (2.25%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹31.5 L+₹76,218.10 (2.48%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹31.7 L+₹96,072.40 (3.13%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹31.9 L+₹1.2 L (3.82%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹35.8 L
EMD Value
₹71,600
Closing Date
11 Apr 2023, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
SPECIAL REPAIRS TO BLDG NO 91A, 91F AND 91G AT THIMMAIAH LINE UNDER GE MCEME AT MCEME UNDER GE MCEME SECUNDERABAD
2023_MES_585513_1
GE/MCEME/TOK/58 OF 22-23
Open Tender
Civil Works
Item Rate
180 days
GE MCEME SECUNDERABAD
Class D category a(I)
9 documents required · 9 mandatory
₹500
GE MCEME SECUNDERABAD
₹71,600
Yes
1 May 2023
13 Mar 2023
13 Apr 2023
13 Mar 2023
11 Apr 2023
29 Mar 2023
Amount
Dismantling of asbestos cement (corrugated,semi corrugated etc.) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws' complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium snap grid of 605x605mm frame work for ceiling including Hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long omplete all as specified and directed by Engineer-in-Charge.
M&L for 6 to 7 mm thick Gypsum board panels 600x600mm with PVC laminated on one side and aluminium foil on another side suitably placed in false ceiling grid made of aluminium GI/MS all as specified and as directed. Note: Aluminium grid will be measured and paid separately complete all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description and in any position not otherwise provided for, complete all as specified and directed by Engineer-in-Charge.
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates, Fe410-W (Gde-E-250) quality-A, complete all as specified and directed by Engineer-in-Charge.
S& F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, etc complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of old painted steel surfaces of any description over 10 cm in width or girth andapplying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling stone slabs and tiles laid dry and pointed of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, 25mm thick, type B0 (12.5mm graded stone agg) as as floor finishes complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles 450x300x7mm thick, vertical surfaces such as dados, including 10mm thick rendering in CM 1:3 to receive tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match, etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking down chowkhats or frames not exc 1.5 sqm each(without taking off shutters from the frames), etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking down,Chowkhats or frames exc. 1.5 sq. m and n.exc. 4 Sqm each, but with shutters (without taking off shutters from the frames), complete all as specified and directed by Engineer-in-Charge.
S/F pressed steel door frame 125 x 60mm with one or more rebats including fixing lugs, hinges, lock strike plate complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping, filling in door frame complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinges extruded aluminium alloy with brass/bronze hinge pin in lieu of mild steel min , complete all as specified and directed by Engineer-in-Charge.
S/F 150mm size aluminium anodised handles, fabricated type , complete all as specified and directed by Engineer-in-Charge.
S & F 35 mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on face is covered with decorative face veneer both sides , complete all as specified and directed by Engineer-in-Charge.
S&F of 35mm thick Second class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc. divided in to square with plain chamfered or rounded mitred and rebated sash bars, any numbers, edges of framing plain chamfered or , complete all as specified and directed by Engineer-in-Charge.
S/F Stainless Steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless Steel wire staples along with frame work of windows / ventilators with all necessary arrangements, complete all as specified and directed by Engineer-in-Charge.
S&F 200mm long Al anodised or matt finished barrel tower bolt of extruded section , complete all as specified and directed by Engineer-in-Charge.
S & F for Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 250 mm, complete all as specified and directed by Engineer-in-Charge.
S & F for Floor door stopper of brass body and tongue, anodised,with hard drawn steel spring, fixed in floor, Overall length of cover plate 140 mm,etc complete all as specified and directed by Engineer-in-Charge.
S&F 300mm long MS ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed by Engineer-in-Charge.
S&F in rep Chromium Plated curtain rod/drapery rod 20mm dia of approved pattern and quality with decorative stainless steel backets of approved quality, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated surface of wood or wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enemal paint over a coat of pink primer, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F prepainted steel windows/ventilators ( ECO–4000 Series Windows (Double Rebate Windows) or equivalent) fabricated from roll framed sections made of galvanized steel colour coated/powder coated (Base steel as per IS-513 “D” quality galvanized as per IS-277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm. Sections for Frame should be of 72x55mm, Section for Mullion should be of 72x50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12x12mm, and Section for Fly Mesh should be of 40x20mm Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter including SS Pivot Hinges–1 set, Seccolor Handle & Seccolor Stay and 4mm Plain Float Glass and Stainless Steel 32 gauge Fly mesh of 25 holes per SqCM and powder coated Grill made of 10mm sq. MS Bars welded at 150mm c/c, 6x12mm MS flat and fixed to window frame with screws , complete all as specified and directed by Engineer-in-Charge. (Make : NCL/TATA/Equivalent)
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge.
M&L brick work with Fly Ash bricks old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Taking down of cement plaster on brick or stone walls,/ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement) with water proofing compound, complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-in-Charge.
M&L for Two coats of Distempering with oil emulsion distemper on newly plastered surfaces of walls over two coat of wall care putty over a coat of alkali resistance primer including preparation of wall surfaces, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation newly plastered surfaces of walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
M&L for prepration old surfaces of walls and apply two coat of cement base paint, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces of walls and applying one coat of oil bound distemper over a coat of primer over two coat of wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n. exc 30cm high with synthetic enamel paint of painted wall surfaces, complete all as specified and directed by Engr-in-Charge. (Note : Work to be carried out from ground floor to fourth floor of bldg height)
Supply only Integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, etc complete all as specified and directed by Engineer-in-Charge.
M & L 75mm thick PCC 1:3:6 type C-2 using 40mm graded aggregate as in plinth protection, complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping, including form work, complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete of any description in any position (Reinforced), complete all as specified & directed by Engr-in-Charge.
M&L RCC 1:2:4 type B1 (using 20 mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge.
M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, TMT bars,etc, complete all as specified and directed by Engineer-in-Charge.
M&L mild steel TMT bars 8mm dia and over cut to length bent to shape required including cranking, bending spirally including mild steel wire not less than 0.9mm dia or securing with clips for stirrups complete all as specified and directed by Engineer-in-Charge.
Form work to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. Rough finished surfaces of concrete flat complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china Orissa pattern squatting pan 580 x 440mm with integeral foot rests including P or S trap, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous China wash hand basin of size 550 x 400mm white flat back including chromium plated pillat tap, waste coupling, including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs for PVC low level flushing cistern, white, 10 ltr. Capacity, complete with all internal accessories & fixed to wall & making good to wall surfaces incl. taking down existing flushing cisterns Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC connection pipe 15mm bore 600mm long with PVC nutsComplete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm dia bib taps, chromium plated fancy type, cast copper alloy with fancy type handle , screwed down , screwed for iron pipe or for brass ferrule with wall flange Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs CP 15mm, stop valves/ angle cock, cast copper alloy with crutch or butterfly handle, screwed down, high pressure, screwed both ends for iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in rep CP brass tubular towel rail 600mm long 20mm dia 'D' type in repairs complete all as specified and as directed by Engineer-in-Charge.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs, PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by Engineer-in-Charge.
S&F 1000 Ltr capacity of rotational moulded polythylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position including dismantling all as specified in SSR Part-I), etc complete all as specified and as per directed by Engineer-in-Charge.
S&F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and as directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 15 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
Taking up or down steel tubing & connections, 20 mm dia, etc complete all as specificed and as per directed by Engineer-in-Charge.
S&F GI Tubes, 'medium grade' with all fitting & fixed complete to walls & ceilings or laid in floors of 15mm bore complete all as specified and as directed by Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required of brick walls and pointed in cement mortar 1:3 for concealed water tubing etc cutting not exc 10 cm girth, complete all as specified and directed by Engineer-in-Charge.
S&F GI Tubes, 'medium grade' with all fitting & fixed complete to walls & ceilings or laid in floors of 20mm bore complete all as specified and as directed by Engineer-in-Charge.
M&L Solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per manufacturers instruction complete all as specified and as directed by Engineer-in-Charge.
M&L Factory made solid panel laminated PVC door shutter 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitalble PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing complete all as specified and as directed by Engineer-in-Charge.
S&F in rep Stainless Steel soap dish, any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed by Engineer-in-Charge.
S&F in rep brass chromium plated shower rose 125 mm size with or without swivel joints , any size including fixing to steel pipe or union, complete all as specified and directed by Engineer-in-Charge.
S&F in rep PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge.
S&F in rep PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge.
M&L for bends PVC (SWR) 110 mm dia of any radius,fixed to walls/laid in floor , complete all as specified and directed by Engineer-in-Charge.
M&L for bends PVC (SWR) 75mm dia of any radius,fixed to walls/laid in floor , complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) vent cowls 110mm dia complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in hard / dense soil n.exc 1.5M wide and n.exc 1.5M in depth for foundation complete all as specified and as directed by Engineer-in-Charge.
M&L salt glazed stoneware drain pipes laid in trenches & jointed as specified of 150mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L Concrete bed to drain pipes of 150mm dia bore in PCC 1:3:6 type C-2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested including conection to man hole complete all as specified and as directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, 150mm dia.complete all as specified and as directed by Engineer-in-Charge.
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs set in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/ dense soil, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base etc., complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes, complete all as specified and as directed by Engr-in-Charge.
M & L chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments, complete all as specified and as directed by Engr-in-Charge.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C0 (Using 12.5 mm graded stone aggregate) providing precast cement concrete louvres and jallies,25 mm thick (mea sured solid), including all mould- ings but excluding frame (Pre cast frame shall be measured separately and paid for under item 04032) set in cm 1:4 complete all as specified and shown on drgs.complete all as specified and as directed by Engineer-in-Charge.
Excavating over areas, n exc 1.5m deep and getting out hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in surface channelor drain, complete all as specified and directed by Engineer-in-Charge.
M&L cement type C2 1:3:6, using 40mm aggregate in surface channel and drains etc., complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit concealed wiring in walls/PVC conduit on wall including Tee, Junction boxes and provision of 2.0mm thick MS terminal boxes duly painted with red oxide metal primer and covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 98 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 98 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 98 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 98 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of socket outlet 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch socket combination 2 in 1 multipurpose 3 pin 5/15 amps flush type complete all as specified.
Supply and fixing of electronic ceiling fan regulator stepped 2M type heavy duty suitable to work on 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed Submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing complete all as specified and as directed by Engineer-in-Charge. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length.
Supply and fixing LED wall mounted batten light fitting with polycarbonate housing and integrated electronic driver 1x 20W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fixing LED wall mounted batten light fitting with polycarbonate housing and integrated electronic driver 1x 10W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fixing LED light fitting 1x 9W/1x 10W bulk head luminairs including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED energy efficient security light fitting of capacity of 40 W including suitable dia GI pipe bracket for fixing the light on wall complete all as specified and as directed by Engineer-in-Charge. NOTE : GI bracket, clamp, nut and bolt etc will be measured in separate item.
Supply and fixing galvanised iron tube bracket of 40 mm dia light grade and 1.2 m length for fixing bldg security light, with all fixing arrangement including necessary clamp, nut and bolts etc as required size all as specified and directed
Supply and fixing lamp holder insulated body with back plate for angle batten fitting fixed with round block including LED bulb 9 W non dimmable type complete all as specified and directed
Disconnecting and removing fan of any sweep any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine and replacement of split pins/ cotter pins and check nuts etc overhauling, lubricating , reassembling, refixing in original position with new down rod and clamp complete all as specified.
M&L for fixing GI tubes,' medium grade ' galvanised of size 20 mm dia, with all fitting and fixed for hanging ceiling fans including cutting, nuts and bolts to fix at hooks and fans including spray paint after 2 coats of red oxide paint complete all as specified and directed.
Rewinding of burnt ceiling fan of 1200 / 1400mm sweep of any make and model with supper enameled copper wire of suitable size and using insulating material of good quality, varnishing complete all as specified and directed by Engineer -in-charge.
Supply only Sealed ball bearing suitable for ceiling fan of any size(set of two) complete all as specified and as directed by Engineer-in-Charge.
Supply only Rotar shaft suitable for ceiling fan of any size complete all as specified and as directed by Engineer-in-Charge.
Supply only Rubber bushes with MS clamp,bolt and nut suitable for ceiling fan of any size complete all as specified and as directed by Engineer-in-Charge.
Supply only Fan condensor 2.5 mfd suitable for ceiling fan of any size complete all as specified and as directed by Engineer-in-Charge.
S & F Exhaust fan metal body , 230 mm sweep , single phase ,50 HZ , with louver and connecting up with and incluiding provision of PVC insulated copper flexible cord of size 23/0.019, 3 core from ceiling rose to connection of exhaust fan and including material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface complete all as specified and as directed by Engineer-in-Charge. Note : cost for material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface will be measured and paid in seperate item.
M&L for making hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface including cement work and painting to the wall matching to the existing complete all as specified and as directed by Engineer-in-Charge.
Materials and Labour for one coat of spray painting, super glossy to fan body including blades with white colour, after removing of loose paint, rust dust and oily particle by scraping , complete all as specified and as directed by Engineer-in-Charge.
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 25 Sqmm , 3.5 core complete all as specified and as directed by Engineer-in-Charge.
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid complete all as specified and as directed by Engineer-in-Charge.
Supply and lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm
Supply and fixing from LT pole/Panel board to MCCB DBs, the medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and as directed
S & in replace of Vertical type MCCB TPN DB 4 way double door suitable for MCCB 63 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed.
Supply and replace MCCB 4P, 415V,16KA, 63 amps suitable for Vertical MCCB DB complete all as specified and as directed by Engineer-in-Charge.
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and as directed by Engineer-in-Charge.
Supply and replace MCB double door DB SPN 4 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB SPN 40 Amps 240 volts for fixing on MCB DB complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.)complete all as specified and as directed by Engineer-in-Charge.
SAI RUPA CONSTRUCTIONS
K LAKSHMAN SINGH AND CO
RAM CHARAN CONSTRUCTIONS
NEWS CONSTRUCTIONS
LAKSHMI NARASIMHA ENTERPRISES
harshraj and co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .